Application
This series of devices was specially developed for use in heating technology; in boiler systems or storage tanks; district heating transfer stations and heat transfer systems; in ventilation technology to monitor supply air or as limiters for electrical heating coils, as well as for controlling and monitoring temperatures in pipelines and tanks. Immersion sleeves, protection coils and mounting sets are not included in the scope of delivery. The JZ-29 mounting set must be used in conjunction with immersion sleeves or protection coils. When used as contact controller (pipe mounting), mounting set JZ-31 must be used.
Technical data
Colour: | Anthracite grey (similar to RAL 7016), front side transparent |
Sensor material: | Cu |
Sensor length: | 2 m |
Max. sensor temperature | Top scale value +15% |
Max. head temperature: | 80 °C |
Permissible atmospheric humidity: | Max. 95% rel. humidity, non-condensing |
Operating voltage: | none |
Max. switching current: | NC contact: 16 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TR/TW/STW: 6.3 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TB: 2.0 (0.4) A at 230 VAC +10% 0.25 A at 230 VDC +10% |
Min. switching current: | Min. 100 mA at 24 V (AC/DC) |
Max. switching voltage: | 230 VAC 50/60 Hz, 230 VDC |
Min. switching voltage: | 24 VAC/50 Hz, 24 VDC |
Switching element: | microswitch |
Switching contact: | toggler, potential-free |
Control range: | heating or cooling |
Electrical connection: | Push-in terminals |
Mounting/attachment: | Wall mounting or with optional process connection (immersion sleeve, protection coil or mounting set JZ-31 for pipe mounting) |
Protection class: | I |
Protection rating: | RTKSA-xxx.x0x IP 40, RTKSA-xxx.x1x IP 54, optional IP 65 |
Safety and EMC: | In accordance with DIN EN 60730 (VDE 0631) |
Sensor: | liquid-filled capillary |
General features: | Scale: degrees Celsius |
Type | Item no. | Control range | Hysteresis | Sensor Ø x L | Features | PG |
---|---|---|---|---|---|---|
RTKSA-000.100 | KA000000 | 0…50 °C | 1.3 K | 6 x 175 mm | TR, external setting | II |
RTKSA-000.200 | KA000001 | 0…120 °C | 3 K | 6 x 87 mm | TR, external setting | II |
RTKSA-000.300 | KA000002 | 20…150 °C | 9.1 K | 6 x 56 mm | TR, external setting | II |
RTKSA-001.100 | KA000100 | 0…50 °C | 1.3 K | 6 x 175 mm | TW, internal setting | II |
RTKSA-001.200 | KA000101 | 0…120 °C | 3 K | 6 x 87 mm | TW, internal setting | II |
RTKSA-001.300 | KA000102 | 20…150 °C | 9.1 K | 6 x 56 mm | TW, internal setting | II |
RTKSA-001.301 | KA000103 | 20…150 °C | 3.3 K | 6 x 82 mm | TW, internal setting | II |
RTKSA-002.310 | KA000201 | 20…150 °C | -10… -15 K* | 6 x 55 mm | TB, internal setting, external reset | II |
RTKSA-002.410 | KA000200 | 30…110 °C | -10…-15 K* | 6 x 72 mm | TB, internal setting, external reset | II |
RTKSA-003.310 | KA000300 | 20…150 °C | -10…-15 K* | 6 x 55 mm | STB, internal setting, external reset | II |
RTKSA-004.310 | KA000400 | 20…150 °C | −10 K | 6 x 55 mm | STW, internal setting | II |
