GSA cast resin current transformers can be used for a variety of measuring, revenue metering (billing) and protection tasks. If the busbar systems or medium voltage cables are sufficiently insulated, these current transformers can be used for insulation levels higher than UM= 0,72kV (Highest voltage for equipment Um). The ring-type current transformer for outdoor use is also available on request (GSAF)
The current transformers are made of toroidal, soft magnetic, highly permeable tape-wound cores. The cores being uniformly wound with copper wire. For larger current strengths the cores come with stabilising windings to counteract the influence of external fields. Depending on the customer requirements each housing can accommodate up to five cores.
The output terminals are equiped with M5 screws. Protection against accidental contact is provided by a transparent polycarbonate cap. The modular mould system of the GSA permits almost any combination of housing and window sizes. To guarantee the mechanical and electrical resistance of the transformers they are encapsulated in a cast-resin housing with polyurethane. The GSA ring-type current transformers are equiped with two base plates as standard that allow them to be mounted in any position. They require no maintenance. In addition, for the outdoor transformers the output terminals are covered with an aluminium terminal box protected to IP54. Wire entry is via a PG16 threaded conduit in the terminal box.
When the current transformers need to be installed in locations with heavy vibration (for example, generator terminal boxes) the secondary terminals and the two base plates are reinforced in the resine housing (GSAG).
During the final inspection at ELEQ the current transformers are always subjected to a routine test in accordance with the relevant national and international standards.
Caution: if current transformers are operated open-circuited on the secondary side, extremely high voltages
can be generated with resultant damage to equipment and personnel!
General technical data:
Rated primary current | 20.….10000A |
---|---|
Rated secondary current | 1A, 5A |
Rated frequency | 50Hz, 60Hz |
Rated burden | according to customers requirement |
Accuracy class | according to customers requirement |
Rated insulation level | 0,72/3/-kV(1,2/6/-kV on request) |
Rated short-time thermal current | Minimum 100 x IN |
Standard | VDE, IEC, BC, ANSI itp. |
Dimensions GSA100, 110 and 120
|
Possible sizes
|
Dimensions remaining GSA’s |
Possible sizes | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?
Ajouter à la liste de souhaits
Vous devez être connecté
GSA cast resin current transformers can be used for a variety of measuring, revenue metering (billing) and protection tasks. If the busbar systems or medium voltage cables are sufficiently insulated, these current transformers can be used for insulation levels higher than UM= 0,72kV (Highest voltage for equipment Um). The ring-type current transformer for outdoor use is also available on request (GSAF)
The current transformers are made of toroidal, soft magnetic, highly permeable tape-wound cores. The cores being uniformly wound with copper wire. For larger current strengths the cores come with stabilising windings to counteract the influence of external fields. Depending on the customer requirements each housing can accommodate up to five cores.
The output terminals are equiped with M5 screws. Protection against accidental contact is provided by a transparent polycarbonate cap. The modular mould system of the GSA permits almost any combination of housing and window sizes. To guarantee the mechanical and electrical resistance of the transformers they are encapsulated in a cast-resin housing with polyurethane. The GSA ring-type current transformers are equiped with two base plates as standard that allow them to be mounted in any position. They require no maintenance. In addition, for the outdoor transformers the output terminals are covered with an aluminium terminal box protected to IP54. Wire entry is via a PG16 threaded conduit in the terminal box.
When the current transformers need to be installed in locations with heavy vibration (for example, generator terminal boxes) the secondary terminals and the two base plates are reinforced in the resine housing (GSAG).
During the final inspection at ELEQ the current transformers are always subjected to a routine test in accordance with the relevant national and international standards.
Caution: if current transformers are operated open-circuited on the secondary side, extremely high voltages
can be generated with resultant damage to equipment and personnel!
General technical data:
Rated primary current | 20.….10000A |
---|---|
Rated secondary current | 1A, 5A |
Rated frequency | 50Hz, 60Hz |
Rated burden | according to customers requirement |
Accuracy class | according to customers requirement |
Rated insulation level | 0,72/3/-kV(1,2/6/-kV on request) |
Rated short-time thermal current | Minimum 100 x IN |
Standard | VDE, IEC, BC, ANSI itp. |
Dimensions GSA100, 110 and 120
|
Possible sizes
|
Dimensions remaining GSA’s |
Possible sizes | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Votre avis ne peut pas être envoyé
Signaler le commentaire
Signalement envoyé
Votre signalement ne peut pas être envoyé
Donnez votre avis
Avis envoyé
Votre avis ne peut être envoyé