trebuie să fii logat
Category
Fotografiile au doar scop informativ. Vizualizați specificațiile produsului
please use latin characters
Functions DS402 standard modes Electronic gearing, camming, stepper emulation Analog speed drive, stand-alone positioner Safety Safe Torque Off (STO) function SIL 3 Motion safety functions SIL 2: SS1 / SS2 / SOS / SLS / SDI / SBC Power ranges 230 VAC: 5 to 17 Arms max. 480 VAC: 8 to 200 Arms max. Interfaces RS-232, CANopen®, EtherCAT® Digital and analog I/Os Sensors Encoders: incremental, Hiperface® absolute, SinCos, HES Digital encoder: Hiperface DSL® (one single motor cable) Tools Gem Drive Studio: drive configuration software Safety Tool: safety functions configuration software |
Drive type |
PAC-SF01-230 |
PAC-SF01-400 |
PAC-SF01-400 |
|
Power supply type |
GDPS-4003 |
|||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
/05 |
/11 |
/17 |
/08 |
/20 |
/45 |
/100 |
/200 |
|
/16 |
/32 |
/64 |
|
Peak current [Arms] |
5 |
11 |
17 |
8 |
20 |
45 |
100 |
200 |
Nominal power |
16kW |
32kW |
64kW |
|
Cont. current [Arms] |
2,5 |
5,5 |
8,5 |
4 |
10 |
22,5 |
35 |
75 |
Voltage |
3x230VAC / 3x480VAC |
|||
Voltage |
1x230VAC1/320 VDC2 |
3x480VAC1/680 VDC2 |
680VDC2 |
3Integrated mains filter, DC bus output for parallel connection of several drives, external braking resistor |
1 Integrated power supply2External power supply
Certifications |
Safety |
|
---|---|---|
|
Safe Torque Off SIL 3 STO safety function integrated in the drive | |
Safety standards |
Advanced safety functions SIL 2 | |
|
|
|
The monitoring of motor movements by means of the safety functions allows the live machine to be stopped (Safe stop) without having to go through a process of restarting and resetting the machine. This functionality greatly enhances productivity and saves time.
Safety system overview |
Safety Tool |
![]() |
![]() |
Parameter setting assistent of the safety functions |
Dimensions [mm] |
A |
B |
C |
D |
E* |
X |
Y |
---|---|---|---|---|---|---|---|
Pac-SF01-230 V / 5 - 17 A |
178 |
148 |
178 |
70 |
- |
169 |
80 |
Pac- SF01-400 V / 8 - 45 A |
221 |
203 |
235 |
70(80*) |
125 |
225 |
80 |
Pac- SF01-400 V / 100 A |
244 |
203 |
235 |
80(80*) |
125 |
225 |
80 |
Pac- SF01-400 V / 200 A |
215 |
265 |
295 |
166,6 |
- |
285 |
100 |
GDPS-400 V / 16/32 kW |
158 |
203 |
235 |
70 |
- |
225 |
80 |
GDPS-400 V / 64 kW |
207 |
262,5 |
295 |
71,5 |
- |
285 |
80 |
Sunteți interesat de acest produs? Aveți nevoie de informații suplimentare sau de prețuri individuale?
trebuie să fii logat
Functions DS402 standard modes Electronic gearing, camming, stepper emulation Analog speed drive, stand-alone positioner Safety Safe Torque Off (STO) function SIL 3 Motion safety functions SIL 2: SS1 / SS2 / SOS / SLS / SDI / SBC Power ranges 230 VAC: 5 to 17 Arms max. 480 VAC: 8 to 200 Arms max. Interfaces RS-232, CANopen®, EtherCAT® Digital and analog I/Os Sensors Encoders: incremental, Hiperface® absolute, SinCos, HES Digital encoder: Hiperface DSL® (one single motor cable) Tools Gem Drive Studio: drive configuration software Safety Tool: safety functions configuration software |
Drive type |
PAC-SF01-230 |
PAC-SF01-400 |
PAC-SF01-400 |
|
Power supply type |
GDPS-4003 |
|||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
/05 |
/11 |
/17 |
/08 |
/20 |
/45 |
/100 |
/200 |
|
/16 |
/32 |
/64 |
|
Peak current [Arms] |
5 |
11 |
17 |
8 |
20 |
45 |
100 |
200 |
Nominal power |
16kW |
32kW |
64kW |
|
Cont. current [Arms] |
2,5 |
5,5 |
8,5 |
4 |
10 |
22,5 |
35 |
75 |
Voltage |
3x230VAC / 3x480VAC |
|||
Voltage |
1x230VAC1/320 VDC2 |
3x480VAC1/680 VDC2 |
680VDC2 |
3Integrated mains filter, DC bus output for parallel connection of several drives, external braking resistor |
1 Integrated power supply2External power supply
Certifications |
Safety |
|
---|---|---|
|
Safe Torque Off SIL 3 STO safety function integrated in the drive | |
Safety standards |
Advanced safety functions SIL 2 | |
|
|
|
The monitoring of motor movements by means of the safety functions allows the live machine to be stopped (Safe stop) without having to go through a process of restarting and resetting the machine. This functionality greatly enhances productivity and saves time.
Safety system overview |
Safety Tool |
![]() |
![]() |
Parameter setting assistent of the safety functions |
Dimensions [mm] |
A |
B |
C |
D |
E* |
X |
Y |
---|---|---|---|---|---|---|---|
Pac-SF01-230 V / 5 - 17 A |
178 |
148 |
178 |
70 |
- |
169 |
80 |
Pac- SF01-400 V / 8 - 45 A |
221 |
203 |
235 |
70(80*) |
125 |
225 |
80 |
Pac- SF01-400 V / 100 A |
244 |
203 |
235 |
80(80*) |
125 |
225 |
80 |
Pac- SF01-400 V / 200 A |
215 |
265 |
295 |
166,6 |
- |
285 |
100 |
GDPS-400 V / 16/32 kW |
158 |
203 |
235 |
70 |
- |
225 |
80 |
GDPS-400 V / 64 kW |
207 |
262,5 |
295 |
71,5 |
- |
285 |
80 |
Aprecierea ta pentru recenzie nu a putut fi trimisa