The efficient solution for your explosion-protected lighting concept
The explosion-protected linear light fittings series eLLK/M 92 LED 400A/800A combines the latest LED technology with the protection of a reliable housing solution. As a result, this light fitting series is the ideal solution for lighting tasks in harsh and hazardous environments.
Latest lighting technology for a proven lighting concept
As a leading manufacturer of explosion- protected luminaires, we have redesigned our revolutionary LED module to fit into the eLLK/M... linear light fitting series.
With the new Gen2 modules, our LED linear luminaires are even more efficient and brighter than before. In addition, they now also have an extended temperature range from -25 °C to +55 °C. The new eLLK-2/4-C/W LED module can also be used for converting existing eLLK/M 92 light fittings with fluorescent lamps and an electronic ballast (EVG 09) into LED linear light fittings in just few simple steps.
The LED system design and certification allow the use in the proved Ex e technology of the eLLK/M 92 light fittings. With the use of our electronic ballast EVG 09 as the driver, we can rely on more than 20 years successful and safe operation in harsh and hazardous environments.
The advantages of the LED module:
Energy and cost savings
Operating life
Easy and cost-effective installation
Like all the luminaires in the eLLK lighting family, our standard LED linear luminaires feature a single-ended throughwiring, which, in conjunction with the generously dimensioned terminal compartment,
allows a cost-effective installation. The double-sided locking facility with 10 or 20 latch points
allows the protective bowl to be hinged on both sides, meaning that the fitting can be mounted
on either side.
Features
eLLK 92 LED 400A/800A
eLLK/M 92 LED 400A | eLLK/M 92 LED 800A | |
---|---|---|
EC-Type Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking accd. to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking accd. to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +55 °C | -25 °C up to +55 °C |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Rated voltage | 110 V - 254 V AC 110 V - 250 V DC |
110 V - 254 V AC 110 V - 250 V DC |
Power consumtion | 29 W | 57 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Life expectancy LED module | L 70 = 110.000 h at ta=25 °C | L 70 = 110.000 h at ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG | EVG |
Protection class | I | I |
Immunity to surge voltages according to EN 61000-4-5 | 4 kV, L - N oraz L - PE | 4 kV, L - N oraz L - PE |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) |
2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Dimensions (L x W x H) | 760 x 188 x 130 [mm] (eLLK) 1060 x 188 x 130 [mm] (eLLM) |
1360 x 188 x 130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 7.2 kg (eLLK)/9.2 kg (eLLM) | 11.1 kg (eLLK)/13.1 kg (eLLM) |
Cable glands/gland plates/enclosure drilling | Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Degree of protection accd. to EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonat | Polycarbonat |
eLLK 92 LED 400A V-CG-S / eLLK 92 LED 800A V-CG-S
eLLK 92 LED 400A V-CG-S | eLLK 92 LED 800A V-CG-S | |
---|---|---|
EC-Tye Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +50 °C | -25 °C up to +50 °C |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Rated voltage | 220 - 254 V AC 195 - 250 V DC |
220 - 254 V AC 195 - 250 V DC |
Power consumtion | 29 W | 57 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Lifetime LED module | L 70 = 110 000 h przy ta=25 °C | L 70 = 110 000 h przy ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG/V-CG-S | EVG/V-CG-S |
Insulation class | I | I |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) | 2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Rated luminous flux in emergency operation of the luminaire (one LED-row) | 1350 lm (5700 k)/1282 lm (4000 K) | 2675 lm (5700 k)/2542 lm (4000 K) |
Rated emergency operating time | - | - |
Dimensions (L x W x H) | 760 x 188 x 130 [mm] | 1360 x 188 x 130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 7.6 kg | 11.5 kg |
Cable glands/Gland plates/Enclosure drilling | Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Degree of protection accd. EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonat | Polycarbonat |
1) with dustcover if entry/thread is not closed
eLLK/M 92 LED 400A NE / eLLK 92 LED 800A NE
eLLK/M 92 LED 400A NE | eLLK 92 LED 800A NE | |
---|---|---|
EC-Tye Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +55 °C (specified data: -5 °C up to +35 °C) |
-25 °C up to +55 °C (specified data: -5 °C up to +35 °C) |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Battery | Battery set with 7 Ah-NC battery, with LED display and monitoring via microprocessor |
Battery set with 7 Ah-NC battery, with LED display and monitoring via microprocessor |
Rated voltage | 120 - 254 V AC | 120 - 254 V AC |
Power consumtion | 34 W | 62 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Charging duration | ≥ 14h | ≥ 14h |
Lifetime LED module | L 70 = 110 000 h przy ta=25 °C | L 70 = 110 000 h przy ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG with emergency lighting supply | EVG with emergency lighting supply |
Insulation class | I | I |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) | 2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Rated luminous flux in emergency operation of the luminaire (one LED-row) | 1282 lm (5700 k)/1217 lm (4000 K) | 1739 lm (5700 k)/1653 lm (4000 K) |
