Objective: To heat a stainless steel tube while avoiding oxidation for an annealing application; the end product is a handle for a dental tool.
Material: Steel tube, hydrogen gas, bell jar and fixture
Temperature: 1038 °C
Frequency: 270 kHz
Equipment: Ambrell EASYHEAT LI 4 kW, 150-400 kHz induction heating system equipped with a remote workhead containing two 1.5 μF capacitors for a total capacitance of 0.75 μF, single position three-turn helical induction heating coil.
Process: The stainless steel tube was placed inside the tube and connected to hydrogen. A bell jar was placed over the tube to trap the hydrogen gas. Hydrogen was allowed to flow into the bell jar for one minute. Power was then turned on and the part began to heat. The part achieved annealing temperature within five seconds. Power was turned off and the part was allowed to cool for one minute.
Results:
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
Objective: To heat a stainless steel tube while avoiding oxidation for an annealing application; the end product is a handle for a dental tool.
Material: Steel tube, hydrogen gas, bell jar and fixture
Temperature: 1038 °C
Frequency: 270 kHz
Equipment: Ambrell EASYHEAT LI 4 kW, 150-400 kHz induction heating system equipped with a remote workhead containing two 1.5 μF capacitors for a total capacitance of 0.75 μF, single position three-turn helical induction heating coil.
Process: The stainless steel tube was placed inside the tube and connected to hydrogen. A bell jar was placed over the tube to trap the hydrogen gas. Hydrogen was allowed to flow into the bell jar for one minute. Power was then turned on and the part began to heat. The part achieved annealing temperature within five seconds. Power was turned off and the part was allowed to cool for one minute.
Results: