GSK (F) split-core current transformers can be used for a variety of measuring, revenue metering (billing) and protection tasks. They are easily mounted around existing busbar or cable systems. If the busbar systems or medium voltage cables are sufficiently insulated, these current transformers can be used for insulation levels higher than UM= 0,72kV. Split-core current transformers for outdoor use are also available on request.
The current transformers are made of soft magnetic, highly permeable cut wound cores. Each half of the core is uniformly wound for better detection of the magnetic field. Two plugs connect the two halves when mounted. Four socket-head cap screws with compression springs hold the two halves of the housing together, thus guaranteeing the correct pressure at the cut core surfaces.
The output terminals come equipped with M5 screws. Protection against accidental contact is provided by a transparent polycarbonate cap. The modular mould system of the GSK permits almost any combination of housing and window sizes. To guarantee the mechanical and electrical resistance of the transformers they are encapsulated in a cast-resin housing with polyurethane. The GSK split-core current transformers are equipped with two base plates as standard that allow them to be mounted in any position. They require no maintenance.
During the final inspection at ELEQ the current transformers are always subjected to a routine test in accordance with the relevant national and international standards
Caution: if current transformers are operated open-circuited on the secondary side, extremely high voltages can be generated with resultant damage to equipment and personnel!
General technical data
Rated primary current | 50.….10000A |
---|---|
Rated secondary current | 1A, 5A |
Rated frequency | 50Hz, 60Hz |
Rated burden | according to customers requirement |
Accuracy class | according to customers requirement |
Rated insulation level | 0,72/3/-kV |
Rated short-time thermal current | Minimum 100 x IN |
Standard | VDE, IEC, BC, ANSI itp. |
Dimensions GSK100 and 120
|
Possible sizes
|
Dimensions remaining GSK’s |
Possible sizes |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
GSK (F) split-core current transformers can be used for a variety of measuring, revenue metering (billing) and protection tasks. They are easily mounted around existing busbar or cable systems. If the busbar systems or medium voltage cables are sufficiently insulated, these current transformers can be used for insulation levels higher than UM= 0,72kV. Split-core current transformers for outdoor use are also available on request.
The current transformers are made of soft magnetic, highly permeable cut wound cores. Each half of the core is uniformly wound for better detection of the magnetic field. Two plugs connect the two halves when mounted. Four socket-head cap screws with compression springs hold the two halves of the housing together, thus guaranteeing the correct pressure at the cut core surfaces.
The output terminals come equipped with M5 screws. Protection against accidental contact is provided by a transparent polycarbonate cap. The modular mould system of the GSK permits almost any combination of housing and window sizes. To guarantee the mechanical and electrical resistance of the transformers they are encapsulated in a cast-resin housing with polyurethane. The GSK split-core current transformers are equipped with two base plates as standard that allow them to be mounted in any position. They require no maintenance.
During the final inspection at ELEQ the current transformers are always subjected to a routine test in accordance with the relevant national and international standards
Caution: if current transformers are operated open-circuited on the secondary side, extremely high voltages can be generated with resultant damage to equipment and personnel!
General technical data
Rated primary current | 50.….10000A |
---|---|
Rated secondary current | 1A, 5A |
Rated frequency | 50Hz, 60Hz |
Rated burden | according to customers requirement |
Accuracy class | according to customers requirement |
Rated insulation level | 0,72/3/-kV |
Rated short-time thermal current | Minimum 100 x IN |
Standard | VDE, IEC, BC, ANSI itp. |
Dimensions GSK100 and 120
|
Possible sizes
|
Dimensions remaining GSK’s |
Possible sizes |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|