Rated emergency operating time | 877 lm (5700 k) / 834 lm (4000 K) | 1204 lm (5700 k) / 1144 lm (4000 K) |
Luminous flux relation normal/ emergency opration (one LED line) | 1,5 h or 3 h, adjustable on site | 1,5 h or 3 h, adjustable on site |
luminous flux ratio in emergency mode (one LED line) | 95 % (1,5 h) - 65 % (3 h) | 65 % (1,5 h) - 45 % (3 h) |
Dimensions (L x W x H) | 900x188x130/1500x188x 30 [mm] | 900x188x130/1500x188x130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 10.3 kg | 14.4 kg |
Cable glands/Gland plates/Enclosure drilling | Ex-e-cable glands M25 x 1,5 (plastic), option: M20 x 1,5 metal thread 1) |
Ex-e-cable glands M25 x 1,5 (plastic), option: M20 x 1,5 metal thread 1) |
Degree of protection accd. EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonate | Polycarbonate |
1) with dustcover if entry/thread is not closed
Accessories
Type | Order No for 4000 K | Order No for 5700 K | |
---|---|---|---|
eLLK-2 | LED module for eLLK/M 92 018/18 incl. conversion kit for standard fluorescent light fittings | CCL 1635 129 | CCL 1635 127 |
eLLK-4 | LED module for eLLK/M 92 036/36 incl. conversion kit for standard fluorescent light fittings | CCL 1635 130 | CCL 1635 128 |
eLLK-2 | LED module for eLLK/M 92 018/18 LED Ready / eLLK 92 LED 400A | CCL 1634 699 | CCL 1634 697 |
eLLK-4 | LED module for eLLK/M 92 036/36 LED Ready / eLLK 92 LED 800A | CCL 1634 700 | CCL 1634 698 |
Type | Order No | ||
Single sided through wiring 2/6 with 2 entries M25, incl. terminals and mounting material | 2 2218 602 000 | ||
Battery set Type 2710-12 with LED display for eLL..92..NE | 2 2710 906 000 | ||
Single sided through wiring 2/6 with 2 entries M25, incl. terminals and mounting material for eLLM 92 LED 400A/800A | 2 2218 602 000 | ||
Protective bowl with green filter for eye wash safety shower facilities (eLLK 92 LED 400A) | 2 2215 402 018 |
Polar curve / Dimension drawing
![]() Polar curve eLLK/M 92 LED 400A/800A |
![]() Polar curve eLLK/M 92 LED 400A/800A NE in emergency mode |
Dimensions
![]() |
Ordering details – eLLK/M 92 LED 400A/800A
Version | Terminals | Through-wiring | Cable gland/thread | Threaded plug | Blanking plug | Order No for 4000 K | Order No for 5700 K | |
---|---|---|---|---|---|---|---|---|
single-ended | twin-ended | |||||||
eLLK 92 LED 400A | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2265 505 101 | 1 2265 504 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2265 505 103 | 1 2265 504 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2265 505 109 | 1 2265 504 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2265 505 111 | 1 2265 504 111 | |
eLLK 92 LED 800A | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2266 505 101 | 1 2266 504 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2266 505 103 | 1 2266 504 103 | |
1/6-1M1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2266 505 109 | 1 2266 504 109 | |
2/6-2M1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2266 505 111 | 1 2266 504 111 | |
eLLM 92 LED 400A/800A | ||||||||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2268 505 101 | 1 2268 504 101 | ||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2269 505 101 | 1 2269 504 101 | ||
eLLK 92 LED 400A V-CG-S 2) | ||||||||
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2265 517 103 | 1 2265 516 103 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M25 | 1 2265 517 111 | 1 2265 516 111 | |
eLLK 92 LED 800A V-CG-S 2) | ||||||||
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2266 517 103 | 1 2266 516 103 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M25 | 1 2266 517 111 | 1 2266 516 111 | |
eLLK 92 LED 400A NE 3) | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2260 588 101 | 1 2260 587 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2260 588 103 | 1 2260 587 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2260 588 109 | 1 2260 587 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2260 588 111 | 1 2260 587 111 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M25, Metal thread | 2 x M25 | 1 2260 588 609 | 1 2260 587 609 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M25, Metal thread | 4 x M25 | 1 2260 588 611 | 1 2260 587 611 | |
eLLK 92 LED 800A NE 3) | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2261 588 101 | 1 2261 587 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2261 588 103 | 1 2261 587 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2261 588 109 | 1 2261 587 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2261 588 111 | 1 2261 587 111 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M25, Metal thread | 2 x M25 | 1 2261 588 609 | 1 2261 587 609 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M25, Metal thread | 4 x M25 | 1 2261 588 611 | 1 2261 587 611 | |
eLLM 92 LED 400A NE 3) | ||||||||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2273 588 101 | 1 2273 587 101 |
Scope of delivery including LED-module, without fixing material. Metal cable glands see catalogue part 2: 2.3.12 ff
1) with metal thread, without cable gland / 2) for operation with CEAG-emergency supply system / 3) self-contained emergency light fittingВы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The efficient solution for your explosion-protected lighting concept
The explosion-protected linear light fittings series eLLK/M 92 LED 400A/800A combines the latest LED technology with the protection of a reliable housing solution. As a result, this light fitting series is the ideal solution for lighting tasks in harsh and hazardous environments.
