Characteristics • Continuous operating temperatures: -10 °C to +150 °C• Good resistance to common chemical influences and impregnating varnishes. • Rated voltage: as per style no. • Test voltage: 10 x Rated voltage. Standard products • Standard insulation colours: white, black, blue, brown, red or yellow/green.Approvals - standards • UL approval as per standard UL 758 - File no.: E101965.• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965. • “Horizontal flame test” as per UL approval. • “FT2 flame rating” as per cUL approval. Applications • Class F cabling for electric motors.• Lights • Industrial cabling in hot atmospheres up to +150 °C. Options • Nickel-plated copper core: contact us.• Other colours: contact us. • Other nominal cross-sections: contact us. • Other options: contact us. |
1 • Flexible bare copper or tin-plated core |
Nominal cross-section | ||||
---|---|---|---|---|
AWG | [mm2] | Nominal stranding | Avg thickness of insulation (mm) | Nominal diameter* (mm) |
22 | 0.34 | 19 x 0.15 | 0,76 | 2.35 |
- | 0.5 | 19 x 0.18 | 0,76 | 2.5 |
20 | 0,60 | 19 x 0,20 | 0,76 | 2,6 |
- | 0.75 | 24 x 0.20 | 0,76 | 2.7 |
18 | 0.93 | 19 x 0.25 | 0,76 | 2.8 |
- | 1 | 32 x 0.20 | 0,76 | 2.9 |
16 | 1.34 | 19 x 0.30 | 0,76 | 3.1 |
- | 1.5 | 30 x 0.25 | 0,76 | 3.15 |
14 | - | 19 x 0.37 | 0.76 | 3.4 |
- | 2.5 | 50 x 0.25 | 0.76 | 3.6 |
12 | - | 37 x 0.34 | 0.76 | 4.0 |
- | 4 | 52 x 0.30 | 0.76 | 4.1 |
10 | - | 37 x 0.43 | 0.76 | 4.7 |
- | 6 | 84 x 0.30 | 0.76 | 4.8 |
8 | - | 70 x 0.40 | 1.14 | 6.3 |
- | 10 | 77 x 0.40 | 1.14 | 7.0 |
6 | - | 105 x 0.40 | 1.52 | 8.4 |
- | 16 | 119 x 0.40 | 1.52 | 8.8 |
4 | - | 168 x 0.40 | 1.52 | 9.8 |
- | 25 | 196 x 0.40 | 1.52 | 10.4 |
2 | 35 | 259 x 0.40 | 2.04 | 11.7 |
1 | - | 342 x 0.40 | 2.04 | 13.6 |
- | 50 | 370 x 0.40 | 2.04 | 14.3 |
1/0 | - | 425 x 0.40 | 2.04 | 15.0 |
2/0 | 70 | 340 x 0.50 | 2.04 | 16.5 |
3/0 | - | 434 x 0.50 | 2.04 | 17.7 |
- | 95 | 475 x 0.50 | 2.04 | 18.7 |
4/0 | - | 546 x 0.50 | 2.04 | 19.6 |
conducting metal | BCDEFG |
KEY
Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified
Ar Jūs domina šis produktas? Ar Jums reikia papildomos informacijos ar individualaus pasiūlymo?
tu turi būti prisijungęs
Characteristics • Continuous operating temperatures: -10 °C to +150 °C• Good resistance to common chemical influences and impregnating varnishes. • Rated voltage: as per style no. • Test voltage: 10 x Rated voltage. Standard products • Standard insulation colours: white, black, blue, brown, red or yellow/green.Approvals - standards • UL approval as per standard UL 758 - File no.: E101965.• cUL approval (CSA) as per standard C22.2 No. 210 - File no.: E101965. • “Horizontal flame test” as per UL approval. • “FT2 flame rating” as per cUL approval. Applications • Class F cabling for electric motors.• Lights • Industrial cabling in hot atmospheres up to +150 °C. Options • Nickel-plated copper core: contact us.• Other colours: contact us. • Other nominal cross-sections: contact us. • Other options: contact us. |
1 • Flexible bare copper or tin-plated core |
Nominal cross-section | ||||
---|---|---|---|---|
AWG | [mm2] | Nominal stranding | Avg thickness of insulation (mm) | Nominal diameter* (mm) |
22 | 0.34 | 19 x 0.15 | 0,76 | 2.35 |
- | 0.5 | 19 x 0.18 | 0,76 | 2.5 |
20 | 0,60 | 19 x 0,20 | 0,76 | 2,6 |
- | 0.75 | 24 x 0.20 | 0,76 | 2.7 |
18 | 0.93 | 19 x 0.25 | 0,76 | 2.8 |
- | 1 | 32 x 0.20 | 0,76 | 2.9 |
16 | 1.34 | 19 x 0.30 | 0,76 | 3.1 |
- | 1.5 | 30 x 0.25 | 0,76 | 3.15 |
14 | - | 19 x 0.37 | 0.76 | 3.4 |
- | 2.5 | 50 x 0.25 | 0.76 | 3.6 |
12 | - | 37 x 0.34 | 0.76 | 4.0 |
- | 4 | 52 x 0.30 | 0.76 | 4.1 |
10 | - | 37 x 0.43 | 0.76 | 4.7 |
- | 6 | 84 x 0.30 | 0.76 | 4.8 |
8 | - | 70 x 0.40 | 1.14 | 6.3 |
- | 10 | 77 x 0.40 | 1.14 | 7.0 |
6 | - | 105 x 0.40 | 1.52 | 8.4 |
- | 16 | 119 x 0.40 | 1.52 | 8.8 |
4 | - | 168 x 0.40 | 1.52 | 9.8 |
- | 25 | 196 x 0.40 | 1.52 | 10.4 |
2 | 35 | 259 x 0.40 | 2.04 | 11.7 |
1 | - | 342 x 0.40 | 2.04 | 13.6 |
- | 50 | 370 x 0.40 | 2.04 | 14.3 |
1/0 | - | 425 x 0.40 | 2.04 | 15.0 |
2/0 | 70 | 340 x 0.50 | 2.04 | 16.5 |
3/0 | - | 434 x 0.50 | 2.04 | 17.7 |
- | 95 | 475 x 0.50 | 2.04 | 18.7 |
4/0 | - | 546 x 0.50 | 2.04 | 19.6 |
conducting metal | BCDEFG |
KEY
Conducting metal
B Tin-plated copper
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified