Les photos sont à titre informatif uniquement. Voir les spécifications du produit

please use latin characters

Transducteurs d'humidité et de température pour les applications de la série HVAC-L

Four designs duct version (LK)
  wall mounting (LW)
  rod-shaped Ø 12mm (LP)
  room version (LI)
Different humidity and temp., 2 x active  
  humidity active / temp. passive  
  humidity only, active  
  temperature only, active or passive  
Output signals 0…1 V  
  0…10 V  
  passive (temperature)  
Special versions sealing for increased requirements, e.g. condensation  
  sealing against vibrations  
Filter protective basket ZE07 (IP00)  
  filter with membrane ZE08 (IP30)  
  PTFE sintered filter ZE05 (IP65)  
Rod-shaped sensor with 2 types of connection 6-pin plug-in connection and assembled cable  
permanently attached cable  
 
Humidity    
•  sensing element calibrate sensor chip calHT 
•  output range 0…100%rh 
•  accuracy    
•  30…80%rh for 10…40°C  ±3 %rh  
•  remaining range  ±5 %rh   
•  influence of temperature. <10°C lub >40°C ±0,06%rh/K 
     
Temperature / active output    
•  sensing element calibrated sensor chip calHT 
•  output ranges 0…+50°C   
  -20…+80°C   
  -30…+70°C   
  0…+100°C   
•  Accuracy     
•  dla 10…40°C ±0,8K  
•  remaining range  chart   
•  The influence of temperature. <10°C lub >40°C ±0,06%rh/K 
     
Temperature / passive output    
•  sensign elements Pt100   
  Pt1000  
•[nbsp other sensing elements on demand e.g.. NTC
     
Electrical data    
•  outputs] 2 x 0…1V   
  2 x 0…10V   
  Wyjścia pasywne   
  na specjalne zamówienie   
•  Supply voltage    
•  LK, LW, LI  (6)13…30V DC lub  
•  output: 0…(1)10V  24V AC±10%  
•  LP     
•  outpug: 0…(1)10V  (6)12…30V DC   
•  load resistance for 0…1V  >1 kΩ 
output  0 .. .1V > 1kΩ  
output  0 ... 1V > 10 kΩ  
•  Kompatybilność  elektromagnetyczna  Zgodnie z EN 61326 
     
Generral data     
•  Medium air, pressureless, non-aggressive, non-condensing
   
   
•  Min. air speed 0,5m/s  
•  Temperatura pracy     
•  type LP, LK, LW   -30…+80°C   
•  type l LI  -20…+60°C   
•  storage temperature -40…+85°C
•  degree of protection of measuring head (series LK,LW,LI)
•  with protective basket ZE07 IP00   
•  with membrane filter ZE08 IP30   
•  with PTFE sintered filter ZE05 IP65   
•  degree of protection of housing
•  type LP, LK, LW  IP65   
•  typel LI IP30   
•  material of housing    
•  type LP, LK, LW   PC (light grey/ white)   
•  typel LI   ABS (white)  
Temperature accuracy

Przetworniki wilgotności i temperatury do zastosowań w HVAC - Seria L wykres dokładność temperatury

Working range of humidity and temperature

Przetworniki wilgotności i temperatury do zastosowań w HVAC - Seria L wykres zakres pracy

Envoyez une demande

Êtes-vous intéressé par ce produit? Avez-vous besoin d'informations supplémentaires ou d'une tarification individuelle?

Nous contacter
DEMANDEZ LE PRODUIT close
Merci d'avoir envoyé votre message. Nous vous répondrons dans les plus brefs délais.
DEMANDEZ LE PRODUIT close
Feuilleter

Ajouter à la liste de souhaits

Vous devez être connecté

Four designs duct version (LK)
  wall mounting (LW)
  rod-shaped Ø 12mm (LP)
  room version (LI)
Different humidity and temp., 2 x active  
  humidity active / temp. passive  
  humidity only, active  
  temperature only, active or passive  
Output signals 0…1 V  
  0…10 V  
  passive (temperature)  
Special versions sealing for increased requirements, e.g. condensation  
  sealing against vibrations  
Filter protective basket ZE07 (IP00)  
  filter with membrane ZE08 (IP30)  
  PTFE sintered filter ZE05 (IP65)  
Rod-shaped sensor with 2 types of connection 6-pin plug-in connection and assembled cable  
permanently attached cable  
 
Humidity    
•  sensing element calibrate sensor chip calHT 
•  output range 0…100%rh 
•  accuracy    
•  30…80%rh for 10…40°C  ±3 %rh  
•  remaining range  ±5 %rh   
•  influence of temperature. <10°C lub >40°C ±0,06%rh/K 
     
Temperature / active output    
•  sensing element calibrated sensor chip calHT 
•  output ranges 0…+50°C   
  -20…+80°C   
  -30…+70°C   
  0…+100°C   
•  Accuracy     
•  dla 10…40°C ±0,8K  
•  remaining range  chart   
•  The influence of temperature. <10°C lub >40°C ±0,06%rh/K 
     
Temperature / passive output    
•  sensign elements Pt100   
  Pt1000  
•[nbsp other sensing elements on demand e.g.. NTC
     
Electrical data    
•  outputs] 2 x 0…1V   
  2 x 0…10V   
  Wyjścia pasywne   
  na specjalne zamówienie   
•  Supply voltage    
•  LK, LW, LI  (6)13…30V DC lub  
•  output: 0…(1)10V  24V AC±10%  
•  LP     
•  outpug: 0…(1)10V  (6)12…30V DC   
•  load resistance for 0…1V  >1 kΩ 
output  0 .. .1V > 1kΩ  
output  0 ... 1V > 10 kΩ  
•  Kompatybilność  elektromagnetyczna  Zgodnie z EN 61326 
     
Generral data     
•  Medium air, pressureless, non-aggressive, non-condensing
   
   
•  Min. air speed 0,5m/s  
•  Temperatura pracy     
•  type LP, LK, LW   -30…+80°C   
•  type l LI  -20…+60°C   
•  storage temperature -40…+85°C
•  degree of protection of measuring head (series LK,LW,LI)
•  with protective basket ZE07 IP00   
•  with membrane filter ZE08 IP30   
•  with PTFE sintered filter ZE05 IP65   
•  degree of protection of housing
•  type LP, LK, LW  IP65   
•  typel LI IP30   
•  material of housing    
•  type LP, LK, LW   PC (light grey/ white)   
•  typel LI   ABS (white)  
Temperature accuracy

Przetworniki wilgotności i temperatury do zastosowań w HVAC - Seria L wykres dokładność temperatury

Working range of humidity and temperature

Przetworniki wilgotności i temperatury do zastosowań w HVAC - Seria L wykres zakres pracy

Commentaires (0)