![THERMAL RELAY TR800WEB. THERMAL RELAY TR800WEB.](https://www.dacpol.eu/7607-large_default/thermal-relay-tr800web.jpg)
![THERMAL RELAY TR800WEB. THERMAL RELAY TR800WEB.](https://www.dacpol.eu/7607-large_default/thermal-relay-tr800web.jpg)
Jūs turite būti prisijungę
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją
please use latin characters
The TR800Web can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser. No special software and no special instruction is necessary. The Universal-Relay TR800Web monitors and logs signals from up to 8 inputs. Up to 8 limits (one per input) can be programmed for each of the 4 output-relays. Thus e.g. alarm 1 can be activated when the temperature at a sensor (e.g. Pt100) at input 1 exceeds a limit or when the signal of a transmitter for pressure (e.g. 4-20 mA) at input 5 falls below a limit. It can also send an email when a limit is exceeded and/or when the signals falls short of the limit again. A day/night switchover allows to vary limits depending on daytime. In addition the device has an interface RS485 with the protocols Modbus and ZIEHL-standard.
Applications
The TR800Web is used where one or more of the following features a required:
8 Measuring inputs (every input individually programmable)
4 Alarms
Programmable via internet in web-browser
Interfaces:
Displays and Operating elements
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
The TR800Web can be connected to the internet or an intranet and operated via TCP/IP from a normal PC with a suitable browser. No special software and no special instruction is necessary. The Universal-Relay TR800Web monitors and logs signals from up to 8 inputs. Up to 8 limits (one per input) can be programmed for each of the 4 output-relays. Thus e.g. alarm 1 can be activated when the temperature at a sensor (e.g. Pt100) at input 1 exceeds a limit or when the signal of a transmitter for pressure (e.g. 4-20 mA) at input 5 falls below a limit. It can also send an email when a limit is exceeded and/or when the signals falls short of the limit again. A day/night switchover allows to vary limits depending on daytime. In addition the device has an interface RS485 with the protocols Modbus and ZIEHL-standard.
Applications
The TR800Web is used where one or more of the following features a required:
8 Measuring inputs (every input individually programmable)
4 Alarms
Programmable via internet in web-browser
Interfaces: