Igwf - dabartiniai transformatoriai, vidutinės įtampos palaikymas

IGWF - Outdoor Current Transformer

The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.

 
Technical Data

 

Design Cast-resin insulated
Colour brown
In accordance to VDE 0414; IEC 60044; ANSI C 57.13; BS 1675
Class of insulation B
Ith: 1000 x IN (max. 100 kA);
Idyn 2.5 x ITh (max. 125 kA)
Frequency 50-60 Hz, other frequency on request
Rated insulation voltage: complying with the standard
Primary currenty see table
Secondary current: 5A; 1A; other current on request
Burde / Class depending on the number of cores, accuracy limit factors and the rated
output
Secondary terminal box with degree of protection IP64
Special model: Secondary switch-over


Type

IGWF 12
B 27

IGWF 24
B 27

IGWF 12
E 43

IGWF 24
E 44

IGWF 36
E 46

Insulation voltage [kV] 12/28/75 24/50/125 12/28/75 24/50/125 36/70/170
Max. Ipn [A] 1250 1250 2500 2500 2500
Creepage distance [mm] 560 560 610 780 1120
Max. number of cores 2 2 5 5 5
Weight [kg] 25 25 40 48 72


Dimensional drawing

IGWF - przekładniki prądowe napowietrzne, wsporcze średniego napięcia

Type A B C D E Sec. Terminals Shield

IGWF 12/24 B 27

250 180 325 310 240 6 7

IGWF 12 E 43

350 248 325 442 340 10 3

IGWF 24 E 44

350 248 375 442 340 10 4

IGWF 36 E 46

350 248 475 442 340 10 6

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

IGWF - Outdoor Current Transformer

The cast resin current transformer is capable to withstanding the aggravate outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The secondary windings are used for measurement and / or protection purposes, or for special use like testing winding.

 
Technical Data

 

Design Cast-resin insulated
Colour brown
In accordance to VDE 0414; IEC 60044; ANSI C 57.13; BS 1675
Class of insulation B
Ith: 1000 x IN (max. 100 kA);
Idyn 2.5 x ITh (max. 125 kA)
Frequency 50-60 Hz, other frequency on request
Rated insulation voltage: complying with the standard
Primary currenty see table
Secondary current: 5A; 1A; other current on request
Burde / Class depending on the number of cores, accuracy limit factors and the rated
output
Secondary terminal box with degree of protection IP64
Special model: Secondary switch-over


Type

IGWF 12
B 27

IGWF 24
B 27

IGWF 12
E 43

IGWF 24
E 44

IGWF 36
E 46

Insulation voltage [kV] 12/28/75 24/50/125 12/28/75 24/50/125 36/70/170
Max. Ipn [A] 1250 1250 2500 2500 2500
Creepage distance [mm] 560 560 610 780 1120
Max. number of cores 2 2 5 5 5
Weight [kg] 25 25 40 48 72


Dimensional drawing

IGWF - przekładniki prądowe napowietrzne, wsporcze średniego napięcia

Type A B C D E Sec. Terminals Shield

IGWF 12/24 B 27

250 180 325 310 240 6 7

IGWF 12 E 43

350 248 325 442 340 10 3

IGWF 24 E 44

350 248 375 442 340 10 4

IGWF 36 E 46

350 248 475 442 340 10 6