HTR 50 iki 500-SB serijos keitikliai
  • HTR 50 iki 500-SB serijos keitikliai

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: LEM

HTR 50 iki 500-SB serijos keitikliai

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

 HTR 50-SBHTR 100-SBHTR 200-SBHTR 300-SBHTR 400-SBHTR 500-SB
Primary nominal current rmsIPNSK 50A 100A 200A 300A 400A 500A
Primary current,measuring range I Pmax ±100A ±200A ±400A ±600A ±800A ±1000A


Mechanical characteristics
 
• General tolerance
± 1 mm
• Primary through hole
Ø21 mm
• Fastening
2 holes Ø3.2
• Montaż panelowy
4 holes Ø3,2
Distance between holes axes
50 x 36 mm lub 1 hole Ø3.2 iand one spigot Ø2.5
Distance between hole and sigot axes
36 mm
• Connection of secondary
MOLEX 5046-04/AG
 
Remarks
VOUT is positive when IP flows in the direction of the arrow.
he return busbar and primary conductor elbow must be located at least at 2.5 x window length more far away from the transducer case.
Temperature of the primary busbar cannot exceed 90°C.
Dynamic performances are best with a primary busbar completely filling the primary aperture.
This is a standard model. For different versions (supply voltages, different output, unidirectional measurements ...), please contact us.

Dimensions[mm]

LEM HTR 50 DO 500-SB