Bega Induction Heaters are designed to heat bearings, bushings, gear wheels, couplings or other metallic work pieces which form a closed electrical loop. This will facilitate mounting where an interference fit is required.
The heaters are designed to heat the work piece up to a maximum temperature of 240ºC (464ºF), with the exception of the 22 ELD series models where the temperature is limited to a maximum of 150ºC (302ºF) and special custom-designed heaters where the maximum temperature can be as high as 480ºC (896ºF).
The heater works in the same way as a transformer. The primary coil is the heater and the secondary coil is the work piece.
When the heater is switched on, a high voltage, low alternating current passes through the numerous windings of the primary coil. This induces a low voltage, high current in the work piece acting as the secondary coil. This high current results in the heating up of the work piece.
The current is only flowing in the work piece, hence it is only this which starts to heat up. The work piece is automatically demagnetised at the end of each heating cycle.
Dane techniczne
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Type BETEX |
22 ELD Portable |
24 RLD
|
22 ESD |
24 RSD TURBO |
38 ESD |
||
---|---|---|---|---|---|---|---|
Facility power | 3.6 kVA | 3.6 kVA | 3.6 kVA | 3.6 kVA | 8 kVA | ||
Voltage/Amp | 120V/15A 230V/16A |
120V/15A 230V/16A |
120V/15A 230V/16A |
120V15A 230V/16A |
400/500V 20A |
||
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | ||
Yokes, standard mm/ set 1 | 7,10,14,20,40 in box | 7,10,14,20,40 in heater |
14, 30, 60 | 14, 30, 60 | 30,70 | ||
Yokes, standard mm/ set 2 | 10, 14, 20, 30, 60 | 10, 14, 20, 30, 60 | 20,30,70 | ||||
Swivel arm | - | - | yes | yes | yes | ||
Max. weight ± kg | - bearings | 15 | 40 | 40 | 95 | 125 | |
- other parts | 10 | 25 | 25 | 50 | 75 | ||
Min. ID Ø: mm | 10 | 10/Ø100 | 15/Ø100 | 15/Ø120 | 30/Ø115 | ||
Max. OD :mm*A | 240 | 350 | 340/580 *1 | 520 | 480/720 *1 | ||
Max. width: mm *B | 120 | 135 | 150 | 200 | 200 | ||
Max. width *C at horizontal heating: mm |
- | 135 | 125 | 230 | 180 | ||
Cross section poles mm *D | 40 | 40/Ø95 | 60 | 60/Ø115 | 70 | ||
Pole height mm | 130 | 165 | 140 | 230 | 210 | ||
Temperature control ºC/ F | - max reach | 150ºC | 240ºC | 240ºC | 240ºC*2 | 240ºC*2 | |
- magnetic probe | yes | yes | yes | yes | yes | ||
- digital display | yes | yes | yes | yes | yes | ||
Time control | - max reach | 0-30 min. | 0-45 min. | 0-45 min. | 0-45 min. | 0-60 min. | |
- digital display | yes | yes | yes | yes | yes | ||
Sound signal | yes | yes | yes | yes | yes | ||
Error report | yes | yes | yes | yes | yes | ||
Temperature hold | yes | yes | yes | yes | yes | ||
Automatic power reduction | - | yes | - | yes | yes | ||
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | yes | ||
Thermal safety guard | yes | yes | yes | yes | yes | ||
Support for horizontal heating | - | yes | yes | yes | yes | ||
