The cast resin outdoor current transformer is capable to withstanding the outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The primary current is connected with an internal bus bar. The secondary windings are used for measurement and / or protection purposes, or optional with test winding
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ASCI C 57.13; BS 1675 |
Class of insulation | B |
Ith | 100 x IN (max.100kA) |
Idyn: | 2,5 x ITh (max. 125kA) |
Frequency : | 50Hz, 60Hz other frequency on request |
Rated insulation voltage | complying with the standard |
Secondary current | 1A; 5A; other current on request |
Burde / Class: | depending from number of cores accu-racy limit factors and the rated output |
Secondary terminal box: | with degree of protection IP64 Base |
Special model: | Secondary switch-over |
Type |
IGHF 12B 300 |
IGHF 24B 300 |
IGHF 36B 300 |
---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn[A] | 3000 | 3000 | 3000 |
Creepage distance [mm] | 409 | 480 | 1124 |
Max. number of cores | 4 | 5 | 5 |
Number of rips | 3 | 4 | 10 |
Weight [kg] | 46 | 48 | 56 |
Type | A | B | C | D | Sec. Terminals | Rippen |
---|---|---|---|---|---|---|
IGHF 12 |
300 | 300 | 350 | 500 | 8 | 3 |
IGHF 24 |
300 | 300 | 395 | 545 | 10 | 4 |
IGHF 36 |
300 | 300 | 542 | 692 | 10 | 10 |
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
The cast resin outdoor current transformer is capable to withstanding the outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The primary current is connected with an internal bus bar. The secondary windings are used for measurement and / or protection purposes, or optional with test winding
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ASCI C 57.13; BS 1675 |
Class of insulation | B |
Ith | 100 x IN (max.100kA) |
Idyn: | 2,5 x ITh (max. 125kA) |
Frequency : | 50Hz, 60Hz other frequency on request |
Rated insulation voltage | complying with the standard |
Secondary current | 1A; 5A; other current on request |
Burde / Class: | depending from number of cores accu-racy limit factors and the rated output |
Secondary terminal box: | with degree of protection IP64 Base |
Special model: | Secondary switch-over |
Type |
IGHF 12B 300 |
IGHF 24B 300 |
IGHF 36B 300 |
---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn[A] | 3000 | 3000 | 3000 |
Creepage distance [mm] | 409 | 480 | 1124 |
Max. number of cores | 4 | 5 | 5 |
Number of rips | 3 | 4 | 10 |
Weight [kg] | 46 | 48 | 56 |
Type | A | B | C | D | Sec. Terminals | Rippen |
---|---|---|---|---|---|---|
IGHF 12 |
300 | 300 | 350 | 500 | 8 | 3 |
IGHF 24 |
300 | 300 | 395 | 545 | 10 | 4 |
IGHF 36 |
300 | 300 | 542 | 692 | 10 | 10 |