Measurement, visualization and recording of over 300 parameters of 3-phase balanced or unbalanced power network
Inputs | |||
---|---|---|---|
Kind of input | Measuring range | Parameters | Basic error |
Voltage input | 57,7/100 V, 230/400 V or 400/690 V |
0,05...1,2 Un | ± 0,2% |
Current input | 1 A lub 5 A | 0,005...1,2 In | ± 0,2% |
Logic input | 0/5...24 V d.c. | switch frequency up to 50 Hz |
Outputs | |
---|---|
Kind of output | Properties |
Analog output | 4 programmable current outputs of 0/4...20 mA, load resistance < 500 Ω |
Relay output | 6 programmable electromagnetic relays, voltageless NOC contacts, load capacity: 250 V a.c./1 A a.c. |
Output to supply object transducers | 2 outputs of 24 V d.c./30 mA |
Digital interfaces | |
---|---|
Interface type | Properties |
RS-485 | 2 interfaces: MODBUS Slave and Master, baud rate: 300…256000 bit/s, transmission mode ASCII/RTU |
USB | Device V.1.1, USBB-G socket |
Ethernet | 10 Base-T, RJ45socket, Modbus Slave TCP/IP |
Rated operating conditions | ||
---|---|---|
Supply voltage | 85...230...253 V a.c./d.c., 40...400 Hz a.c | Power consumption ≤ 30 VA |
Ambient temperature | Work 0...23...50°C | Storage:: - 20...60°C |
Relative humidity | < 70% | Condensation inadmissible |
Reaction against | supply decays | Data and device state preservation |
powrót zasilania: | Continuation of device work | |
Short term load (5s) | 2 Un (max. 1000 V) | 10 In |
Casing protection grade | From frontal side: IP 65 | From terminal side: IP20 |
Safety requirements | Installation category: II | EN 61010-1 |
Pollution grade: 2 | ||
Maximum phase-to-earth operating voltage |
From the measuring system, relays and supply: 500 V | |
For RS-485 and USB interfaces: 50 V |
Measuring ranges and admissible basic conversion errors | |||
---|---|---|---|
Measuring quantity | Range | Basic error | Remarks |
Voltage U | 57,73 / 100,0 V (Ku = 1) 230,0 / 400,0 V (Ku = 1) 400,0 / 690,0 V (Ku = 1) 400,0 kV (Ku ≠ 1) |
± 0,2 % | Ku = 1...4000 |
Current I | 1,000 A (Ki = 1) 5,000 A (Ki = 1) 100,0 kA (Ki ≠ 1) |
± 0,2 % | Ki = 1...20000 |
Active power P Mean active power Pav |
0,0… (-) 6000,0 W 999,00 MW (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
Apparent power S | 0,0…6000,0 VA 999,00 MVA (Ku ≠ 1, Ki ≠ 1) | ± 0,5 % | |
Reactive power Q | 0,0…(-) 6000,0 VA 999,00 MV (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
Active power factor PF | -1,000…0…1,000 | ± 0,5 % | PF = Power Factor = P/S |
Coefficient tφ | -10,00…0…10,00 | ± 1 % | Ratio of active power to reactive |
φ angle between U and I | -180°...180° | ± 0,5 % | Evaluated from the power triangle |
Frequency f | 45,00...66,00 Hz | ± 0,1 % | |
THD U, THD I Harmonics U, I (up to 51) |
0…200,0 % 0…100,0 % | ± 2 % | Error in the range 10…120 % U,I |
PST, PLT | 0..20 | ± 0,5 % | in range of 0.05..35 Hz |
Active energy EnP | 0…(-) 99 999 999,9 kWh | ± 0,5 % | |
Reactive energy EnQ | 0… (-) 99 999 999,9 kvarh | ± 0,5 % |
where:
Ku voltage transformer ratio
Ki current transformer ratio
THD U total coefficient of voltage harmonic distortion
THD I total coefficient of current harmonic distortion,
EXAMPLE OF ORDER:
The code ND1 - 2 1 00 E 0 means:
ND1 - analyser of 3-phase power network
parameters of ND1 type
2 - current input: 5 A
1 - voltage input: 57.7/100 V
00 - standard version
E - English language
0 - without extra quality requirements.
NOTE:
Each ND1 analyser is equiped with 6 alarms (electromecanic relays), 4 analog outputs, 12 logic inputs and Ethernet interface..
Various forms of data display: ,
Manual and automatic switching between screens.
