Parameter | Size |
Electrical Parameters | |
Supply Voltage | 90-250V AC 50/60Hz |
Maximum Power Consumption | 7VA |
Connections | Power terminal 2.5mm2, signal terminal 1.5mm2 |
Environmental Conditions | |
Operating/Storage Temperature | 0…+50°C/-25…70°C |
Degree of Protection | According to EN 60529; Front panel: IP65, Rear panel: IP20 |
Enclosure | |
Mounting Type | Mounting by compression on the panel |
Dimensions (width x height x depth) | 96x96x81mm |
Weight | Approx. 400g |
Enclosure Materials | Uses self-extinguishing plastics |
Note:
1) Power cables must meet the requirements of IEC 60277 or IEC 60245 standards.
2) According to safety regulations, the main switch must be in a location easily accessible to the operator and must have labeling indicating its importance to the device.
Translation | |
Original | Polish Translation |
To remove the device from the panel: - Stretch the compression fitting 1 in the direction of the arrow. - Pull the fitting in the direction of arrow 2. |
Aby odłączyć urządzenie od panelu: - Rozciągnąć złączkę zaciskową 1 w kierunku wskazanym strzałką. - Pociągnij złączkę w kierunku wskazanym strzałką 2. |
Panel Cut-Out | Wycięcie w panelu |
Compression Fitting | Mocowanie kompresyjne |
Note: 1- The panel thickness must be maximum 10mm. 2- If there is less than 60mm clearance behind the device, it becomes difficult to remove from the panel. |
Uwaga: 1- Grubość panelu musi wynosić maksymalnie 10 mm. 2- Jeśli za urządzeniem jest mniej niż 60 mm wolnej przestrzeni, usunięcie go z panelu będzie utrudnione. |
Button | Description |
![]() |
Changing parameter in “Menu Mode” |
![]() |
Return to the previous page in “Menu Mode” and exit from the current tab |
![]() |
Enter “Menu Mode” and navigate between options in “Menu Mode” |
![]() |
Increase the value of the selected parameter in “Menu Mode” |
![]() |
Decrease the value of the selected parameter in “Menu Mode” |
Tab | Description |
![]() |
Tab for entering IP addresses, subnet masks, gateways, etc. |
![]() |
Tab for setting BaudRate and other communication settings |
![]() |
Tab for pairing the ERC device with the server |
![]() |
Tab showing authorized email addresses |
![]() |
Tab showing monitored parameters |
![]() |
Tab for menu updates |
![]() |
Tab for resetting to factory settings |
·
Translation | |
Original | Polish Translation |
MODBUS CONNECTION DIAGRAM | Schemat połączenia Modbus |
Master Device | Urządzenie nadrzędne |
Slave Device | Urządzenie podrzędne |
Maximum 10 slave devices can be controlled | Maksymalnie 10 urządzeń podrzędnych może być kontrolowanych |
The communication line should be terminated with a 120 Ohm resistor at the beginning and end. | Linia komunikacyjna powinna posiadać terminator 120 Ohm na początku i końcu. |
Icon | Definition | Description | ||
![]() |
(1) Ethernet Status | Indicates whether the Ethernet cable is connected to the ERC device. | ||
(2) IP Status | Indicates whether the ERC device has obtained an IP address. | |||
(3) Internet Status | Indicates whether the ERC device has an internet connection. | |||
(4) Server Connection Status | Indicates the state of the connection between the ERC device and the server. | |||
![]() |
Slave Device Error Status | Indicates a connection error with the slave device connected to the ERC device. |
Also read:
Increase Efficiency and Safety: How the Industrial IoT Gateway ERC Modernizes Production Management
Revolution in Modern Automation: The Industrial IoT Gateway ERC from ENDA
Industrial IoT Gateway ERC in Food Production
Industrial IoT Gateway ENDA ERC in Pharmaceutical Manufacturing
Érdekel ez a termék? További információra vagy egyedi árajánlatra van szüksége?
Musisz być zalogowany/a
Parameter | Size |
Electrical Parameters | |
Supply Voltage | 90-250V AC 50/60Hz |
Maximum Power Consumption | 7VA |
Connections | Power terminal 2.5mm2, signal terminal 1.5mm2 |
Environmental Conditions | |
Operating/Storage Temperature | 0…+50°C/-25…70°C |
Degree of Protection | According to EN 60529; Front panel: IP65, Rear panel: IP20 |
Enclosure | |
Mounting Type | Mounting by compression on the panel |
Dimensions (width x height x depth) | 96x96x81mm |
Weight | Approx. 400g |
Enclosure Materials | Uses self-extinguishing plastics |
Note:
1) Power cables must meet the requirements of IEC 60277 or IEC 60245 standards.
2) According to safety regulations, the main switch must be in a location easily accessible to the operator and must have labeling indicating its importance to the device.
Translation | |
Original | Polish Translation |
To remove the device from the panel: - Stretch the compression fitting 1 in the direction of the arrow. - Pull the fitting in the direction of arrow 2. |
Aby odłączyć urządzenie od panelu: - Rozciągnąć złączkę zaciskową 1 w kierunku wskazanym strzałką. - Pociągnij złączkę w kierunku wskazanym strzałką 2. |
Panel Cut-Out | Wycięcie w panelu |
Compression Fitting | Mocowanie kompresyjne |
Note: 1- The panel thickness must be maximum 10mm. 2- If there is less than 60mm clearance behind the device, it becomes difficult to remove from the panel. |
Uwaga: 1- Grubość panelu musi wynosić maksymalnie 10 mm. 2- Jeśli za urządzeniem jest mniej niż 60 mm wolnej przestrzeni, usunięcie go z panelu będzie utrudnione. |
Button | Description |
![]() |
Changing parameter in “Menu Mode” |
![]() |
Return to the previous page in “Menu Mode” and exit from the current tab |
![]() |
Enter “Menu Mode” and navigate between options in “Menu Mode” |
![]() |
Increase the value of the selected parameter in “Menu Mode” |
![]() |
Decrease the value of the selected parameter in “Menu Mode” |
Tab | Description |
![]() |
Tab for entering IP addresses, subnet masks, gateways, etc. |
![]() |
Tab for setting BaudRate and other communication settings |
![]() |
Tab for pairing the ERC device with the server |
![]() |
Tab showing authorized email addresses |
![]() |
Tab showing monitored parameters |
![]() |
Tab for menu updates |
![]() |
Tab for resetting to factory settings |
·
Translation | |
Original | Polish Translation |
MODBUS CONNECTION DIAGRAM | Schemat połączenia Modbus |
Master Device | Urządzenie nadrzędne |
Slave Device | Urządzenie podrzędne |
Maximum 10 slave devices can be controlled | Maksymalnie 10 urządzeń podrzędnych może być kontrolowanych |
The communication line should be terminated with a 120 Ohm resistor at the beginning and end. | Linia komunikacyjna powinna posiadać terminator 120 Ohm na początku i końcu. |
Icon | Definition | Description | ||
![]() |
(1) Ethernet Status | Indicates whether the Ethernet cable is connected to the ERC device. | ||
(2) IP Status | Indicates whether the ERC device has obtained an IP address. | |||
(3) Internet Status | Indicates whether the ERC device has an internet connection. | |||
(4) Server Connection Status | Indicates the state of the connection between the ERC device and the server. | |||
![]() |
Slave Device Error Status | Indicates a connection error with the slave device connected to the ERC device. |
Also read:
Increase Efficiency and Safety: How the Industrial IoT Gateway ERC Modernizes Production Management
Revolution in Modern Automation: The Industrial IoT Gateway ERC from ENDA
Industrial IoT Gateway ERC in Food Production
Industrial IoT Gateway ENDA ERC in Pharmaceutical Manufacturing
A megfogalmazott véleményedet nem lehet elküldeni
Hozzászólás jelentése
Jelentés elküldve
Jelentésed beküldése nem lehetséges
Írd meg véleményedet
Vélemény elküldve
Véleményed nem lehet elküldeni