TR = temperature controller, TW = temperature monitor, TB = temperature limiter, STB = safety temperature limiter, STW = safety temperature monitor
* Manual reset after cooling down by 10–15 K (depending on configured setpoint)
Universal capillary thermostat RTKSA
Accessories | Item no. | Length of | Material | Diameter IxA** | Features | PG |
---|---|---|---|---|---|---|
THK-2-100 | KA969901 | 100 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-120 | KA969902 | 120 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-200 | KA969903 | 200 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-280 | KA969904 | 280 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-600 | KA969905 | 600 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-100 | KA969906 | 100 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-120 | KA969907 | 120 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-200 | KA969908 | 200 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-280 | KA969909 | 280 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
SWK-2-100 | KA989901 | 100 mm | steel, nickel-plated | 10.5 x 17 mm | Protection coil with flange plate | II |
SWK-2-120 | KA989902 | 120 mm | steel, nickel-plated | 10,5 x 17 mm | Protection coil with flange plate | II |
SWK-2-200 | KA989903 | 200 mm | steel, nickel-plated | 10.5 x 17 mm | Protection coil with flange plate | II |
** I = minimum inner diameter / A = nominal outer diameter
See page 218–219 for pictures and dimension diagrams for immersion sleeves/protection coils
Accessories | Item no. | Features | PG |
---|---|---|---|
JZ-29 | KA999901 | Mounting set RTKSA for THK/NTHK/SWK individual controllers | II |
JZ-31 | KA999903 | Mounting set RTKSA for pipe mounting contact controller (worm screw clamp) | II |
Type comparison (old/new type)
Old alre types | Control range | Hysteresis | New alre types | Control range | Hysteresis | Accessories |
---|---|---|---|---|---|---|
KR 80.312 | fixed at 100 °C | −20 K | RTKSA-003.310 | 20…150 °C | −10 K | THK-2-100 + JZ-29 |
LR 80.312 | fixed at 100 °C | −20 K | SWK-2-100 + JZ-29 | |||
KR 80.318 | fixed at 100 °C | −20 K | THK-2-200 + JZ-29 | |||
LR 80.318 | fixed at 100 °C | −20 K | SWK-2-200 + JZ-29 | |||
KR 80.309 | fixed at 75 °C | −20 K | THK-2-100 + JZ-29 | |||
LR 80.309 | fixed at 75 °C | −20 K | SWK-2-100 + JZ-29 | |||
KR 80.310 | fixed at 75 °C | −20 K | THK-2-200 + JZ-29 | |||
LR 80.310 | fixed at 75 °C | −20 K | SWK-2-200 + JZ-29 | |||
KR 80.206 | 30…65 °C | −8 K | RTKSA-002.410 | 30…110 °C | −10 K | THK-2-100 + JZ-29 |
KR 80.206 IP 54 | 30…65 °C | −8 K | THK-2-100 + JZ-29 | |||
KR 80.207 | 60…95 °C | −8 K | THK-2-100 + JZ-29 | |||
LR 80.207 | 60…95 °C | −8 K | SWK-2-100 + JZ-29 | |||
KR 80.208 | 85…120 °C | −8 K | RTKSA-002.310 | 20…150 °C | −10 K | THK-2-100 + JZ-29 |
KR 80.202 | 95…130 °C | −8 K | THK-2-100 + JZ-29 | |||
KR 80.203 | 95…130 °C | −8 K | THK-2-200 + JZ-29 | |||
LR 80.203 | 95…130 °C | −8 K | SWK-2-200 + JZ-29 | |||
KR 80.203 IP 54 | 95…130 °C | −8 K | THK-2-200 + JZ-29 | |||
WR 81.029-1 | 0…35 °C | 0.5…1 K | RTKSA-000.100 | 0…50 °C | 1.3 K | - |