Latest lighting technology for a proven lighting concept
As a leading manufacturer of explosion- protected luminaires, we have redesigned our revolutionary LED module to fit into the eLLK/M... linear light fitting series.
With the new Gen2 modules, our LED linear luminaires are even more efficient and brighter than before. In addition, they now also have an extended temperature range from -25 °C to +55 °C. The new eLLK-2/4-C/W LED module can also be used for converting existing eLLK/M 92 light fittings with fluorescent lamps and an electronic ballast (EVG 09) into LED linear light fittings in just few simple steps.
The LED system design and certification allow the use in the proved Ex e technology of the eLLK/M 92 light fittings. With the use of our electronic ballast EVG 09 as the driver, we can rely on more than 20 years successful and safe operation in harsh and hazardous environments.
The advantages of the LED module:
Energy and cost savings
Operating life
Easy and cost-effective installation
Like all the luminaires in the eLLK lighting family, our standard LED linear luminaires feature a single-ended throughwiring, which, in conjunction with the generously dimensioned terminal compartment,
allows a cost-effective installation. The double-sided locking facility with 10 or 20 latch points
allows the protective bowl to be hinged on both sides, meaning that the fitting can be mounted
on either side.
Features
eLLK 92 LED 400A/800A
eLLK/M 92 LED 400A | eLLK/M 92 LED 800A | |
---|---|---|
EC-Type Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking accd. to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking accd. to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +55 °C | -25 °C up to +55 °C |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Rated voltage | 110 V - 254 V AC 110 V - 250 V DC |
110 V - 254 V AC 110 V - 250 V DC |
Power consumtion | 29 W | 57 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Life expectancy LED module | L 70 = 110.000 h at ta=25 °C | L 70 = 110.000 h at ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG | EVG |
Protection class | I | I |
Immunity to surge voltages according to EN 61000-4-5 | 4 kV, L - N oraz L - PE | 4 kV, L - N oraz L - PE |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) |
2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Dimensions (L x W x H) | 760 x 188 x 130 [mm] (eLLK) 1060 x 188 x 130 [mm] (eLLM) |
1360 x 188 x 130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 7.2 kg (eLLK)/9.2 kg (eLLM) | 11.1 kg (eLLK)/13.1 kg (eLLM) |
Cable glands/gland plates/enclosure drilling | Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Degree of protection accd. to EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonat | Polycarbonat |
eLLK 92 LED 400A V-CG-S / eLLK 92 LED 800A V-CG-S
eLLK 92 LED 400A V-CG-S | eLLK 92 LED 800A V-CG-S | |
---|---|---|
EC-Tye Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +50 °C | -25 °C up to +50 °C |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Rated voltage | 220 - 254 V AC 195 - 250 V DC |
220 - 254 V AC 195 - 250 V DC |
Power consumtion | 29 W | 57 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Lifetime LED module | L 70 = 110 000 h przy ta=25 °C | L 70 = 110 000 h przy ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG/V-CG-S | EVG/V-CG-S |
Insulation class | I | I |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) | 2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Rated luminous flux in emergency operation of the luminaire (one LED-row) | 1350 lm (5700 k)/1282 lm (4000 K) | 2675 lm (5700 k)/2542 lm (4000 K) |
Rated emergency operating time | - | - |
Dimensions (L x W x H) | 760 x 188 x 130 [mm] | 1360 x 188 x 130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 7.6 kg | 11.5 kg |
