APPLICATION
The PA39 power meter is a mowing-coil meter with a built-in measuring transducer. It is destined to measure active or reactive power in a.c. power networks. The measured power is indicated by a magnetoelectric (moving-coil) measuring system.
These meters are delivered in following versions:
Measuring ranges acc. the series | 1; 1,2; 1,5; 2; 2,5; 3; 4; 5; 6; 8 or the decimal multiplication of one of these numbers |
Input voltage | 100/√3 (x/100/√3); 100 (x/100), 133, 230, 280, 400, 500, 690 V |
Input current | 1 A (X/1A) 5 A (X/5A) |
Active power factor | cosφ 0,5poj. i 0,5ind. |
Reactive power factor | sinφ 0,5poj.. i 0,5ind. |
Accuracy class | 1,5 |
- ambient temperature | 5...23...400C |
- on request, tropical execution | 5...35...550C |
- relative humidity | 25... 85% |
- frequency of the input quantities | acc. order (table 1) |
- working position | acc. order 5° (table 2) |
- external magnetic field | ≤400A/m |
Additional errors | acc. EN 60051-1 standard |
Power consumption: | |
- voltage circuit | ≤3 [VA] |
- current circuit | ≤0,25 [VA] |
Protection Grade acc. to EN60529: | |
Front protection grade: | |
IP 50 for PA39 meters | |
IP 65 for PA39 meters (on request): | |
IP20 terminal protection (with a terminal protection cover) | |
Electromagnetic compatibility: | |
- emission | acc. EN 61000-6-4 standard |
- immunity | acc. EN 61000-6-2 standard |
The meter fulfils CE mark requirements. | |
Safety requirements acc. EN 61010-1: | |
- installation category | III |
- level of pollution | 2 |
- working voltage in relation to the earth | 600 V a.c. |
Weight | 400g |
Accessories | 400 g |
Equipment | |
We deliver with the meter: | |
- screw holders (IP50 option) | 2 pcs |
- screw holders (IP65 option) | 4 pcs |
- terminal protection cover | 1 pc |
- user’s manual | 1 pc |
- guarantee certificate | 1 pc |
CHOICE OF MEASURING RANGE
1. Calculate the power from the formulas:
P = Un X In for single-phase networks
P = √3 X Un X In for three-phase networks
where::
Un - network rated voltage:
• for three-phase networks - phase-to-phase voltage,
• when connected through transformers-primary rated voltage.
In - rated current
• 5 A or 1 A,
• when connected through transformers-primary rated voltage.
2. Round the calculated power value to the nearest value from the given sequence of numbers for the measuring range.
3. Example of measuring range choice
Three-phase network; rated values of transformers: 15 000/100 V i 400/5 A
P = √3 ´ 15 000 V ´ 400 A = 10,39 MW (Mvar)
Selected measuring range: 10 MW (Mvar)
Fig.1. PA39 meter outline drawing.
One should prepare in the panel a hole at dimensions: 92+0.8 x 92+0.8 mm.
The thickness of the material of which the panel is made, cannot exceed 15 mm.
The meter is fixed in the panel by two screw holders situated on arbitrary opposite corners of the case.
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
APPLICATION
The PA39 power meter is a mowing-coil meter with a built-in measuring transducer. It is destined to measure active or reactive power in a.c. power networks. The measured power is indicated by a magnetoelectric (moving-coil) measuring system.
These meters are delivered in following versions:
Measuring ranges acc. the series | 1; 1,2; 1,5; 2; 2,5; 3; 4; 5; 6; 8 or the decimal multiplication of one of these numbers |
Input voltage | 100/√3 (x/100/√3); 100 (x/100), 133, 230, 280, 400, 500, 690 V |
Input current | 1 A (X/1A) 5 A (X/5A) |
Active power factor | cosφ 0,5poj. i 0,5ind. |
Reactive power factor | sinφ 0,5poj.. i 0,5ind. |
Accuracy class | 1,5 |
- ambient temperature | 5...23...400C |
- on request, tropical execution | 5...35...550C |
- relative humidity | 25... 85% |
- frequency of the input quantities | acc. order (table 1) |
- working position | acc. order 5° (table 2) |
- external magnetic field | ≤400A/m |
Additional errors | acc. EN 60051-1 standard |
Power consumption: | |
- voltage circuit | ≤3 [VA] |
- current circuit | ≤0,25 [VA] |
Protection Grade acc. to EN60529: | |
Front protection grade: | |
IP 50 for PA39 meters | |
IP 65 for PA39 meters (on request): | |
IP20 terminal protection (with a terminal protection cover) | |
Electromagnetic compatibility: | |
- emission | acc. EN 61000-6-4 standard |
- immunity | acc. EN 61000-6-2 standard |
The meter fulfils CE mark requirements. | |
Safety requirements acc. EN 61010-1: | |
- installation category | III |
- level of pollution | 2 |
- working voltage in relation to the earth | 600 V a.c. |
Weight | 400g |
Accessories | 400 g |
Equipment | |
We deliver with the meter: | |
- screw holders (IP50 option) | 2 pcs |
- screw holders (IP65 option) | 4 pcs |
- terminal protection cover | 1 pc |
- user’s manual | 1 pc |
- guarantee certificate | 1 pc |
CHOICE OF MEASURING RANGE
1. Calculate the power from the formulas:
P = Un X In for single-phase networks
P = √3 X Un X In for three-phase networks
where::
Un - network rated voltage:
• for three-phase networks - phase-to-phase voltage,
• when connected through transformers-primary rated voltage.
In - rated current
• 5 A or 1 A,
• when connected through transformers-primary rated voltage.
2. Round the calculated power value to the nearest value from the given sequence of numbers for the measuring range.
3. Example of measuring range choice
Three-phase network; rated values of transformers: 15 000/100 V i 400/5 A
P = √3 ´ 15 000 V ´ 400 A = 10,39 MW (Mvar)
Selected measuring range: 10 MW (Mvar)
Fig.1. PA39 meter outline drawing.
One should prepare in the panel a hole at dimensions: 92+0.8 x 92+0.8 mm.
The thickness of the material of which the panel is made, cannot exceed 15 mm.
The meter is fixed in the panel by two screw holders situated on arbitrary opposite corners of the case.