Multifunction network analyzer, suitable for three-phase three or four wires systems unbalanced load, even with distorted waveforms. It displays the main electrical measurements of an electrical network, including active and reactive energy counting. The 4 front push-buttons allow immediate display of the relevant measurements concerned without scrolling all display pages. Thank to the display digits size and to five backlight setting the meter is easy readable even to at large distances and with all light conditions. The QUBO 96H version performs also “advanced” measurements, which allow a very efficient monitoring and provide additional information about the system operating conditions, also by means of different communication protocols.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point position | Autmatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Measuring type | True RMS |
Basic accuracy | ±0.5% |
Rated voltage | 100, 400V |
Rated current | 1, 5A |
Input range | 10-120% UN, 5-120% IN |
Frequency | 45…65Hz |
VT ratio (max. primary) | 1MV |
CT ratio (max. primary) | 15kA |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circuits consumption | <0.5VA |
Voltage circuits consumption | <0.5VA |
Supply voltage | 230V (45…65Hz), 6VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimensions
Code
QUBO 96H | Q96P3H005 | - | CQ | - | - | |
---|---|---|---|---|---|---|
Communication | RS485 Modbus | M | ||||
Modbus TCP + WebServer + internal memory | E | |||||
Modbus TCP + WebServer + Gateway | G | |||||
IEC61850 | I | |||||
Profibus DP V0 | P | |||||
Johnson Controls N2 open | J | |||||
Aux. power supply | 220-240V AC | 2 | ||||
20-60V AC/DC | L | |||||
80-260V AC/DC | H | |||||
Option | None | - | ||||
2 outputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidrirectionality | Yes |
Alarm outputs | |
Activation delay setting | Prog. 0…999s |
Programmability | Varibal, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Prog 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parameters | Parity [&] stop prog. |
Addressing range | 1…247 |
ModBus TCP/Webserver | |
Ethernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
IEC61850 | |
Ethernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
ProfiBus DP 0V | |
Network | NRZ asynchronous |
Buad rate | 9.6kbit/s…12Mbit/s |
Addressing range | 1…99 prog. |
Complies to | EN 50170 |
Johnson Controls N2 OPEN | |
Inteface | RS485 |
Speed (bps) | 9600 |
Parity | Nie |
Addressing range | 1…247 prog. |
Wiring diagrams
Three-phase, three wires system
Three-phase four wires system
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
Multifunction network analyzer, suitable for three-phase three or four wires systems unbalanced load, even with distorted waveforms. It displays the main electrical measurements of an electrical network, including active and reactive energy counting. The 4 front push-buttons allow immediate display of the relevant measurements concerned without scrolling all display pages. Thank to the display digits size and to five backlight setting the meter is easy readable even to at large distances and with all light conditions. The QUBO 96H version performs also “advanced” measurements, which allow a very efficient monitoring and provide additional information about the system operating conditions, also by means of different communication protocols.
Rated data
Display | Backlit LCD |
---|---|
Digits height | 13.5mm |
Max. indication | 4 digits |
Decimal point position | Autmatic |
Adjustable backlight | 5 levels |
Readings update | <0.5s |
Measuring type | True RMS |
Basic accuracy | ±0.5% |
Rated voltage | 100, 400V |
Rated current | 1, 5A |
Input range | 10-120% UN, 5-120% IN |
Frequency | 45…65Hz |
VT ratio (max. primary) | 1MV |
CT ratio (max. primary) | 15kA |
Continuous overload | 2 x IN, 1.2 x UN |
Short-term overload | 20 x IN, 2 x UN (300msec.) |
Current circuits consumption | <0.5VA |
Voltage circuits consumption | <0.5VA |
Supply voltage | 230V (45…65Hz), 6VA |
Operating temperature | 0…23…50°C |
Storage temperature | -30…70°C |
Housing material | UL 94-V0 |
Protection for housing | IP50 |
Protection for terminals | IP20 |
Galvanic insulation | In./out. |
Installation category | III, 300V, P.D. 2 |
Dimensions
Code
QUBO 96H | Q96P3H005 | - | CQ | - | - | |
---|---|---|---|---|---|---|
Communication | RS485 Modbus | M | ||||
Modbus TCP + WebServer + internal memory | E | |||||
Modbus TCP + WebServer + Gateway | G | |||||
IEC61850 | I | |||||
Profibus DP V0 | P | |||||
Johnson Controls N2 open | J | |||||
Aux. power supply | 220-240V AC | 2 | ||||
20-60V AC/DC | L | |||||
80-260V AC/DC | H | |||||
Option | None | - | ||||
2 outputs alarm/pulses | U |
Measured value
Additional technical data
Energy counting | |
---|---|
Number of digits | 10 |
Maximum counting | 2x109 |
Accuracy class | 1 (kWh), 2 (kvarh) |
Bidrirectionality | Yes |
Alarm outputs | |
Activation delay setting | Prog. 0…999s |
Programmability | Varibal, value, direction |
Pulse output | |
Programmability | Pulse value |
Pulse duration | Prog 30…1000ms |
Modbus RTU | |
Interface | RS485 |
Speed (bps) | 9600/19200/38400/57600 |
Communication parameters | Parity [&] stop prog. |
Addressing range | 1…247 |
ModBus TCP/Webserver | |
Ethernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
IEC61850 | |
Ethernet interface | IEEE 802.3 (u) 10 Base T/100 Base TX |
Wiring | RJ45 |
Speed | 10/100 Mbit/s |
Duplex | Half/full |
ProfiBus DP 0V | |
Network | NRZ asynchronous |
Buad rate | 9.6kbit/s…12Mbit/s |
Addressing range | 1…99 prog. |
Complies to | EN 50170 |
Johnson Controls N2 OPEN | |
Inteface | RS485 |
Speed (bps) | 9600 |
Parity | Nie |
Addressing range | 1…247 prog. |