![Thermal Relay PTC MS220KA Тип Thermal Relay PTC MS220KA Тип](https://www.dacpol.eu/7839-large_default/ptc-relay-msf220k.jpg)
![Thermal Relay PTC MS220KA Тип Thermal Relay PTC MS220KA Тип](https://www.dacpol.eu/7839-large_default/ptc-relay-msf220k.jpg)
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографии предназначены только для информационных целей. Посмотреть спецификацию продукта
please use latin characters
PTC-relay for the monitoring of dry transformers. Alarm 1 with relay in closedcircuit current mode for preliminary warning, releases at over-temperature at PTC-set 1 and serves at the same time as functional monitoring. Alarm 2 in operating current mode. Thus no wiping signal occurs when switching on the supply voltage on. Additional terminals enable comfortable wiring from supply voltage to relays K1 and/or K2. Changes from T221715/T221716 to T221717/T221718 (cURus, monitoring of sensors activatable, improved test function)
Part number:
|
Rated supply voltage Us | AC 220 - 240 V ± 10%, 50/60 Hz, ≤ 2 VA AC / DC 24 - 240 V, AC 19 - 264 V, DC 20 - 297 V <3 VA |
---|---|
Connectable PTC resistors | 2 x 1 ... 6 PTC according to DIN VDE V 0898-1-401 (formerly DIN 44081/82) |
Switching point | <4000 Ω |
Output relay | 1 change-over-contact (co), 1 normally-open contact (no) |
Type of contact | Type 2 (see general technical information) |
Test conditions | see general technical information |
Rated ambient temperature | -20 ... + 55 ° C |
Dimensions h x w x d | Design K: 75 x 22.5 x 115 [mm] |
Attachment | on 35 mm DIN rail according to EN 60 715 or screws M4 (option) |
Protection Housing/Terminals | IP30 / IP20 |
Weight | approx. 110 g |
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
PTC-relay for the monitoring of dry transformers. Alarm 1 with relay in closedcircuit current mode for preliminary warning, releases at over-temperature at PTC-set 1 and serves at the same time as functional monitoring. Alarm 2 in operating current mode. Thus no wiping signal occurs when switching on the supply voltage on. Additional terminals enable comfortable wiring from supply voltage to relays K1 and/or K2. Changes from T221715/T221716 to T221717/T221718 (cURus, monitoring of sensors activatable, improved test function)
Part number:
|
Rated supply voltage Us | AC 220 - 240 V ± 10%, 50/60 Hz, ≤ 2 VA AC / DC 24 - 240 V, AC 19 - 264 V, DC 20 - 297 V <3 VA |
---|---|
Connectable PTC resistors | 2 x 1 ... 6 PTC according to DIN VDE V 0898-1-401 (formerly DIN 44081/82) |
Switching point | <4000 Ω |
Output relay | 1 change-over-contact (co), 1 normally-open contact (no) |
Type of contact | Type 2 (see general technical information) |
Test conditions | see general technical information |
Rated ambient temperature | -20 ... + 55 ° C |
Dimensions h x w x d | Design K: 75 x 22.5 x 115 [mm] |
Attachment | on 35 mm DIN rail according to EN 60 715 or screws M4 (option) |
Protection Housing/Terminals | IP30 / IP20 |
Weight | approx. 110 g |
Не удаётся отправить вашу оценку отзыва
Пожаловаться на комментарий
Жалоба отправлена
Не удаётся отправить вашу жалобу
Оставьте свой отзыв
Отзыв отправлен
Не удаётся отправить отзыв