Separation between PLC analog inputs
Inputs | ||||
---|---|---|---|---|
Input: | Measuring range: | Parameters | Overloads | Error |
Current: -20...20mA |
-20...20 mA; -5...5 mA; 0...20 mA 0...5 mA 4...20 mA |
Resistance:: 12 Ω ± 1% | Short duration overload: 5 In Sustained overload 1.1 In |
Conversion class: 0.2 |
Voltage: -10...10 V |
-10...10 V; -5...5 V -1...1 V 0...10 V 0...5 V 0...1 V |
Resistance: > 1 M Ω | Short duration overload: 5 Un Sustained overload 1.2 Un |
Outputs | |||
---|---|---|---|
Output kind | Output kind | Remarks | |
-20...20 mA | Rload ≥ 500 Ω | Conversion class: 0,2 | |
-10...10 V | Rload ≥ 500 Ω | ||
External Features | |||
Weight | 22,5 x 120 x 100 mm | ||
Dimensions | < 0,125 kg | ||
Protection grade (acc. to EN 60529) | ensured by the housing:IP 40 | from the terminal side: IP 20 | |
Fixing | on a 35 mm rail | acc. to EN 60715 | |
Rated operating conditions | |||
Supply voltage | 85...253 V a.c. (45...65Hz) d.c. lub 20...40 V a.c. (45...65 Hz) d.c. |
power consumption: < 4 VA | |
Temperature | ambient: -20...23...55°C | storage: -25...85°C | |
Relative humidity | < 95% | inadmissible condensation | |
Operating position | any | ||
Preheating time | 10 min | ||
Averaging time of the measurement | ≥ 0,1 s | ||
Response time of the separator | ≥ 0,1 s | ||
Safety and compatibility requirements | |||
Electromagnetic compatibility | Noise immunity | acc. to EN 61000-6-2 | |
Noise emissions | acc. to EN 61000-6-4 | ||
Isolation between circuits | basic | acc. to EN 61010-1 | |
Pollution grade | 2 | ||
Installation category | III | ||
Maximal phase-to-earth operating voltage |
for the supply circuit: 300 V (version: 230 V) | ||
for the measuring input: 50 V | |||
for the output: 50 V | |||
Altitude above sea level | < 2000 m |
Electrical connection diagram of the P20G separator
Table 1. Ordering codes: | ||||||
---|---|---|---|---|---|---|
P27G | XX | XX | X | XX | X | X |
Input: kind of programmed input: see table 2 |
XX | |||||
Output: kind of programmed output: see table 2 |
XX | |||||
Supply: 85...253 V a.c./d.c. 20...40 V a.c./d.c. |
1 2 |
|||||
Version: standard non-standard settings custom-made* |
00 NS XX |
|||||
Language: Polish English other* |
P E X |
|||||
Acceptance tests: without extra quality inspection requiremnts with an extra quality inspection certificate acc. to customer’s request* |
0 1 X |
Table 2. Coding of the P20G separator kind of input and output | ||
---|---|---|
Range | Input code | Output code |
0...1 V | 01 | 01** |
0...5 V | 02 | 02 |
0...10 V | 03 | 03 |
±1 V | 04 | 04** |
±5 V | 05 | 05 |
±10 V | 06 | 06 |
0...5 mA | 07 | 07** |
0...20 mA | 08 | 08 |
±5 mA | 09 | 09** |
±20 mA | 10 | 10 |
4...20 mA | 11 | 11 |
Custom-made version* | XX | XX |
Order example:
The code P20G - 08 06 1 00 E 1 means:
P20G - Separator of analog signals (U d.c. and I d.c.)
08 - kind of programmed input: 0...20 mA
06 - kind of programmed output: ±10 V
1 - supply voltage: 85...253 V a.c./d.c.
