Saliagars® 105 ° C ul. Cul
  • Saliagars® 105 ° C ul. Cul

Nuotraukos yra skirtos tik informaciniams tikslams. Peržiūrėkite produkto specifikaciją

please use latin characters

Gamintojas: OMERIN

Saliagars® 105 ° C ul. Cul

SILICABLE® 105 °C UL cUL

Characteristics

• Continuous operating temperatures: -60 °C to +105 °C
• Good resistance to thermal shock and UV.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Produkt:

• All colours including two-coloured.
• Stranding of conducting cores: contact us.

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.
• Halogen-free: IEC 60754-1 / EN 60754-1.

Applications

• Cabling for household electrical heating appliances, rotating machines, lighting.
• Industrial cabling in hot atmospheres.

Options

• Other nominal cross-sections: contact us.


1 • Bare copper or tin-plated core.
2 • Insulation: Silicone rubber.


Style  3232 3243 3171
105 °C -300 V 105 °C - 300 V 105 °C -600 V
Nominal cross-section Avg thickness of insulation Nominal diameter* Avg thickness of insulation Nominal diameter* Avg thickness of insulation Nominal diameter*
AWG [mm2] [mm] [mm] [mm]
26 0.13 0.38 1.2 0.38 1.3 0.76 2.0
24 0.22 0.38 1.4 0.38 1.5 0.76 2.2
22 0.34 0.38 1.6 0.38 1.6 0.76 2.4
0.5 0.38 1.7 0.38 1.8 0.76 2.5
20 0.6 0.38 1.8 0.38 1.9 0.76 2.6
0.75 0.38 1.9 0.38 2.0 0.76 2.7
18 0.93 0.38 2.0 0.38 2.1 0.76 2.8
1 0.38 2.1 0.38 2.2 0.76 2.9
16 1.34 0.38 2.3 0.38 2.4 0.76 3.1
1.5 0.38 2.4 0.38 2.5 0.76 3.1
14 0.76 3.6
2.5 0.76 3.8
12 0.76 4.1
4 0.76 4.4
Conducting metal B BF (Ø 0.05 mm) BF (Ø 0.05 mm)

* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.

KEY

Conducting metals
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27%



AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

SILICABLE® 105 °C UL cUL

Characteristics

• Continuous operating temperatures: -60 °C to +105 °C
• Good resistance to thermal shock and UV.
• Rated voltage: as per style no.
• Test voltage: 10 x Rated voltage.

Produkt:

• All colours including two-coloured.
• Stranding of conducting cores: contact us.

Approvals - standards

• UL approval as per standard UL 758 - File no.: E101965.
• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965.
• “Horizontal flame test” as per UL approval.
• “FT2 flame rating” as per cUL approval.
• Halogen-free: IEC 60754-1 / EN 60754-1.

Applications

• Cabling for household electrical heating appliances, rotating machines, lighting.
• Industrial cabling in hot atmospheres.

Options

• Other nominal cross-sections: contact us.


1 • Bare copper or tin-plated core.
2 • Insulation: Silicone rubber.


Style  3232 3243 3171
105 °C -300 V 105 °C - 300 V 105 °C -600 V
Nominal cross-section Avg thickness of insulation Nominal diameter* Avg thickness of insulation Nominal diameter* Avg thickness of insulation Nominal diameter*
AWG [mm2] [mm] [mm] [mm]
26 0.13 0.38 1.2 0.38 1.3 0.76 2.0
24 0.22 0.38 1.4 0.38 1.5 0.76 2.2
22 0.34 0.38 1.6 0.38 1.6 0.76 2.4
0.5 0.38 1.7 0.38 1.8 0.76 2.5
20 0.6 0.38 1.8 0.38 1.9 0.76 2.6
0.75 0.38 1.9 0.38 2.0 0.76 2.7
18 0.93 0.38 2.0 0.38 2.1 0.76 2.8
1 0.38 2.1 0.38 2.2 0.76 2.9
16 1.34 0.38 2.3 0.38 2.4 0.76 3.1
1.5 0.38 2.4 0.38 2.5 0.76 3.1
14 0.76 3.6
2.5 0.76 3.8
12 0.76 4.1
4 0.76 4.4
Conducting metal B BF (Ø 0.05 mm) BF (Ø 0.05 mm)

* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.

KEY

Conducting metals
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27%



AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified

Komentarai (0)