Ventiliatorius su filtru FF 018 serijos: 550 m³/h
  • Ventiliatorius su filtru FF 018 serijos: 550 m³/h

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: STEGO

Ventiliatorius su filtru FF 018 serijos: 550 m³/h

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from over - heating. The high-performance axial fan provides high air circulation. These filter fans are intended for indoor use. The plastic used for the hood is highly UV light resistant.

Technical data
Axial fan, ball bearing service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor metal.
Connection 3-pole clamp for 2.5mm², clamping torque 0.8Nm max.
Casing (filter fan and exit filter) plastic according to UL94 V-0, light grey
Mounting  frame

with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional  use of screws necessary (see drilling template);
a template for the enclosure cut-out  is included in the delivery of the filter fans

Filter  mat

G4 acc. to DIN EN 779, filtering  degree 94%

Filter material synthetic fibre with progressive construction,
temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH,
reusable - cleaning by washing or vacuuming
Operating/Storage temperature - 25°C - +70°C
Protection class I (eathed)

Wkłady zapasowe FM 086/FFM 086
Filter mat 247x247 mm
G4 (1 packing = 3 pcs) Art. No. 08608.0-00
F5 (1 packing = 3 pcsi) Nr art. 08609.0-00


|Dimensions [mm]
 
Filter fan FF 018
Art. No. Operating
voltage
Air volume, free flow Air volume with exit filter Curent
consuption
Power Average noise level (DIN EN ISO 4871) Depth in ecclosure Enclosure
cut-out
Weight
(approx.)
Protection
type

01805.0-00

AC 230 V, 50 Hz 550 m³/h 300 m³/h 300 mA 64W 65dB(A) 107 mm 250 x 250 mm + 0,4 2,70 kg IP54

01805.0-01

AC120V, 60 Hz* 550 m³/h 300 m³/h 780 mA 85 W 65 dB (A) 107 mm 250 x 250 mm + 0,4 2,70 kg IP54


Exit filter EF 118
Art. No. Depth in enclosure Enclosure
cut-out
Weight
(approx.)
Filter mat Protection
type

11803.0-00

22 mm 250 x 250 mm + 0,4 1,00 kg G4 acc. to DIN EN 779, filtering  degree 94% IP54*


Filter fan with air flow sensing device 218 FELT
Art. No. Operating
voltage
Air volume, free flow Air volume with exit filter Curent
consuption
Power Average noise level (DIN EN ISO 4871) Depth in ecclosure Enclosure
cut-out
Weight
(approx.)

21805.0-00

AC230V, 50 Hz 550 m³/h 300 m³/h 300 mA 64 W 65 dB (A) 107 mm 250 x250 mm + 0,4 2,70 kg

21805.0-01

AC 120V, 60Hz* 550 m³/h 300 m³/h 780 mA 85 W 65 dB (A) 107 mm 250 x250 mm + 0,4 2,70 kg

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from over - heating. The high-performance axial fan provides high air circulation. These filter fans are intended for indoor use. The plastic used for the hood is highly UV light resistant.

Technical data
Axial fan, ball bearing service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor metal.
Connection 3-pole clamp for 2.5mm², clamping torque 0.8Nm max.
Casing (filter fan and exit filter) plastic according to UL94 V-0, light grey
Mounting  frame

with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional  use of screws necessary (see drilling template);
a template for the enclosure cut-out  is included in the delivery of the filter fans

Filter  mat

G4 acc. to DIN EN 779, filtering  degree 94%

Filter material synthetic fibre with progressive construction,
temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH,
reusable - cleaning by washing or vacuuming
Operating/Storage temperature - 25°C - +70°C
Protection class I (eathed)

Wkłady zapasowe FM 086/FFM 086
Filter mat 247x247 mm
G4 (1 packing = 3 pcs) Art. No. 08608.0-00
F5 (1 packing = 3 pcsi) Nr art. 08609.0-00


|Dimensions [mm]
 
Filter fan FF 018
Art. No. Operating
voltage
Air volume, free flow Air volume with exit filter Curent
consuption
Power Average noise level (DIN EN ISO 4871) Depth in ecclosure Enclosure
cut-out
Weight
(approx.)
Protection
type

01805.0-00

AC 230 V, 50 Hz 550 m³/h 300 m³/h 300 mA 64W 65dB(A) 107 mm 250 x 250 mm + 0,4 2,70 kg IP54

01805.0-01

AC120V, 60 Hz* 550 m³/h 300 m³/h 780 mA 85 W 65 dB (A) 107 mm 250 x 250 mm + 0,4 2,70 kg IP54


Exit filter EF 118
Art. No. Depth in enclosure Enclosure
cut-out
Weight
(approx.)
Filter mat Protection
type

11803.0-00

22 mm 250 x 250 mm + 0,4 1,00 kg G4 acc. to DIN EN 779, filtering  degree 94% IP54*


Filter fan with air flow sensing device 218 FELT
Art. No. Operating
voltage
Air volume, free flow Air volume with exit filter Curent
consuption
Power Average noise level (DIN EN ISO 4871) Depth in ecclosure Enclosure
cut-out
Weight
(approx.)

21805.0-00

AC230V, 50 Hz 550 m³/h 300 m³/h 300 mA 64 W 65 dB (A) 107 mm 250 x250 mm + 0,4 2,70 kg

21805.0-01

AC 120V, 60Hz* 550 m³/h 300 m³/h 780 mA 85 W 65 dB (A) 107 mm 250 x250 mm + 0,4 2,70 kg