Dimensions mm (lxbxh.) | 460x240x280 | 600x220x275 | 340x290x380 | 440x370x420 | 630x365x470 | ||
Weight heater kg excl. Yokes | 21 (ze yokemi) |
23 (ze yokemi) |
31 | 37 | 53 | ||
Electric crane for yokes | - | - | - | - | - | ||
Alarm signal | - | - | - | - | optional | ||
Mobile | - | - | - | - | - |
![]() |
![]() |
![]() |
![]() |
||
Type BETEX | 40 RSD en RSDm (mobile) TURBO |
38 ZFD | 40 RMD TURBO |
SUPER Standard en DL-700 | |
---|---|---|---|---|---|
Facility power | 8 kVA | 12 kVA | 12 kVA | 24 kVA | |
Voltage/Amp | 400/500V 20A |
400/500V 30A |
400/500V 30A |
400/500V 60A |
|
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
Yokes, standard mm/ set 1 | optional | optional | optional | optional | |
Yokes, standard mm/ set 2 | 20, 30, 40, 60, 80 | 20, 30, 40, 60, 80 | 40, 60 ,80 | 40,50,60,80,100*3 | |
Swivel arm | yes | yes | yes | - | |
Max. weight ± kg | - bearings | 350 | 280 | 600 | 600 |
- other parts | 250 | 200 | 450 | 350 | |
Min. ID Ø: mm | 30/Ø155 | 30/Ø130 | 60/Ø170 | 60/85*3 | |
Max. OD :mm*A | 790 | 720/1080 *1 | 920 | 900/1300*3 | |
Max. width: mm *B | 315 | 340 | 365 | 400/700*3 | |
Max. width *C at horizontal heating: mm |
280 | 290 | 305 | 390/690*3 | |
Cross section poles mm *D | 80/Ø153 | 80 | Ø170/110x80 | 100*3 | |
Pole height mm | 320 | 340 | 305 | 390*3 | |
Temperature control ºC/ F | - max reach | 240ºC*2 | 240ºC*2 | 240ºC*2 | 240/350ºC*2 |
- magnetic probe | yes | yes | yes | yes | |
- digital display | yes | yes | yes | yes | |
Time control | - max reach | 0-60 min. | 0-99 min. | 0-99 min. | 0-99 min. |
- digital display | yes | yes | yes | yes | |
Sound signal | yes | yes | yes | yes | |
Error report | yes | yes | yes | yes | |
Temperature hold | yes | yes | yes | yes | |
Automatic power reduction | yes | yes | yes | yes | |
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | |
Thermal safety guard | yes | yes | yes | yes | |
Support for horizontal heating | yes | yes | yes | yes | |
Dimensions mm (lxbxh.) | 1200x640x1000 | 1200x640x1000 | 1200x640x1000 | 1000x500x1350*3 | |
Weight heater kg excl. Yokes | 65/105 | 125 | 205 | 220/320 kg*3 | |
Electric crane for yokes | - | - | - | optional | |
Alarm signal | optional | optional | optional | optional | |
Mobile | yes (40RSDm) | yes | yes | optional |
![]() |
![]() |
![]() |
![]() |
||
Type BETEX | SUPER TURBO |
GIANT Standard en DL-700 | GIANT Standard DL-700 / DL-1000 |
GIANT XL TURBO |
|
---|---|---|---|---|---|
Facility power | 24 kVA | 40 kVA | 48, 100 kVA | 40, 48, 100kVA | |
Voltage/Amp | 400/500V 60A |
400/500V 100A |
400/500V 120, 250A |
400/500V 100, 120, 250A |
|
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
Yokes, standard mm/ set 1 | Included | optional | optional | Included | |
Yokes, standard mm/ set 2 | 1 yoke | 60,80,100,150*3 | 60,80,100,150,200*3 | 1 yoke | |
Swivel arm | - | - | - | - | |
Max. weight ± kg | - bearings | 1200 | 1500/2000*3 | 3000/3500*3 | 1500/12000*3 |
- other parts | 900 | 900/1500*3 | 1500/2500*3 | <12000*3 | |
