Stogo ventiliatorius su filtru REP 018 serijos: 300 m³/h, 500 m³/h
  • Stogo ventiliatorius su filtru REP 018 serijos: 300 m³/h, 500 m³/h

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: STEGO

Stogo ventiliatorius su filtru REP 018 serijos: 300 m³/h, 500 m³/h

  • Verylownoise
  • Minimaldepthinenclosure
  • Highthrough-flowairvolume
  • Highreliability
  • Time-savinginstallationandmatexchange
Roof filter fans find use in enclosures and housings, from which warm air has to be diverted to lower the internal temperature. These low-noise roof filter fans are used to expel warm air from within the enclosure which has been generated by the stray power of the components and so protects the internal devices from overheating. To exchange the filter mat the hood can be easily opened without tools. The roof exit filter provides passive ventilation
 
Technical Data:
Axial fans, ball bearing
service life 50,000h at 25°C/77°F (65% RH) fan body aluminium, rotor plastic
Connection
3-pole clamp for 2.5mm², clamping torque 0.8Nm max.
Case
plastic according to UL94 V-0, light grey; weather proof and UV light resistant according UL746C (f1)
Filter mat
G3 acc. to DIN EN 779, filtering degree 85%
Filter material
synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1;
moisture resistant to 100% RH, reusable - cleaning by
Operating / Storage temperature
- 45 oC do + 70 oC
Prot. type
IP43 (with the contribution of G3) / IP33 (without filter G3)
Protection class
I(earthed)
Approvals
UL intended; (230V only: VDE)

Important note
For reasons of pressure compensation the roof filter fan must always be operated in
combination with a passive intake filter (e.g. Art. No. 11803.0-00) or another filter fan (e.g. Art. No. 01803.0-00).

Roof Filter Fan RFP 018 Series

Art. No. Operating voltage Air volume,
free flow
Air volume,
free flow
Current
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Enclosure
cut-out
Weight
(approx.)
01860.0-00 AC 230V, 50Hz 300m3/h
(with the contribution of G3)
400m3/h
(without filter G3)
68W 55dB (A) 52mm 250 x 250mm + 0.4 3.3kg
01861.0-00 AC 230V, 50Hz 500m3/h
(with the contribution of G3)
650m3/h
(without filter G3)
64W 67dB (A) 107mm 250 x 250mm + 0.4 2.6kg
01860.0-02 AC 120V, 60Hz 345m3/h
(with the contribution of G3)
460m3/h
(without filter G3)
60W 55dB (A) 52mm 250 x 250mm + 0.4 3.3kg
01861.0-02 AC 120V, 60Hz 575m3/h
(with the contribution of G3)
748m3/h
(without filter G3)
85W 67dB (A) 107mm 250 x 250mm
+ 0,4
2.6kg


Roof Exit Filter REP 118 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
11860.0-00 11mm 250 x 250mm + 0.4 1.Okg G3 acc. to DIN EN 779, filtering degree 85% IP43 (z f. G3)/ IP 33 (bez f. G3)


Filter Mat FM 086
Filter mat 282 x 282mm
G3 (1 packing unit = 3 pcs.) Art. No. 08613.0-00


Roof fan (01860.0-xx)
Roof fan (01861.00-xx)

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

  • Verylownoise
  • Minimaldepthinenclosure
  • Highthrough-flowairvolume
  • Highreliability
  • Time-savinginstallationandmatexchange
Roof filter fans find use in enclosures and housings, from which warm air has to be diverted to lower the internal temperature. These low-noise roof filter fans are used to expel warm air from within the enclosure which has been generated by the stray power of the components and so protects the internal devices from overheating. To exchange the filter mat the hood can be easily opened without tools. The roof exit filter provides passive ventilation
 
Technical Data:
Axial fans, ball bearing
service life 50,000h at 25°C/77°F (65% RH) fan body aluminium, rotor plastic
Connection
3-pole clamp for 2.5mm², clamping torque 0.8Nm max.
Case
plastic according to UL94 V-0, light grey; weather proof and UV light resistant according UL746C (f1)
Filter mat
G3 acc. to DIN EN 779, filtering degree 85%
Filter material
synthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1;
moisture resistant to 100% RH, reusable - cleaning by
Operating / Storage temperature
- 45 oC do + 70 oC
Prot. type
IP43 (with the contribution of G3) / IP33 (without filter G3)
Protection class
I(earthed)
Approvals
UL intended; (230V only: VDE)

Important note
For reasons of pressure compensation the roof filter fan must always be operated in
combination with a passive intake filter (e.g. Art. No. 11803.0-00) or another filter fan (e.g. Art. No. 01803.0-00).

Roof Filter Fan RFP 018 Series

Art. No. Operating voltage Air volume,
free flow
Air volume,
free flow
Current
consumption
Average noise level
(DIN EN ISO 4871)
Depth in
enclosure
Enclosure
cut-out
Weight
(approx.)
01860.0-00 AC 230V, 50Hz 300m3/h
(with the contribution of G3)
400m3/h
(without filter G3)
68W 55dB (A) 52mm 250 x 250mm + 0.4 3.3kg
01861.0-00 AC 230V, 50Hz 500m3/h
(with the contribution of G3)
650m3/h
(without filter G3)
64W 67dB (A) 107mm 250 x 250mm + 0.4 2.6kg
01860.0-02 AC 120V, 60Hz 345m3/h
(with the contribution of G3)
460m3/h
(without filter G3)
60W 55dB (A) 52mm 250 x 250mm + 0.4 3.3kg
01861.0-02 AC 120V, 60Hz 575m3/h
(with the contribution of G3)
748m3/h
(without filter G3)
85W 67dB (A) 107mm 250 x 250mm
+ 0,4
2.6kg


Roof Exit Filter REP 118 Series
Art. No. Depth in enclosure Enclosure cut-out Weight (approx.) Filter mat Protection type
11860.0-00 11mm 250 x 250mm + 0.4 1.Okg G3 acc. to DIN EN 779, filtering degree 85% IP43 (z f. G3)/ IP 33 (bez f. G3)


Filter Mat FM 086
Filter mat 282 x 282mm
G3 (1 packing unit = 3 pcs.) Art. No. 08613.0-00


Roof fan (01860.0-xx)
Roof fan (01861.00-xx)
Komentarai (0)