Display | backlit LCD |
---|---|
Max. indication | digits (9999) |
Decimal point position | automatic |
Adjustable backlight | 5 levels |
Readings update | < 0,5 sec. |
Measuring type | TRMS |
Basic accuracy | ±0,5% |
Nominal input voltage Un | 400V |
Nominal input current In | 1-5A; 63A; 125A |
Input range(1) | 10-120% Un, 5-120% In |
Operating frequency | 45...65Hz |
CT ratio (max. primary) | 15000A |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Power supply | 230V (45...65Hz) ±10% |
Power consumption | 6VA |
Operating temperature | 0...+23...+50°C |
Storage temperature | -30...+70°C |
Self estinguishing | |
Thermoplastic material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | alim./ ingressi aux. supply/inputs |
Test voltage | 2kV, 50Hz, 60sec. |
Multifunction meter, suitable for three-phase three or four wires systems unbalanced load, even with distorted wave-forms. It displays of the main electrical measurements of an electrical network, including active and reactive energy coun-ting. Two versions with direct current input 63 and 125A supplied with triple miniature CTs have been introduced, alongside the version with the CT input, to reduce cost and wiring time. Thanks to its small size and compatibility with spacings of modular switches, the miniature CTs can be mounted in a very small spaces conditions, both upstream and downstream of the 'switch as shown in the pictures.
![]() |
![]() |
TYPE | Description | CODE |
---|---|---|
NANO5 | Three-phase 3 or 4 wires input 1-5A from CT |
Q52P3L005X4C2 |
NANO63 | Three-phase 3 or 4 wires provided withtriple CT 63A |
Q52D3L063X4C2 |
NANO125 | Three-phase 3 or 4 wires provided withtriple CT 125A |
Q52D3L125X4C2 |
Mierzone wartości:
The 4 front buttons allow immediate display of the measure concerned, without scrolling all display values. The display measurement sequence is indicated on each button. the pictures on the left side show the display values sequence after each button click. Thank to the display digits size and to five backlight setting the meter is easly readable even to a high distance.
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
Display | backlit LCD |
---|---|
Max. indication | digits (9999) |
Decimal point position | automatic |
Adjustable backlight | 5 levels |
Readings update | < 0,5 sec. |
Measuring type | TRMS |
Basic accuracy | ±0,5% |
Nominal input voltage Un | 400V |
Nominal input current In | 1-5A; 63A; 125A |
Input range(1) | 10-120% Un, 5-120% In |
Operating frequency | 45...65Hz |
CT ratio (max. primary) | 15000A |
Continuous overload | 2 x In; 1.2 x Un |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption | < 0.5VA |
Voltage circuits consumption | < 0.5VA |
Power supply | 230V (45...65Hz) ±10% |
Power consumption | 6VA |
Operating temperature | 0...+23...+50°C |
Storage temperature | -30...+70°C |
Self estinguishing | |
Thermoplastic material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | alim./ ingressi aux. supply/inputs |
Test voltage | 2kV, 50Hz, 60sec. |
Multifunction meter, suitable for three-phase three or four wires systems unbalanced load, even with distorted wave-forms. It displays of the main electrical measurements of an electrical network, including active and reactive energy coun-ting. Two versions with direct current input 63 and 125A supplied with triple miniature CTs have been introduced, alongside the version with the CT input, to reduce cost and wiring time. Thanks to its small size and compatibility with spacings of modular switches, the miniature CTs can be mounted in a very small spaces conditions, both upstream and downstream of the 'switch as shown in the pictures.
![]() |
![]() |
TYPE | Description | CODE |
---|---|---|
NANO5 | Three-phase 3 or 4 wires input 1-5A from CT |
Q52P3L005X4C2 |
NANO63 | Three-phase 3 or 4 wires provided withtriple CT 63A |
Q52D3L063X4C2 |
NANO125 | Three-phase 3 or 4 wires provided withtriple CT 125A |
Q52D3L125X4C2 |
Mierzone wartości:
The 4 front buttons allow immediate display of the measure concerned, without scrolling all display values. The display measurement sequence is indicated on each button. the pictures on the left side show the display values sequence after each button click. Thank to the display digits size and to five backlight setting the meter is easly readable even to a high distance.