Min. ID Ø: mm | 175/Ø195 | 85*3 | 85/215*3 | 115/240*3 | |
Max. OD :mm*A | 1700 | 1400/1700*3 | 1700/2500*3 | 1400/2500*3 | |
Max. width: mm *B | 750 | 620/700*3 | 700/900*3 | 450/1020*3 | |
Max. width *C at horizontal heating: mm |
600 | 440/730*3 | 730/990*3 | 450/1000*3 | |
Cross section poles mm *D | 145/ Ø195 | 150*3 | 150/200*3 | 200*3 | |
Pole height mm | 595 | 660/740*3 | 740/1000*3 | 900*3 | |
Temperature control ºC/ F | - max reach | 240/350ºC*2 | 240/350ºC*2 | 240/350ºC*2 | 240/350ºC*2 |
- magnetic probe | yes | yes | yes | yes | |
- digital display | yes | yes | yes | yes | |
Time control | - max reach | 0-99 min. | 0-99 min. | 0-99 min. | 0-99 min. |
- digital display | yes | yes | yes | yes | |
Sound signal | yes | yes | yes | yes | |
Error report | yes | yes | yes | yes | |
Temperature hold | yes | yes | yes | yes | |
Automatic power reduction | yes | yes | yes | yes | |
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | |
Thermal safety guard | yes | yes | yes | yes | |
Support for horizontal heating | yes | yes | yes | yes | |
Dimensions mm (lxbxh.) | 1600x700x1300 | 1750x600x1470*3 | 2150x900x2210*3 | 2350x1000x1875*3 | |
Weight heater kg excl. Yokes | 450 kg (incl. yokes) |
660/800 kg*3 | 800/1700 kg*3 | 1800 kg*3 | |
Electric crane for yokes | - | optional | optional | optional | |
Alarm signal | optional | optional | optional | optional | |
Mobile | optional | optional | optional | optional |
*1 With adaptor yokes, only available for the Standard models
*2 On request: 350ºC with heavy duty sensor and extra isolation
*3 Subject to power and execution
On request:other voltage/ amperage/ higher temperature up to 480ºC
Heating times are subject to the relationship between:
• Min. bore and max. outside diameter, width, weight
• Required temperature and material type
• Available power
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
Bega Induction Heaters are designed to heat bearings, bushings, gear wheels, couplings or other metallic work pieces which form a closed electrical loop. This will facilitate mounting where an interference fit is required.
The heaters are designed to heat the work piece up to a maximum temperature of 240ºC (464ºF), with the exception of the 22 ELD series models where the temperature is limited to a maximum of 150ºC (302ºF) and special custom-designed heaters where the maximum temperature can be as high as 480ºC (896ºF).
The heater works in the same way as a transformer. The primary coil is the heater and the secondary coil is the work piece.
When the heater is switched on, a high voltage, low alternating current passes through the numerous windings of the primary coil. This induces a low voltage, high current in the work piece acting as the secondary coil. This high current results in the heating up of the work piece.
The current is only flowing in the work piece, hence it is only this which starts to heat up. The work piece is automatically demagnetised at the end of each heating cycle.