Housing view from frontal side | Housing view from rear view |
1301-130-903 – wire MLS R, 2m, black
1301-130-902 – crocodile terminal AK-2B 2540, black
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
Measurement, visualization and recording of over 300 parameters of 3-phase balanced or unbalanced power network
Inputs | |||
---|---|---|---|
Kind of input | Measuring range | Parameters | Basic error |
Voltage input | 57,7/100 V, 230/400 V or 400/690 V |
0,05...1,2 Un | ± 0,2% |
Current input | 1 A lub 5 A | 0,005...1,2 In | ± 0,2% |
Logic input | 0/5...24 V d.c. | switch frequency up to 50 Hz |
Outputs | |
---|---|
Kind of output | Properties |
Analog output | 4 programmable current outputs of 0/4...20 mA, load resistance < 500 Ω |
Relay output | 6 programmable electromagnetic relays, voltageless NOC contacts, load capacity: 250 V a.c./1 A a.c. |
Output to supply object transducers | 2 outputs of 24 V d.c./30 mA |
Digital interfaces | |
---|---|
Interface type | Properties |
RS-485 | 2 interfaces: MODBUS Slave and Master, baud rate: 300…256000 bit/s, transmission mode ASCII/RTU |
USB | Device V.1.1, USBB-G socket |
Ethernet | 10 Base-T, RJ45socket, Modbus Slave TCP/IP |
Rated operating conditions | ||
---|---|---|
Supply voltage | 85...230...253 V a.c./d.c., 40...400 Hz a.c | Power consumption ≤ 30 VA |
Ambient temperature | Work 0...23...50°C | Storage:: - 20...60°C |
Relative humidity | < 70% | Condensation inadmissible |
Reaction against | supply decays | Data and device state preservation |
powrót zasilania: | Continuation of device work | |
Short term load (5s) | 2 Un (max. 1000 V) | 10 In |
Casing protection grade | From frontal side: IP 65 | From terminal side: IP20 |
Safety requirements | Installation category: II | EN 61010-1 |
Pollution grade: 2 | ||
Maximum phase-to-earth operating voltage |
From the measuring system, relays and supply: 500 V | |
For RS-485 and USB interfaces: 50 V |
Measuring ranges and admissible basic conversion errors | |||
---|---|---|---|
Measuring quantity | Range | Basic error | Remarks |
Voltage U | 57,73 / 100,0 V (Ku = 1) 230,0 / 400,0 V (Ku = 1) 400,0 / 690,0 V (Ku = 1) 400,0 kV (Ku ≠ 1) |
± 0,2 % | Ku = 1...4000 |
Current I | 1,000 A (Ki = 1) 5,000 A (Ki = 1) 100,0 kA (Ki ≠ 1) |
± 0,2 % | Ki = 1...20000 |
Active power P Mean active power Pav |
0,0… (-) 6000,0 W 999,00 MW (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
Apparent power S | 0,0…6000,0 VA 999,00 MVA (Ku ≠ 1, Ki ≠ 1) | ± 0,5 % | |
Reactive power Q | 0,0…(-) 6000,0 VA 999,00 MV (Ku ≠ 1, Ki ≠ 1) |
± 0,5 % | |
Active power factor PF | -1,000…0…1,000 | ± 0,5 % | PF = Power Factor = P/S |
Coefficient tφ | -10,00…0…10,00 | ± 1 % | Ratio of active power to reactive |
φ angle between U and I | -180°...180° | ± 0,5 % | Evaluated from the power triangle |
Frequency f | 45,00...66,00 Hz | ± 0,1 % | |
THD U, THD I Harmonics U, I (up to 51) |
0…200,0 % 0…100,0 % | ± 2 % | Error in the range 10…120 % U,I |
PST, PLT | 0..20 | ± 0,5 % | in range of 0.05..35 Hz |
Active energy EnP | 0…(-) 99 999 999,9 kWh | ± 0,5 % | |
Reactive energy EnQ | 0… (-) 99 999 999,9 kvarh | ± 0,5 % |
where:
Ku voltage transformer ratio
Ki current transformer ratio
THD U total coefficient of voltage harmonic distortion
THD I total coefficient of current harmonic distortion,
EXAMPLE OF ORDER:
The code ND1 - 2 1 00 E 0 means:
ND1 - analyser of 3-phase power network
parameters of ND1 type
2 - current input: 5 A
1 - voltage input: 57.7/100 V
00 - standard version
E - English language
0 - without extra quality requirements.
NOTE:
Each ND1 analyser is equiped with 6 alarms (electromecanic relays), 4 analog outputs, 12 logic inputs and Ethernet interface..
Various forms of data display: ,
Manual and automatic switching between screens.
Housing view from frontal side | Housing view from rear view |
1301-130-903 – wire MLS R, 2m, black
1301-130-902 – crocodile terminal AK-2B 2540, black
Jūsų atsiliepimo įvertinimas negali būti išsiųstas
Pranešti apie komentarą
Pranešimas apie atsiliepimą išsiųstas
Jūsų pranešimas apie atsiliepimą neišsiųstas
Parašyti savo atsiliepimą
Atsiliepimas išsiųstas
Jūsų atsiliepimas neišsiųstas