KR 80.003-1 | 0…35 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.003-1 | 0…35 °C | 1 K | SWK-2-200 | |||
WR 81.009-2 | 0…70 °C | 1 … 2 K | RTKSA-000.200 | 0…120 °C | 3 K | - |
KR 80.035-2 | 0…70 °C | 2 K | THK-2-100 + JZ-29 | |||
KR 80.027-5 | 0…70 °C | 5 K | THK-2-100 + JZ-29 | |||
LR 80.027-5 | 0…70 °C | 5 K | SWK-2-100 + JZ-29 | |||
LR 80.035-2 | 0…70 °C | 2 K | SWK-2-100 + JZ-29 | |||
KR 80.028-2 | 0…70 °C | 2 K | THK-2-200 + JZ-29 | |||
LR 80.028-2 | 0…70 °C | 2 K | SWK-2-200 + JZ-29 | |||
KR 80.029-2 | 0…70 °C | 2 K | THK-2-280 + JZ-29 | |||
KR 80.029-2 V4A | 0…70 °C | 3 K | NTHK-2-280 + JZ-29 | |||
LR 80.029-2 | 0…70 °C | 2 K | SWK-2-280 + JZ-29 | |||
KR 80.011-1 V4A | 10…45 °C | 1 K | NTHK-2-120 + JZ-29 | |||
KR 80.009-1 V4A | 10…45 °C | 1 K | NTHK-2-200 + JZ-29 | |||
KR 80.000-5 | 35…95 °C | 5 K | THK-2-100 + JZ-29 | |||
KR 80.001-5 | 35…95 °C | 5 K | THK-2-200 + JZ-29 | |||
KR 80.001-5 V4A | 35…95 °C | 5 K | NTHK-2-200 + JZ-29 | |||
KR 80.008-8 | 40…110 °C | 8 K | THK-2-100 + JZ-29 | |||
KR 80.006-8 | 50…130 °C | 8 K | RTKSA-000.300 | 20…150 °C | 9.1 K | THK-2-100 + JZ-29 |
WR 81.101-1 | 0…35 °C | 0.5…1 K | RTKSA-001.100 | 0…50 °C | 1.3 K | - |
WR 81.129-1 | 0…35 °C | 0.5…1 K | - | |||
KR 80.108-1 | 0…35 °C | 1 K | - | |||
LR 80.108-1 | 0…35 °C | 1 K | - | |||
KR 80.109-1 | 0…35 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.109-1 | 0…35 °C | 1 K | SWK-2-200 + JZ-29 | |||
WR 81.115-5 | 0…70 °C | 4 K | RTKSA-001.200 | 0…120 °C | 3 K | JZ-31 |
WR 81.109-2 | 0…70 °C | 1…2 K | - | |||
KR 80.116-2 | 0…70 °C | 2 K | THK-2-100 + JZ-29 | |||
LR 80.116-2 | 0…70 °C | 2 K | SWK-2-100 + JZ-29 | |||
KR 80.111-3 | 0…80 °C | 1 K | THK-2-100 + JZ-29 | |||
KR 80.120-1 | 10…45 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.120-1 | 10…45 °C | 1 K | SWK-2-200 + JZ-29 | |||
KR 80.100-5 | 35…95 °C | 5 K | RTKSA-001.301 | 20…150 °C | 3.3 K | THK-2-100 + JZ-29 |
KR 80.100-5 IP 54 | 35…95 °C | 5 K | NTHK-2-100 + JZ-29 | |||
KR 80.101-5 | 35…95 °C | 5 K | THK-2-200 + JZ-29 | |||
LR 80.101-5 | 35…95 °C | 5 K | SWK-2-200 + JZ-29 | |||
KR 80.124-5 | 35…95 °C | 5 K | THK-2-280 + JZ-29 | |||
KR 80.112-5 | 35…95 °C | 8 K | RTKSA-001.300 | 20…150 °C | 9.1 K | THK-2-600 + JZ-29 |
KR 80.102-8 | 40…110 °C | 8 K | THK-2-100 + JZ-29 | |||
KR 80.103-8 | 40…110 °C | 8 K | THK-2-200 + JZ-29 | |||
WR 81.117-5 | 50…130 °C | 4 K | JZ-31 | |||
KR 80.106-8 | 50…130 °C | 8 K | THK-2-100 + JZ-29 |
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
Application
This series of devices was specially developed for use in heating technology; in boiler systems or storage tanks; district heating transfer stations and heat transfer systems; in ventilation technology to monitor supply air or as limiters for electrical heating coils, as well as for controlling and monitoring temperatures in pipelines and tanks. Immersion sleeves, protection coils and mounting sets are not included in the scope of delivery. The JZ-29 mounting set must be used in conjunction with immersion sleeves or protection coils. When used as contact controller (pipe mounting), mounting set JZ-31 must be used.
Technical data
Colour: | Anthracite grey (similar to RAL 7016), front side transparent |
Sensor material: | Cu |
Sensor length: | 2 m |
Max. sensor temperature | Top scale value +15% |
Max. head temperature: | 80 °C |
Permissible atmospheric humidity: | Max. 95% rel. humidity, non-condensing |
Operating voltage: | none |
Max. switching current: | NC contact: 16 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TR/TW/STW: 6.3 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TB: 2.0 (0.4) A at 230 VAC +10% 0.25 A at 230 VDC +10% |
Min. switching current: | Min. 100 mA at 24 V (AC/DC) |
Max. switching voltage: | 230 VAC 50/60 Hz, 230 VDC |
Min. switching voltage: | 24 VAC/50 Hz, 24 VDC |
Switching element: | microswitch |
Switching contact: | toggler, potential-free |
Control range: | heating or cooling |
Electrical connection: | Push-in terminals |
Mounting/attachment: | Wall mounting or with optional process connection (immersion sleeve, protection coil or mounting set JZ-31 for pipe mounting) |
Protection class: | I |
Protection rating: | RTKSA-xxx.x0x IP 40, RTKSA-xxx.x1x IP 54, optional IP 65 |
Safety and EMC: | In accordance with DIN EN 60730 (VDE 0631) |
Sensor: | liquid-filled capillary |
General features: | Scale: degrees Celsius |
Type | Item no. | Control range | Hysteresis | Sensor Ø x L | Features | PG |
---|---|---|---|---|---|---|
RTKSA-000.100 | KA000000 | 0…50 °C | 1.3 K | 6 x 175 mm | TR, external setting | II |
RTKSA-000.200 | KA000001 | 0…120 °C | 3 K | 6 x 87 mm | TR, external setting | II |
RTKSA-000.300 | KA000002 | 20…150 °C | 9.1 K | 6 x 56 mm | TR, external setting | II |
RTKSA-001.100 | KA000100 | 0…50 °C | 1.3 K | 6 x 175 mm | TW, internal setting | II |
RTKSA-001.200 | KA000101 | 0…120 °C | 3 K | 6 x 87 mm | TW, internal setting | II |
RTKSA-001.300 | KA000102 | 20…150 °C | 9.1 K | 6 x 56 mm | TW, internal setting | II |
RTKSA-001.301 | KA000103 | 20…150 °C | 3.3 K | 6 x 82 mm | TW, internal setting | II |
RTKSA-002.310 | KA000201 | 20…150 °C | -10… -15 K* | 6 x 55 mm | TB, internal setting, external reset | II |
RTKSA-002.410 | KA000200 | 30…110 °C | -10…-15 K* | 6 x 72 mm | TB, internal setting, external reset | II |
RTKSA-003.310 | KA000300 | 20…150 °C | -10…-15 K* | 6 x 55 mm | STB, internal setting, external reset | II |
RTKSA-004.310 | KA000400 | 20…150 °C | −10 K | 6 x 55 mm | STW, internal setting | II |
TR = temperature controller, TW = temperature monitor, TB = temperature limiter, STB = safety temperature limiter, STW = safety temperature monitor
* Manual reset after cooling down by 10–15 K (depending on configured setpoint)
Universal capillary thermostat RTKSA