Cable glands/Gland plates/Enclosure drilling | Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Ex-e cable glands M25 x 1.5 (plastic), option: M20/M25 x 1.5 metal thread1) |
Degree of protection accd. EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonat | Polycarbonat |
1) with dustcover if entry/thread is not closed
eLLK/M 92 LED 400A NE / eLLK 92 LED 800A NE
eLLK/M 92 LED 400A NE | eLLK 92 LED 800A NE | |
---|---|---|
EC-Tye Examination Certificate | BVS 09 ATEX E 034 | BVS 09 ATEX E 034 |
IECEx Certificate of Conformity | IECEx BVS 09.0033 | IECEx BVS 09.0033 |
Marking to 2014/34/EU | II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
II 2 G Ex db eb mb op is IIC T4 Gb II 2 D Ex tb IIIC T80 °C Db IP66 |
Marking to IECEx | Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Ex db eb mb op is IIC T4 Gb Ex tb IIIC T80 °C Db |
Permissible ambient temperature | -25 °C up to +55 °C (specified data: -5 °C up to +35 °C) |
-25 °C up to +55 °C (specified data: -5 °C up to +35 °C) |
IK-class according to IEC/EN 62262 | IK 10 ≙ 20 J | IK 10 ≙ 20 J |
Battery | Battery set with 7 Ah-NC battery, with LED display and monitoring via microprocessor |
Battery set with 7 Ah-NC battery, with LED display and monitoring via microprocessor |
Rated voltage | 120 - 254 V AC | 120 - 254 V AC |
Power consumtion | 34 W | 62 W |
Frequency | 50 – 60 Hz | 50 – 60 Hz |
Charging duration | ≥ 14h | ≥ 14h |
Lifetime LED module | L 70 = 110 000 h przy ta=25 °C | L 70 = 110 000 h przy ta=25 °C |
Power factor cos ϕ | ≥ 0.95 | ≥ 0.95 |
Circuit | EVG with emergency lighting supply | EVG with emergency lighting supply |
Insulation class | I | I |
Illuminance at measurement plane | comparable with luminaires for fluorescent lamps | comparable with luminaires for fluorescent lamps |
CRI | > 80 | > 80 |
Lamp/Illuminant | eLLK-2-C - 2 x 13 W | eLLK-2-C - 2 x 26 W |
Light colour | 5700 K (4000 K on request) | 5700 K (4000 K on request) |
Rated luminous flux of the luminaire (typical, ± 10 %) | 2700 lm (5700 K)/2565 lm (4000 K) | 5350 lm (5700 K)/5085 lm (4000 K) |
Rated luminous flux in emergency operation of the luminaire (one LED-row) | 1282 lm (5700 k)/1217 lm (4000 K) | 1739 lm (5700 k)/1653 lm (4000 K) |
Rated emergency operating time | 877 lm (5700 k) / 834 lm (4000 K) | 1204 lm (5700 k) / 1144 lm (4000 K) |
Luminous flux relation normal/ emergency opration (one LED line) | 1,5 h or 3 h, adjustable on site | 1,5 h or 3 h, adjustable on site |
luminous flux ratio in emergency mode (one LED line) | 95 % (1,5 h) - 65 % (3 h) | 65 % (1,5 h) - 45 % (3 h) |
Dimensions (L x W x H) | 900x188x130/1500x188x 30 [mm] | 900x188x130/1500x188x130 [mm] |
Connecting terminals | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal | L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal |
Enclosure colour | RAL 7035 light grey | RAL 7035 light grey |
Enclosure material | Glass-fibre reinforced polyester | Glass-fibre reinforced polyester |
Weight | 10.3 kg | 14.4 kg |
Cable glands/Gland plates/Enclosure drilling | Ex-e-cable glands M25 x 1,5 (plastic), option: M20 x 1,5 metal thread 1) |
Ex-e-cable glands M25 x 1,5 (plastic), option: M20 x 1,5 metal thread 1) |
Degree of protection accd. EN 60529 | IP66/IP67 | IP66/IP67 |
Protective cover/protective bowl | Polycarbonate | Polycarbonate |
1) with dustcover if entry/thread is not closed
Accessories
Type | Order No for 4000 K | Order No for 5700 K | |
---|---|---|---|
eLLK-2 | LED module for eLLK/M 92 018/18 incl. conversion kit for standard fluorescent light fittings | CCL 1635 129 | CCL 1635 127 |
eLLK-4 | LED module for eLLK/M 92 036/36 incl. conversion kit for standard fluorescent light fittings | CCL 1635 130 | CCL 1635 128 |
eLLK-2 | LED module for eLLK/M 92 018/18 LED Ready / eLLK 92 LED 400A | CCL 1634 699 | CCL 1634 697 |
eLLK-4 | LED module for eLLK/M 92 036/36 LED Ready / eLLK 92 LED 800A | CCL 1634 700 | CCL 1634 698 |
