SILICABLE NVS ir NVSL -60°C iki +350°C

Characteristics

• Continuous operating temperatures: -60 °C to +350 °C
• Excellent resistance to thermal shocks and oxidization of core.
• Rated voltage:
      NVS: 300/500V
      NVSL: 300/300V
• Test voltage:
      NVS: 2000V
      NVSL: 1500V

Standard products

• Standard colour: brown.
• Other colours on request including yellow/green.

Approvals - standards

• nikel typ 200, zgodne z normami DIN 17753, DIN 17740 i ASTM B 160,
• VERITAS approval certificates: > No. BV 153552. > No. BV 256192.
• VDE test report no. 9296-5950-0001/ 32YAT F42/sld-Fc.

Applications

• Cabling for heating resistors, cartridges, bands and plates.
• Domestic electrical heating appliances: kitchens, professional ovens, etc
• Machines for thermoplastics or rubber.
• Industrial furnaces and air ovens

Options

• Reduced outer diameters: ref. NVSL (See details of this option below).
• Fibreglass outer braid coated with PTFE varnish: ref. NVF.
• Other nominal cross-sections: contact us.
• Other core stranding: contact us.

1 • Stranded or flexible nickel core
2 • Impregnated fibreglass lappings.
3 • Silicone-coated fibreglass braid.

Conducting core

INSULATED WIRE OR CABLE

Nominal cross-section
[mm2]
Nominal stranding Maximum linear resistance at
20 °C
[Ω/km]
Nominal diameter
[mm]
Approximate linear weight
[kg/km]
0,22 7 x 0,20 573 1,4 4,6
0,25 8 x 0,20 503 1,9 5,7
0,5 7 x 0,30 229 2,1 8,8
0,75 11 x 0,30 156 2,4 11,9
1 14 x 0,30 115 2,5 14,5
1,34 19 x 0,30 93,1 2,6 15,9
1,5 21 x 0,30 77,2 2,8 19,1
2 29 x 0,30 58,0 3,0 22,1
2,5 35 x 0,30 47,2 3,2 29,3
4 56 x 0,30 31,5 4,3 47,4
6 84 x 0,30 21,0 4,8 67,5
8 119 x 0,30 15,5 5,8 82,3
10 140 x 0,30 12,1 6,8 106
16 224 x 0,30 7,72 8,2 192
25 354 x 0,30 4,97 10,1 302
35 495 x 0,30 3,53 12,0 395
50 707 x 0,30 2,46 13,2 556
70 999 x 0,30 1,73 16,3 785

Option • NVSL

Conducting core

INSULATED WIRE OR CABLE

Nominal cross-section
[mm2]
Nominal stranding Maximum linear resistance at 
20 °C
[Ω/km]
Nominal diameter
[mm]
Approximate linear weight
[kg/km]
0,22 7 x 0,20 573 1,2 3,8
0,25 8 x 0,20 503 1,3 4,1
0,34 11 x 0,20 366 1,4 5,1
0,5 7 x 0,30 229 1,4 6,2
0,75 11 x 0,30 156 1,8 9,0
1 14 x 0,30 115 2,1 10,9
1,34 19 x 0,30 93,1 2,3 14,5
1,5 21 x 0,30 77,2 2,5 15,2
2 29 x 0,30 58,0 2,7 20,7
2,5 35 x 0,30 47,2 3,0 24,5
4 56 x 0,30 31,5 3,6 38,6
6 84 x 0,30 21,0 4,4 57,7

Atsiųskite užklausą

Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?

Susisiekite su mumis
KLAUSKITE PRODUKTO close
Dėkojame, kad atsiuntėte žinutę. Atsakysime kuo greičiau.
KLAUSKITE PRODUKTO close
Naršyti

Pridėti į norų sąrašą

tu turi būti prisijungęs

Characteristics

• Continuous operating temperatures: -60 °C to +350 °C
• Excellent resistance to thermal shocks and oxidization of core.
• Rated voltage:
      NVS: 300/500V
      NVSL: 300/300V
• Test voltage:
      NVS: 2000V
      NVSL: 1500V

Standard products

• Standard colour: brown.
• Other colours on request including yellow/green.

Approvals - standards

• nikel typ 200, zgodne z normami DIN 17753, DIN 17740 i ASTM B 160,
• VERITAS approval certificates: > No. BV 153552. > No. BV 256192.
• VDE test report no. 9296-5950-0001/ 32YAT F42/sld-Fc.

Applications

• Cabling for heating resistors, cartridges, bands and plates.
• Domestic electrical heating appliances: kitchens, professional ovens, etc
• Machines for thermoplastics or rubber.
• Industrial furnaces and air ovens

Options

• Reduced outer diameters: ref. NVSL (See details of this option below).
• Fibreglass outer braid coated with PTFE varnish: ref. NVF.
• Other nominal cross-sections: contact us.
• Other core stranding: contact us.

1 • Stranded or flexible nickel core
2 • Impregnated fibreglass lappings.
3 • Silicone-coated fibreglass braid.

Conducting core

INSULATED WIRE OR CABLE

Nominal cross-section
[mm2]
Nominal stranding Maximum linear resistance at
20 °C
[Ω/km]
Nominal diameter
[mm]
Approximate linear weight
[kg/km]
0,22 7 x 0,20 573 1,4 4,6
0,25 8 x 0,20 503 1,9 5,7
0,5 7 x 0,30 229 2,1 8,8
0,75 11 x 0,30 156 2,4 11,9
1 14 x 0,30 115 2,5 14,5
1,34 19 x 0,30 93,1 2,6 15,9
1,5 21 x 0,30 77,2 2,8 19,1
2 29 x 0,30 58,0 3,0 22,1
2,5 35 x 0,30 47,2 3,2 29,3
4 56 x 0,30 31,5 4,3 47,4
6 84 x 0,30 21,0 4,8 67,5
8 119 x 0,30 15,5 5,8 82,3
10 140 x 0,30 12,1 6,8 106
16 224 x 0,30 7,72 8,2 192
25 354 x 0,30 4,97 10,1 302
35 495 x 0,30 3,53 12,0 395
50 707 x 0,30 2,46 13,2 556
70 999 x 0,30 1,73 16,3 785

Option • NVSL

Conducting core

INSULATED WIRE OR CABLE

Nominal cross-section
[mm2]
Nominal stranding Maximum linear resistance at 
20 °C
[Ω/km]
Nominal diameter
[mm]
Approximate linear weight
[kg/km]
0,22 7 x 0,20 573 1,2 3,8
0,25 8 x 0,20 503 1,3 4,1
0,34 11 x 0,20 366 1,4 5,1
0,5 7 x 0,30 229 1,4 6,2
0,75 11 x 0,30 156 1,8 9,0
1 14 x 0,30 115 2,1 10,9
1,34 19 x 0,30 93,1 2,3 14,5
1,5 21 x 0,30 77,2 2,5 15,2
2 29 x 0,30 58,0 2,7 20,7
2,5 35 x 0,30 47,2 3,0 24,5
4 56 x 0,30 31,5 3,6 38,6
6 84 x 0,30 21,0 4,4 57,7
Komentarai (0)