Accessories | Item no. | Length of | Material | Diameter IxA** | Features | PG |
---|---|---|---|---|---|---|
THK-2-100 | KA969901 | 100 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-120 | KA969902 | 120 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-200 | KA969903 | 200 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-280 | KA969904 | 280 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
THK-2-600 | KA969905 | 600 mm | nickel-plated brass | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-100 | KA969906 | 100 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-120 | KA969907 | 120 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-200 | KA969908 | 200 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
NTHK-2-280 | KA969909 | 280 mm | V4A (1.4571) | 7.5 x 10 mm | Immersion sleeve | II |
SWK-2-100 | KA989901 | 100 mm | steel, nickel-plated | 10.5 x 17 mm | Protection coil with flange plate | II |
SWK-2-120 | KA989902 | 120 mm | steel, nickel-plated | 10,5 x 17 mm | Protection coil with flange plate | II |
SWK-2-200 | KA989903 | 200 mm | steel, nickel-plated | 10.5 x 17 mm | Protection coil with flange plate | II |
** I = minimum inner diameter / A = nominal outer diameter
See page 218–219 for pictures and dimension diagrams for immersion sleeves/protection coils
Accessories | Item no. | Features | PG |
---|---|---|---|
JZ-29 | KA999901 | Mounting set RTKSA for THK/NTHK/SWK individual controllers | II |
JZ-31 | KA999903 | Mounting set RTKSA for pipe mounting contact controller (worm screw clamp) | II |
Type comparison (old/new type)
Old alre types | Control range | Hysteresis | New alre types | Control range | Hysteresis | Accessories |
---|---|---|---|---|---|---|
KR 80.312 | fixed at 100 °C | −20 K | RTKSA-003.310 | 20…150 °C | −10 K | THK-2-100 + JZ-29 |
LR 80.312 | fixed at 100 °C | −20 K | SWK-2-100 + JZ-29 | |||
KR 80.318 | fixed at 100 °C | −20 K | THK-2-200 + JZ-29 | |||
LR 80.318 | fixed at 100 °C | −20 K | SWK-2-200 + JZ-29 | |||
KR 80.309 | fixed at 75 °C | −20 K | THK-2-100 + JZ-29 | |||
LR 80.309 | fixed at 75 °C | −20 K | SWK-2-100 + JZ-29 | |||
KR 80.310 | fixed at 75 °C | −20 K | THK-2-200 + JZ-29 | |||
LR 80.310 | fixed at 75 °C | −20 K | SWK-2-200 + JZ-29 | |||
KR 80.206 | 30…65 °C | −8 K | RTKSA-002.410 | 30…110 °C | −10 K | THK-2-100 + JZ-29 |
KR 80.206 IP 54 | 30…65 °C | −8 K | THK-2-100 + JZ-29 | |||
KR 80.207 | 60…95 °C | −8 K | THK-2-100 + JZ-29 | |||
LR 80.207 | 60…95 °C | −8 K | SWK-2-100 + JZ-29 | |||
KR 80.208 | 85…120 °C | −8 K | RTKSA-002.310 | 20…150 °C | −10 K | THK-2-100 + JZ-29 |
KR 80.202 | 95…130 °C | −8 K | THK-2-100 + JZ-29 | |||
