LEM LA 100-P is a high-quality current transducer that provides precise measurement of DC, AC, pulsed, and mixed currents. It features high accuracy, excellent linearity, low temperature drift, and a wide bandwidth. With its fast response time and high resistance to electromagnetic interference, it is perfect for demanding industrial applications.
The device has galvanic isolation between the primary and secondary circuits, ensuring additional safety and insulation. LEM LA 100-P is used in variable speed AC drives, servo motor drives, DC motor converters, battery power supplies, UPS, SMPS, and welding systems.
Parameter | Value | ||||||
---|---|---|---|---|---|---|---|
Nominal Primary Current RMS | 100A | ||||||
Primary Current Measurement Range | 0…±150A | ||||||
Measuring Resistance at: | TA=70°C | TA=85°C | |||||
RM min | RM max | RM min | RM max | ||||
±12V | ±100Amax | 0 | 50Ω | 0 | 42Ω | ||
±120Amax | 0 | 22Ω | 0 | 14Ω | |||
±15V | ±100Amax | 0 | 110Ω | 20Ω | 102Ω | ||
±150Amax | 0 | 33Ω | 20Ω | 25Ω | |||
Nominal Secondary Current RMS | 50mA | ||||||
Ratio | 1:2000 | ||||||
Supply Voltage (±5%) | ±12…15V | ||||||
Current Consumption | 10 + ISmA | ||||||
Error at IPN, TA=25°C | ±15V (±5%) | ±0.45% | |||||
±12…15V (±5%) | ±0.70% | ||||||
Bandwidth (-1dB) | DC…200kHz | ||||||
Operating Temperature | -40÷85°C | ||||||
Storage Temperature | -40÷95°C | ||||||
Secondary Winding Resistance at: | TA=70°C | 120Ω | |||||
TA=85°C | 128Ω | ||||||
Weight | 18g |
Musisz być zalogowany/a
LEM LA 100-P is a high-quality current transducer that provides precise measurement of DC, AC, pulsed, and mixed currents. It features high accuracy, excellent linearity, low temperature drift, and a wide bandwidth. With its fast response time and high resistance to electromagnetic interference, it is perfect for demanding industrial applications.
The device has galvanic isolation between the primary and secondary circuits, ensuring additional safety and insulation. LEM LA 100-P is used in variable speed AC drives, servo motor drives, DC motor converters, battery power supplies, UPS, SMPS, and welding systems.
Parameter | Value | ||||||
---|---|---|---|---|---|---|---|
Nominal Primary Current RMS | 100A | ||||||
Primary Current Measurement Range | 0…±150A | ||||||
Measuring Resistance at: | TA=70°C | TA=85°C | |||||
RM min | RM max | RM min | RM max | ||||
±12V | ±100Amax | 0 | 50Ω | 0 | 42Ω | ||
±120Amax | 0 | 22Ω | 0 | 14Ω | |||
±15V | ±100Amax | 0 | 110Ω | 20Ω | 102Ω | ||
±150Amax | 0 | 33Ω | 20Ω | 25Ω | |||
Nominal Secondary Current RMS | 50mA | ||||||
Ratio | 1:2000 | ||||||
Supply Voltage (±5%) | ±12…15V | ||||||
Current Consumption | 10 + ISmA | ||||||
Error at IPN, TA=25°C | ±15V (±5%) | ±0.45% | |||||
±12…15V (±5%) | ±0.70% | ||||||
Bandwidth (-1dB) | DC…200kHz | ||||||
Operating Temperature | -40÷85°C | ||||||
Storage Temperature | -40÷95°C | ||||||
Secondary Winding Resistance at: | TA=70°C | 120Ω | |||||
TA=85°C | 128Ω | ||||||
Weight | 18g |