00 - standard version
E - English language
1 - with an extra quality inspection requirements
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
Separation between PLC analog inputs
Inputs | ||||
---|---|---|---|---|
Input: | Measuring range: | Parameters | Overloads | Error |
Current: -20...20mA |
-20...20 mA; -5...5 mA; 0...20 mA 0...5 mA 4...20 mA |
Resistance:: 12 Ω ± 1% | Short duration overload: 5 In Sustained overload 1.1 In |
Conversion class: 0.2 |
Voltage: -10...10 V |
-10...10 V; -5...5 V -1...1 V 0...10 V 0...5 V 0...1 V |
Resistance: > 1 M Ω | Short duration overload: 5 Un Sustained overload 1.2 Un |
Outputs | |||
---|---|---|---|
Output kind | Output kind | Remarks | |
-20...20 mA | Rload ≥ 500 Ω | Conversion class: 0,2 | |
-10...10 V | Rload ≥ 500 Ω | ||
External Features | |||
Weight | 22,5 x 120 x 100 mm | ||
Dimensions | < 0,125 kg | ||
Protection grade (acc. to EN 60529) | ensured by the housing:IP 40 | from the terminal side: IP 20 | |
Fixing | on a 35 mm rail | acc. to EN 60715 | |
Rated operating conditions | |||
Supply voltage | 85...253 V a.c. (45...65Hz) d.c. lub 20...40 V a.c. (45...65 Hz) d.c. |
power consumption: < 4 VA | |
Temperature | ambient: -20...23...55°C | storage: -25...85°C | |
Relative humidity | < 95% | inadmissible condensation | |
Operating position | any | ||
Preheating time | 10 min | ||
Averaging time of the measurement | ≥ 0,1 s | ||
Response time of the separator | ≥ 0,1 s | ||
Safety and compatibility requirements | |||
Electromagnetic compatibility | Noise immunity | acc. to EN 61000-6-2 | |
Noise emissions | acc. to EN 61000-6-4 | ||
Isolation between circuits | basic | acc. to EN 61010-1 | |
Pollution grade | 2 | ||
Installation category | III | ||
Maximal phase-to-earth operating voltage |
for the supply circuit: 300 V (version: 230 V) | ||
for the measuring input: 50 V | |||
for the output: 50 V | |||
Altitude above sea level | < 2000 m |
Electrical connection diagram of the P20G separator
Table 1. Ordering codes: | ||||||
---|---|---|---|---|---|---|
P27G | XX | XX | X | XX | X | X |
Input: kind of programmed input: see table 2 |
XX | |||||
Output: kind of programmed output: see table 2 |
XX | |||||
Supply: 85...253 V a.c./d.c. 20...40 V a.c./d.c. |
1 2 |
|||||
Version: standard non-standard settings custom-made* |
00 NS XX |
|||||
Language: Polish English other* |
P E X |
|||||
Acceptance tests: without extra quality inspection requiremnts with an extra quality inspection certificate acc. to customer’s request* |
0 1 X |
Table 2. Coding of the P20G separator kind of input and output | ||
---|---|---|
Range | Input code | Output code |
0...1 V | 01 | 01** |
0...5 V | 02 | 02 |
0...10 V | 03 | 03 |
±1 V | 04 | 04** |
±5 V | 05 | 05 |
±10 V | 06 | 06 |
0...5 mA | 07 | 07** |
0...20 mA | 08 | 08 |
±5 mA | 09 | 09** |
±20 mA | 10 | 10 |
4...20 mA | 11 | 11 |
Custom-made version* | XX | XX |
Order example:
The code P20G - 08 06 1 00 E 1 means:
P20G - Separator of analog signals (U d.c. and I d.c.)
08 - kind of programmed input: 0...20 mA
06 - kind of programmed output: ±10 V
1 - supply voltage: 85...253 V a.c./d.c.
00 - standard version
E - English language
1 - with an extra quality inspection requirements
Jūsų atsiliepimo įvertinimas negali būti išsiųstas
Pranešti apie komentarą
Pranešimas apie atsiliepimą išsiųstas
Jūsų pranešimas apie atsiliepimą neišsiųstas
Parašyti savo atsiliepimą
Atsiliepimas išsiųstas
Jūsų atsiliepimas neišsiųstas