J2102A - Transformatorius apsaugo nuo svorio kilpos

J2102A – Common Mode Transformer

The simplest and most effective method for eliminating a ground loop is to add a wideband common mode transformer to the measurement, such as the Picotest J2102A Common Mode Transformer. The transformer for a low impedance PDN measurement must have very wide bandwidth, low loss and tight coupling, otherwise, the results will not be accurate over the measured frequency range. It is also important to maintain the 50 Ohm transmission line impedance through this transformer. The J2102A accomplishes this with ease.

 

Key features:

  • Greatly attenuates the effects of low frequency ground loops
  • Supports the 2 Port Shunt Thru impedance measurement required for Power Distribution Networks (PDN’s)
  • Maintains 50 Ohm transmission line integrity to approximately 500MHz
  • Works with all types of test equipment to eliminate ground loops, such as Network Analyzers, Oscilloscopes and Spectrum Analyzers

Rated data:

Recommended Bandwidth 1Hz…100MHz
Insertion Loss 1Hz…100MHz 0.2dB typ, 0.5dB max
Return Loss 1Hz…100MHz 20dB typ, 10dB min
Max Voltage 50V
Temperature Range 0…50°C
Maximum Altitude 1850m
Dimensions 109x90x51mm
Weight 0.210kg
Input BNC
Output BNC

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Pranešimas sėkmingai išsiųstas.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

J2102A – Common Mode Transformer

The simplest and most effective method for eliminating a ground loop is to add a wideband common mode transformer to the measurement, such as the Picotest J2102A Common Mode Transformer. The transformer for a low impedance PDN measurement must have very wide bandwidth, low loss and tight coupling, otherwise, the results will not be accurate over the measured frequency range. It is also important to maintain the 50 Ohm transmission line impedance through this transformer. The J2102A accomplishes this with ease.

 

Key features:

  • Greatly attenuates the effects of low frequency ground loops
  • Supports the 2 Port Shunt Thru impedance measurement required for Power Distribution Networks (PDN’s)
  • Maintains 50 Ohm transmission line integrity to approximately 500MHz
  • Works with all types of test equipment to eliminate ground loops, such as Network Analyzers, Oscilloscopes and Spectrum Analyzers

Rated data:

Recommended Bandwidth 1Hz…100MHz
Insertion Loss 1Hz…100MHz 0.2dB typ, 0.5dB max
Return Loss 1Hz…100MHz 20dB typ, 10dB min
Max Voltage 50V
Temperature Range 0…50°C
Maximum Altitude 1850m
Dimensions 109x90x51mm
Weight 0.210kg
Input BNC
Output BNC