Self estinguishing thermoplastic material |
UL94-V0 | |
---|---|---|
Operating frequency | 45 do 65 Hz | |
Insulation reference voltage | 0,72 kV | |
Test voltage | 3 kV 1min. 50 Hz | |
Insulation | E | |
Protection degree | IP 20 | |
Continuous overcurrent | 1,2 In | |
Rated short-time thermal current (l th) | 5 In(5sec.) | |
Alarms | 1 | |
Contact rating | 100mA, 250Vac | |
Alarm intervention indication | LED | |
Alarm type | MAX | |
Contact type | ||
- normally open | N.O. (cod. X...XMO) | |
- normally closed | N.C. (cod. X…XMC) | |
Alarm configuration | 10 do 120% In | |
Intevention delay | 0 do 6 s. | |
Hysteresis | 5% | |
Operating temperature | -10 +50 oC | |
Storage temperature | -30 +70oC | |
Manufactured according | IEC/EN 60044-1, VDE, BS, UTE | |
Integrated output terminals | 6 mm2 |
Type |
XAC032… |
XAC040… |
XAT061 |
XAT101 |
---|---|---|---|---|
Opening | ||||
Cable | Φ23 | Φ32 | Φ51 | |
Bar size | 32x10 mm | 40x 10 mm | 61 x 31 mm | 101x55 mm |
Pin description and diagram
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMC |
|||
100 A (10 to 120 A) |
XAC032100XMC |
|||
150 A (15 to 180A) |
XAC032150XMC |
|||
250 A (25 to 300 A) |
XAC032250XMC |
|||
400 A (40 to 480 A) |
XAC032400XMC |
XAC040400XMC |
||
600 A (60 to 720 A) |
XAC032600XMC |
XAC040600XMC |
XAT061600XMC |
|
1000 A (100 to 1200 A) |
XAC0401K0XMC |
XAT0611K0XMC |
XAT1011K0XMC |
|
1500 A (150 to 1800 A) |
XAT0611K5XMC |
XAT1011K5XMC |
||
2500 A (250 to 3000 A) |
XAT1012K5XMC |
: It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMO |
|||
100 A (10 to 120 A) |
XAC032100XMO |
|||
150 A (15 to 180A) |
XAC032150XMO |
|||
250 A (25 to 300 A) |
XAC032250XMO |
|||
400 A (40 to 480 A) |
XAC032400XMO |
XAC040400XMO |
||
600 A (60 to 720 A) |
XAC032600XMO |
XAC040600XMO |
XAT061600XMO |
|
1000 A (100 to 1200 A) |
XAC0401K0XMO |
XAT0611K0XMO |
XAT1011K0XMO |
|
1500 A (150 to 1800 A) |
XAT0611K5XMO |
XAT1011K5XMO |
||
2500 A (250 to 3000 A) |
XAT1012K5XMO |
It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
XAC032 |
XAC040 |
![]() |
![]() |
XAT061 |
XAT101 |
![]() |
![]() |
Signal alarm configuration
LED alarm signal
Normally open contact
Normally closed contact
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
Technical data
Self estinguishing thermoplastic material |
UL94-V0 | |
---|---|---|
Operating frequency | 45 do 65 Hz | |
Insulation reference voltage | 0,72 kV | |
Test voltage | 3 kV 1min. 50 Hz | |
Insulation | E | |
Protection degree | IP 20 | |
Continuous overcurrent | 1,2 In | |
Rated short-time thermal current (l th) | 5 In(5sec.) | |
Alarms | 1 | |
Contact rating | 100mA, 250Vac | |
Alarm intervention indication | LED | |
Alarm type | MAX | |
Contact type | ||
- normally open | N.O. (cod. X...XMO) | |
- normally closed | N.C. (cod. X…XMC) | |
Alarm configuration | 10 do 120% In | |
Intevention delay | 0 do 6 s. | |
Hysteresis | 5% | |
Operating temperature | -10 +50 oC | |
Storage temperature | -30 +70oC | |
Manufactured according | IEC/EN 60044-1, VDE, BS, UTE | |
Integrated output terminals | 6 mm2 |
Type |
XAC032… |
XAC040… |
XAT061 |
XAT101 |
---|---|---|---|---|
Opening | ||||
Cable | Φ23 | Φ32 | Φ51 | |
Bar size | 32x10 mm | 40x 10 mm | 61 x 31 mm | 101x55 mm |
Pin description and diagram
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMC |
|||
100 A (10 to 120 A) |
XAC032100XMC |
|||
150 A (15 to 180A) |
XAC032150XMC |
|||
250 A (25 to 300 A) |
XAC032250XMC |
|||
400 A (40 to 480 A) |
XAC032400XMC |
XAC040400XMC |
||
600 A (60 to 720 A) |
XAC032600XMC |
XAC040600XMC |
XAT061600XMC |
|
1000 A (100 to 1200 A) |
XAC0401K0XMC |
XAT0611K0XMC |
XAT1011K0XMC |
|
1500 A (150 to 1800 A) |
XAT0611K5XMC |
XAT1011K5XMC |
||
2500 A (250 to 3000 A) |
XAT1012K5XMC |
: It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
RANGE (alarm range) |
XAC032… |
XAC040… |
XAT061… |
XAT101… |
---|---|---|---|---|
Code | ||||
50 A (5 to 60A) |
XAC032050XMO |
|||
100 A (10 to 120 A) |
XAC032100XMO |
|||
150 A (15 to 180A) |
XAC032150XMO |
|||
250 A (25 to 300 A) |
XAC032250XMO |
|||
400 A (40 to 480 A) |
XAC032400XMO |
XAC040400XMO |
||
600 A (60 to 720 A) |
XAC032600XMO |
XAC040600XMO |
XAT061600XMO |
|
1000 A (100 to 1200 A) |
XAC0401K0XMO |
XAT0611K0XMO |
XAT1011K0XMO |
|
1500 A (150 to 1800 A) |
XAT0611K5XMO |
XAT1011K5XMO |
||
2500 A (250 to 3000 A) |
XAT1012K5XMO |
It is possible to set the Max. alarm threshold from10% to 120% of the current range (Example: Range=100A - Max. alarm threshold from 10A to 120A)
XAC032 |
XAC040 |
![]() |
![]() |
XAT061 |
XAT101 |
![]() |
![]() |
Signal alarm configuration
LED alarm signal
Normally open contact
Normally closed contact