KR 80.203 | 95…130 °C | −8 K | THK-2-200 + JZ-29 | |||
LR 80.203 | 95…130 °C | −8 K | SWK-2-200 + JZ-29 | |||
KR 80.203 IP 54 | 95…130 °C | −8 K | THK-2-200 + JZ-29 | |||
WR 81.029-1 | 0…35 °C | 0.5…1 K | RTKSA-000.100 | 0…50 °C | 1.3 K | - |
KR 80.003-1 | 0…35 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.003-1 | 0…35 °C | 1 K | SWK-2-200 | |||
WR 81.009-2 | 0…70 °C | 1 … 2 K | RTKSA-000.200 | 0…120 °C | 3 K | - |
KR 80.035-2 | 0…70 °C | 2 K | THK-2-100 + JZ-29 | |||
KR 80.027-5 | 0…70 °C | 5 K | THK-2-100 + JZ-29 | |||
LR 80.027-5 | 0…70 °C | 5 K | SWK-2-100 + JZ-29 | |||
LR 80.035-2 | 0…70 °C | 2 K | SWK-2-100 + JZ-29 | |||
KR 80.028-2 | 0…70 °C | 2 K | THK-2-200 + JZ-29 | |||
LR 80.028-2 | 0…70 °C | 2 K | SWK-2-200 + JZ-29 | |||
KR 80.029-2 | 0…70 °C | 2 K | THK-2-280 + JZ-29 | |||
KR 80.029-2 V4A | 0…70 °C | 3 K | NTHK-2-280 + JZ-29 | |||
LR 80.029-2 | 0…70 °C | 2 K | SWK-2-280 + JZ-29 | |||
KR 80.011-1 V4A | 10…45 °C | 1 K | NTHK-2-120 + JZ-29 | |||
KR 80.009-1 V4A | 10…45 °C | 1 K | NTHK-2-200 + JZ-29 | |||
KR 80.000-5 | 35…95 °C | 5 K | THK-2-100 + JZ-29 | |||
KR 80.001-5 | 35…95 °C | 5 K | THK-2-200 + JZ-29 | |||
KR 80.001-5 V4A | 35…95 °C | 5 K | NTHK-2-200 + JZ-29 | |||
KR 80.008-8 | 40…110 °C | 8 K | THK-2-100 + JZ-29 | |||
KR 80.006-8 | 50…130 °C | 8 K | RTKSA-000.300 | 20…150 °C | 9.1 K | THK-2-100 + JZ-29 |
WR 81.101-1 | 0…35 °C | 0.5…1 K | RTKSA-001.100 | 0…50 °C | 1.3 K | - |
WR 81.129-1 | 0…35 °C | 0.5…1 K | - | |||
KR 80.108-1 | 0…35 °C | 1 K | - | |||
LR 80.108-1 | 0…35 °C | 1 K | - | |||
KR 80.109-1 | 0…35 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.109-1 | 0…35 °C | 1 K | SWK-2-200 + JZ-29 | |||
WR 81.115-5 | 0…70 °C | 4 K | RTKSA-001.200 | 0…120 °C | 3 K | JZ-31 |
WR 81.109-2 | 0…70 °C | 1…2 K | - | |||
KR 80.116-2 | 0…70 °C | 2 K | THK-2-100 + JZ-29 | |||
LR 80.116-2 | 0…70 °C | 2 K | SWK-2-100 + JZ-29 | |||
KR 80.111-3 | 0…80 °C | 1 K | THK-2-100 + JZ-29 | |||
KR 80.120-1 | 10…45 °C | 1 K | THK-2-200 + JZ-29 | |||
LR 80.120-1 | 10…45 °C | 1 K | SWK-2-200 + JZ-29 | |||
KR 80.100-5 | 35…95 °C | 5 K | RTKSA-001.301 | 20…150 °C | 3.3 K | THK-2-100 + JZ-29 |
KR 80.100-5 IP 54 | 35…95 °C | 5 K | NTHK-2-100 + JZ-29 | |||
KR 80.101-5 | 35…95 °C | 5 K | THK-2-200 + JZ-29 | |||
LR 80.101-5 | 35…95 °C | 5 K | SWK-2-200 + JZ-29 | |||
KR 80.124-5 | 35…95 °C | 5 K | THK-2-280 + JZ-29 | |||
KR 80.112-5 | 35…95 °C | 8 K | RTKSA-001.300 | 20…150 °C | 9.1 K | THK-2-600 + JZ-29 |
KR 80.102-8 | 40…110 °C | 8 K | THK-2-100 + JZ-29 | |||
KR 80.103-8 | 40…110 °C | 8 K | THK-2-200 + JZ-29 | |||
WR 81.117-5 | 50…130 °C | 4 K | JZ-31 | |||
KR 80.106-8 | 50…130 °C | 8 K | THK-2-100 + JZ-29 |