Type | Order No | ||
Single sided through wiring 2/6 with 2 entries M25, incl. terminals and mounting material | 2 2218 602 000 | ||
Battery set Type 2710-12 with LED display for eLL..92..NE | 2 2710 906 000 | ||
Single sided through wiring 2/6 with 2 entries M25, incl. terminals and mounting material for eLLM 92 LED 400A/800A | 2 2218 602 000 | ||
Protective bowl with green filter for eye wash safety shower facilities (eLLK 92 LED 400A) | 2 2215 402 018 |
Polar curve / Dimension drawing
![]() Polar curve eLLK/M 92 LED 400A/800A |
![]() Polar curve eLLK/M 92 LED 400A/800A NE in emergency mode |
Dimensions
![]() |
Ordering details – eLLK/M 92 LED 400A/800A
Version | Terminals | Through-wiring | Cable gland/thread | Threaded plug | Blanking plug | Order No for 4000 K | Order No for 5700 K | |
---|---|---|---|---|---|---|---|---|
single-ended | twin-ended | |||||||
eLLK 92 LED 400A | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2265 505 101 | 1 2265 504 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2265 505 103 | 1 2265 504 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2265 505 109 | 1 2265 504 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2265 505 111 | 1 2265 504 111 | |
eLLK 92 LED 800A | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2266 505 101 | 1 2266 504 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2266 505 103 | 1 2266 504 103 | |
1/6-1M1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2266 505 109 | 1 2266 504 109 | |
2/6-2M1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2266 505 111 | 1 2266 504 111 | |
eLLM 92 LED 400A/800A | ||||||||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2268 505 101 | 1 2268 504 101 | ||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2269 505 101 | 1 2269 504 101 | ||
eLLK 92 LED 400A V-CG-S 2) | ||||||||
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2265 517 103 | 1 2265 516 103 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M25 | 1 2265 517 111 | 1 2265 516 111 | |
eLLK 92 LED 800A V-CG-S 2) | ||||||||
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2266 517 103 | 1 2266 516 103 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M25 | 1 2266 517 111 | 1 2266 516 111 | |
eLLK 92 LED 400A NE 3) | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2260 588 101 | 1 2260 587 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2260 588 103 | 1 2260 587 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2260 588 109 | 1 2260 587 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2260 588 111 | 1 2260 587 111 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M25, Metal thread | 2 x M25 | 1 2260 588 609 | 1 2260 587 609 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M25, Metal thread | 4 x M25 | 1 2260 588 611 | 1 2260 587 611 | |
eLLK 92 LED 800A NE 3) | ||||||||
1/6-1K | 1 x 6 | X | - | 2 x M25, Plastic | 1 | 1 2261 588 101 | 1 2261 587 101 | |
2/6-2K | 2 x 6 | - | X | 2 x M25, Plastic | 2 x M25 | 1 2261 588 103 | 1 2261 587 103 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M20, Metal thread | 1 x M20 | 1 2261 588 109 | 1 2261 587 109 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M20, Metal thread | 2 x M20 | 1 2261 588 111 | 1 2261 587 111 | |
1/6-1M 1) | 1 x 6 | X | - | 2 x M25, Metal thread | 2 x M25 | 1 2261 588 609 | 1 2261 587 609 | |
2/6-2M 1) | 2 x 6 | - | X | 4 x M25, Metal thread | 4 x M25 | 1 2261 588 611 | 1 2261 587 611 | |
eLLM 92 LED 400A NE 3) | ||||||||
1/3-1K | 1 x 3 | - | - | 1 x M25, Plastic | 1 2273 588 101 | 1 2273 587 101 |
Scope of delivery including LED-module, without fixing material. Metal cable glands see catalogue part 2: 2.3.12 ff
1) with metal thread, without cable gland / 2) for operation with CEAG-emergency supply system / 3) self-contained emergency light fittingНе удаётся отправить вашу оценку отзыва