Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation. These devices typically include: smart grid electronics, air conditioning, heating, lighting, power transformer cooling fans, station battery chargers (DC) and standard wall socket outlets. This double pole voltage transformer generates an output of 230 Volt.
Technical Specifications:
UGZT..D2 | UGZT..C1 | UGZT..E6 | |
---|---|---|---|
Application | Switchgear, Transformer statio | Switchgear, Transformer station | Switchgear, Transformer station |
Standard | IEC61869-3, VDE 0414 | IEC61869-3, VDE 0414 | IEC61869-3, VDE 0414 |
Rated insulation voltage | Up to 12/28/75kV | Up to 12/28/75kV | Up to 24/50/125kV |
Maximum rated primary voltage | 11kV | 11kV | 22kV |
Rated voltage factor | 1,2 x UN for 8h, 1,2 x UN continuous | 1,2 x UN for 8h, 1,2 x UN continuous | 1,2 x UN for 8h, 1,2 x UN continuous |
Secondary voltages | 230V, other options available on request |
230V, other options available on request |
230V, other options available on request |
Rated output | See teble 2 | See teble 2 | See teble 2 |
Rated frequency | As required For example 50-60Hz |
As required For example 50-60Hz |
As required For example 50-60Hz |
Insulation class | E | E | E |
Secondary terminals | Protected with a sealable cover, degree of protection IP 20 |
Protected with a sealable cover, degree of protection IP 20 |
Protected with a sealable cover, degree of protection IP 20 |
Ordering Specifications (50/60Hz):
UIN |
UGZT..D2 |
UGZT..C1 |
UGZT..E6 |
---|---|---|---|
1,5kV | 2000VA | 750VA | 4000VA |
3kV | 2000VA | 750VA | 4000VA |
6,3kV | 1500VA | 750VA | 3500VA |
6,6kV | 1500VA | 750VA | 3500VA |
7,2kV | 1300VA | 600VA | 3200VA |
10kV | 1300VA | 600VA | 3200VA |
11kV | 1300VA | 600VA | 3200VA |
13,8kV | - | - | 3000VA |
17,5kV | - | - | 2000VA |
20kV | - | - | 2000VA |
22kV | - | - | 2000VA |
Dimensions
Wiring diagram:
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Auxiliary power supply systems are needed to ensure the energy supply for the operation of primary or secondary devices in a station, switchgear or substation. These devices typically include: smart grid electronics, air conditioning, heating, lighting, power transformer cooling fans, station battery chargers (DC) and standard wall socket outlets. This double pole voltage transformer generates an output of 230 Volt.
Technical Specifications:
UGZT..D2 | UGZT..C1 | UGZT..E6 | |
---|---|---|---|
Application | Switchgear, Transformer statio | Switchgear, Transformer station | Switchgear, Transformer station |
Standard | IEC61869-3, VDE 0414 | IEC61869-3, VDE 0414 | IEC61869-3, VDE 0414 |
Rated insulation voltage | Up to 12/28/75kV | Up to 12/28/75kV | Up to 24/50/125kV |
Maximum rated primary voltage | 11kV | 11kV | 22kV |
Rated voltage factor | 1,2 x UN for 8h, 1,2 x UN continuous | 1,2 x UN for 8h, 1,2 x UN continuous | 1,2 x UN for 8h, 1,2 x UN continuous |
Secondary voltages | 230V, other options available on request |
230V, other options available on request |
230V, other options available on request |
Rated output | See teble 2 | See teble 2 | See teble 2 |
Rated frequency | As required For example 50-60Hz |
As required For example 50-60Hz |
As required For example 50-60Hz |
Insulation class | E | E | E |
Secondary terminals | Protected with a sealable cover, degree of protection IP 20 |
Protected with a sealable cover, degree of protection IP 20 |
Protected with a sealable cover, degree of protection IP 20 |
Ordering Specifications (50/60Hz):
UIN |
UGZT..D2 |
UGZT..C1 |
UGZT..E6 |
---|---|---|---|
1,5kV | 2000VA | 750VA | 4000VA |
3kV | 2000VA | 750VA | 4000VA |
6,3kV | 1500VA | 750VA | 3500VA |
6,6kV | 1500VA | 750VA | 3500VA |
7,2kV | 1300VA | 600VA | 3200VA |
10kV | 1300VA | 600VA | 3200VA |
11kV | 1300VA | 600VA | 3200VA |
13,8kV | - | - | 3000VA |
17,5kV | - | - | 2000VA |
20kV | - | - | 2000VA |
22kV | - | - | 2000VA |
Dimensions
Wiring diagram: