NON-INVASIVE CURRENT MEASUREMENT | |||
---|---|---|---|
MODEL |
CP 5_10 |
CP 50_10 |
CP 150_10 |
Current Range | 5A DC or AC RMS | 50A DC or AC RMS | 150A DC or AC PEAK |
Output Sensitivity | 100mV/A | 100mV/A | 50mV/A |
Frequency Range | DC to 100kHz (-1dB) | ||
Resolution | ± 1mA | ||
Basic Accuracy | ± 1% of reading ± 2mA | ||
Output connection | 2.9m cable unterminated |
ENVIRONMENTAL DATA
|
|
Operating Temperature
|
0°C to 50°C
|
Temperature Coefficient
|
± 0.15% of reading peroC |
Storage Temperature (without battery)
|
-20°C to 85°C
|
POWER SUPPLY
|
|
External Power
|
± 10.5 to ±16V
|
MECHANICAL DATA
|
|
Dimensions (mm)
|
194 (W) x 74 (S) x 25 (G)
|
Jaw Capacity |
25mm Ø |
Weight
|
320 g
|
SAFETY
|
|
EN61010-2-032:2002,
300V, Measurement Category III, Pollution Degree 2. |
|
Output limited to 30V to Earth (Unterminated)
|
|
MAXIMUM SAFE VOLTAGES
|
|
300V AC RMS or DC between uninsulated conductor and ground
|
|
EMC Standard EN 61326-2-2:2006
|
|
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F)
|
High Accuracy
Advanced patented magnetic circuit design results in accuracy to be little affected by external magnetic fields or off-centre conductor positioning.
EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference
Catalog number
|
---|
CP 5_10 |
CP 50_10 |
CP 150_10 |
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
NON-INVASIVE CURRENT MEASUREMENT | |||
---|---|---|---|
MODEL |
CP 5_10 |
CP 50_10 |
CP 150_10 |
Current Range | 5A DC or AC RMS | 50A DC or AC RMS | 150A DC or AC PEAK |
Output Sensitivity | 100mV/A | 100mV/A | 50mV/A |
Frequency Range | DC to 100kHz (-1dB) | ||
Resolution | ± 1mA | ||
Basic Accuracy | ± 1% of reading ± 2mA | ||
Output connection | 2.9m cable unterminated |
ENVIRONMENTAL DATA
|
|
Operating Temperature
|
0°C to 50°C
|
Temperature Coefficient
|
± 0.15% of reading peroC |
Storage Temperature (without battery)
|
-20°C to 85°C
|
POWER SUPPLY
|
|
External Power
|
± 10.5 to ±16V
|
MECHANICAL DATA
|
|
Dimensions (mm)
|
194 (W) x 74 (S) x 25 (G)
|
Jaw Capacity |
25mm Ø |
Weight
|
320 g
|
SAFETY
|
|
EN61010-2-032:2002,
300V, Measurement Category III, Pollution Degree 2. |
|
Output limited to 30V to Earth (Unterminated)
|
|
MAXIMUM SAFE VOLTAGES
|
|
300V AC RMS or DC between uninsulated conductor and ground
|
|
EMC Standard EN 61326-2-2:2006
|
|
All accuracies stated at 23°C ± 1°C (73.4°F ± 1.8°F)
|
High Accuracy
Advanced patented magnetic circuit design results in accuracy to be little affected by external magnetic fields or off-centre conductor positioning.
EN61010-2-032:2002 and EMC Conformance
Safety features including a tactile barrier and special jaw design provide the user with confidence when making measurements in hazardous voltage areas.
Conformance to EMC standards ensures high reliability through reduced susceptibility to electromagnetic interference
Catalog number
|
---|
CP 5_10 |
CP 50_10 |
CP 150_10 |