Dane techniczne
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Type BETEX |
22 ELD Portable |
24 RLD
|
22 ESD |
24 RSD TURBO |
38 ESD |
||
---|---|---|---|---|---|---|---|
Facility power | 3.6 kVA | 3.6 kVA | 3.6 kVA | 3.6 kVA | 8 kVA | ||
Voltage/Amp | 120V/15A 230V/16A |
120V/15A 230V/16A |
120V/15A 230V/16A |
120V15A 230V/16A |
400/500V 20A |
||
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | ||
Yokes, standard mm/ set 1 | 7,10,14,20,40 in box | 7,10,14,20,40 in heater |
14, 30, 60 | 14, 30, 60 | 30,70 | ||
Yokes, standard mm/ set 2 | 10, 14, 20, 30, 60 | 10, 14, 20, 30, 60 | 20,30,70 | ||||
Swivel arm | - | - | yes | yes | yes | ||
Max. weight ± kg | - bearings | 15 | 40 | 40 | 95 | 125 | |
- other parts | 10 | 25 | 25 | 50 | 75 | ||
Min. ID Ø: mm | 10 | 10/Ø100 | 15/Ø100 | 15/Ø120 | 30/Ø115 | ||
Max. OD :mm*A | 240 | 350 | 340/580 *1 | 520 | 480/720 *1 | ||
Max. width: mm *B | 120 | 135 | 150 | 200 | 200 | ||
Max. width *C at horizontal heating: mm |
- | 135 | 125 | 230 | 180 | ||
Cross section poles mm *D | 40 | 40/Ø95 | 60 | 60/Ø115 | 70 | ||
Pole height mm | 130 | 165 | 140 | 230 | 210 | ||
Temperature control ºC/ F | - max reach | 150ºC | 240ºC | 240ºC | 240ºC*2 | 240ºC*2 | |
- magnetic probe | yes | yes | yes | yes | yes | ||
- digital display | yes | yes | yes | yes | yes | ||
Time control | - max reach | 0-30 min. | 0-45 min. | 0-45 min. | 0-45 min. | 0-60 min. | |
- digital display | yes | yes | yes | yes | yes | ||
Sound signal | yes | yes | yes | yes | yes | ||
Error report | yes | yes | yes | yes | yes | ||
Temperature hold | yes | yes | yes | yes | yes | ||
Automatic power reduction | - | yes | - | yes | yes | ||
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | yes | ||
Thermal safety guard | yes | yes | yes | yes | yes | ||
Support for horizontal heating | - | yes | yes | yes | yes | ||
Dimensions mm (lxbxh.) | 460x240x280 | 600x220x275 | 340x290x380 | 440x370x420 | 630x365x470 | ||
Weight heater kg excl. Yokes | 21 (ze yokemi) |
23 (ze yokemi) |
31 | 37 | 53 | ||
Electric crane for yokes | - | - | - | - | - | ||
Alarm signal | - | - | - | - | optional | ||
Mobile | - | - | - | - | - |
![]() |
![]() |
![]() |
![]() |
||
Type BETEX | 40 RSD en RSDm (mobile) TURBO |
38 ZFD | 40 RMD TURBO |
SUPER Standard en DL-700 | |
---|---|---|---|---|---|
Facility power | 8 kVA | 12 kVA | 12 kVA | 24 kVA | |
Voltage/Amp | 400/500V 20A |
400/500V 30A |
400/500V 30A |
400/500V 60A |
|
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
Yokes, standard mm/ set 1 | optional | optional | optional | optional | |
Yokes, standard mm/ set 2 | 20, 30, 40, 60, 80 | 20, 30, 40, 60, 80 | 40, 60 ,80 | 40,50,60,80,100*3 | |
Swivel arm | yes | yes | yes | - | |
Max. weight ± kg | - bearings | 350 | 280 | 600 | 600 |
- other parts | 250 | 200 | 450 | 350 | |
Min. ID Ø: mm | 30/Ø155 | 30/Ø130 | 60/Ø170 | 60/85*3 | |
Max. OD :mm*A | 790 | 720/1080 *1 | 920 | 900/1300*3 | |
Max. width: mm *B | 315 | 340 | 365 | 400/700*3 | |
Max. width *C at horizontal heating: mm |
280 | 290 | 305 | 390/690*3 | |
Cross section poles mm *D | 80/Ø153 | 80 | Ø170/110x80 | 100*3 | |
Pole height mm | 320 | 340 | 305 | 390*3 | |
Temperature control ºC/ F | - max reach | 240ºC*2 | 240ºC*2 | 240ºC*2 | 240/350ºC*2 |
- magnetic probe | yes | yes | yes | yes | |
- digital display | yes | yes | yes | yes | |
Time control | - max reach | 0-60 min. | 0-99 min. | 0-99 min. | 0-99 min. |
- digital display | yes | yes | yes | yes | |
Sound signal | yes | yes | yes | yes | |
Error report | yes | yes | yes | yes | |
Temperature hold | yes | yes | yes | yes | |
Automatic power reduction | yes | yes | yes | yes | |
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | |
Thermal safety guard | yes | yes | yes | yes | |
Support for horizontal heating | yes | yes | yes | yes | |
Dimensions mm (lxbxh.) | 1200x640x1000 | 1200x640x1000 | 1200x640x1000 | 1000x500x1350*3 | |
Weight heater kg excl. Yokes | 65/105 | 125 | 205 | 220/320 kg*3 | |
Electric crane for yokes | - | - | - | optional | |
Alarm signal | optional | optional | optional | optional | |
Mobile | yes (40RSDm) | yes | yes | optional |
![]() |
![]() |
![]() |
![]() |
||
Type BETEX | SUPER TURBO |
GIANT Standard en DL-700 | GIANT Standard DL-700 / DL-1000 |
GIANT XL TURBO |
|
---|---|---|---|---|---|
Facility power | 24 kVA | 40 kVA | 48, 100 kVA | 40, 48, 100kVA | |
Voltage/Amp | 400/500V 60A |
400/500V 100A |
400/500V 120, 250A |
400/500V 100, 120, 250A |
|
Frequenz Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
Yokes, standard mm/ set 1 | Included | optional | optional | Included | |
Yokes, standard mm/ set 2 | 1 yoke | 60,80,100,150*3 | 60,80,100,150,200*3 | 1 yoke | |
Swivel arm | - | - | - | - | |
Max. weight ± kg | - bearings | 1200 | 1500/2000*3 | 3000/3500*3 | 1500/12000*3 |
- other parts | 900 | 900/1500*3 | 1500/2500*3 | <12000*3 | |
Min. ID Ø: mm | 175/Ø195 | 85*3 | 85/215*3 | 115/240*3 | |
Max. OD :mm*A | 1700 | 1400/1700*3 | 1700/2500*3 | 1400/2500*3 | |
Max. width: mm *B | 750 | 620/700*3 | 700/900*3 | 450/1020*3 | |
Max. width *C at horizontal heating: mm |
600 | 440/730*3 | 730/990*3 | 450/1000*3 | |
Cross section poles mm *D | 145/ Ø195 | 150*3 | 150/200*3 | 200*3 | |
Pole height mm | 595 | 660/740*3 | 740/1000*3 | 900*3 | |
Temperature control ºC/ F | - max reach | 240/350ºC*2 | 240/350ºC*2 | 240/350ºC*2 | 240/350ºC*2 |
- magnetic probe | yes | yes | yes | yes | |
- digital display | yes | yes | yes | yes | |
Time control | - max reach | 0-99 min. | 0-99 min. | 0-99 min. | 0-99 min. |
- digital display | yes | yes | yes | yes | |
Sound signal | yes | yes | yes | yes | |
Error report | yes | yes | yes | yes | |
Temperature hold | yes | yes | yes | yes | |
Automatic power reduction | yes | yes | yes | yes | |
Automatyczna demagnetyzacja, <2A/cm | yes | yes | yes | yes | |
Thermal safety guard | yes | yes | yes | yes | |
Support for horizontal heating | yes | yes | yes | yes | |
Dimensions mm (lxbxh.) | 1600x700x1300 | 1750x600x1470*3 | 2150x900x2210*3 | 2350x1000x1875*3 | |
Weight heater kg excl. Yokes | 450 kg (incl. yokes) |
660/800 kg*3 | 800/1700 kg*3 | 1800 kg*3 | |
Electric crane for yokes | - | optional | optional | optional | |
Alarm signal | optional | optional | optional | optional | |
Mobile | optional | optional | optional | optional |
*1 With adaptor yokes, only available for the Standard models
*2 On request: 350ºC with heavy duty sensor and extra isolation
*3 Subject to power and execution
On request:other voltage/ amperage/ higher temperature up to 480ºC
Heating times are subject to the relationship between:
• Min. bore and max. outside diameter, width, weight
• Required temperature and material type
• Available power