

Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографии предназначены только для информационных целей. Посмотреть спецификацию продукта
please use latin characters
The characteristics of NA003 as a good grid and system protector:
Iconography that presents where NA003 have to be installed:
Rated data:
Supply circuit | |
---|---|
Terminals | A1 (L), A2 (N) |
Supply voltage | DC: 24V AC: 110-230V |
Supply voltage tolerance | DC: ±10% AC: ±30% |
Rated frequency | 50/60Hz |
Tolerance of rated frequency | 48 – 63Hz |
Rated surge voltage | 4kV |
Measuring circuit | |
Terminals | L1, L2, L3, N |
Measuring input | 3x400V AC |
Measurand | line to line voltage, line to neutral voltage, 10 minutes average voltage, frequency, rate of change of frequency (RoCoF), phase shift (PShift) |
Measuring ranges | |
Line to line voltage | 0-560V AC |
Line to neutral voltage | 0-325V AC |
Frequency | 40-60Hz |
RoCoF | 100mHz/s-2Hz/s |
PShift | 1-15° |
Digital inputs | |
Terminals | I1 i ⊥, I2 i ⊥, I3 i ⊥, I4/I5 i ⊥ |
Type of contact | potential free |
Min. switching voltage/current | 24V/5mA |
Output circuit | |
Terminals | 11-12-14; 21-22-24; 31-32-34; |
Number of contacts | 3 changeover |
Contact material | AgNi |
Rated current | 5A/250V AC |
Electrical endurance | 100x103switching cycles (AC-1) |
Mechanical endurance | 15x106switching cycles |
Accuracy | |
Base accuracy (voltage) | <0,5% @ 25°C |
Temperature influence | <0,01%/°C |
Resolution | 10mV |
Base accuracy (frequency) | <0,01 Hz dla 25°C |
Temperature influence | <0,00002Hz/°C |
Resolution | 1mHz |
Isolation data | |
Rated insulation voltage | 400V |
Supply circuit/measuring circuit | protective separation |
Supply circuit/output circuit | protective separation |
Supply circuit/digital inputs | protective separation |
Output circuit/measuring circuit | protective separation |
Output circuit/digital inputs | protective separation |
Environmental conditions | |
Ambient temperature operation | -25…55°C |
Ambient temperature storage | -40…70°C |
Ambient temperature display | -15…55°C |
Relative humidity | 5…95% (non-condensing) |
Weight | 300g |
Electrical connection | |
Wire size | max. 2,5mm2 |
Stripping length | max. 8mm |
Electrical strength | max. 450V/16A (digital inputs, relay outputs) max. 750V/16A (measuring inputs) |
Torque | max. 0,5Nm |
Screw | M3, slotted recess for screw driver 0,6 x 3,5mm |
Sealing wire | dMAX = 0,8mm |
In order to ensure the proper function during power failures, an external UPS has to be used.
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The characteristics of NA003 as a good grid and system protector:
Iconography that presents where NA003 have to be installed:
Rated data:
Supply circuit | |
---|---|
Terminals | A1 (L), A2 (N) |
Supply voltage | DC: 24V AC: 110-230V |
Supply voltage tolerance | DC: ±10% AC: ±30% |
Rated frequency | 50/60Hz |
Tolerance of rated frequency | 48 – 63Hz |
Rated surge voltage | 4kV |
Measuring circuit | |
Terminals | L1, L2, L3, N |
Measuring input | 3x400V AC |
Measurand | line to line voltage, line to neutral voltage, 10 minutes average voltage, frequency, rate of change of frequency (RoCoF), phase shift (PShift) |
Measuring ranges | |
Line to line voltage | 0-560V AC |
Line to neutral voltage | 0-325V AC |
Frequency | 40-60Hz |
RoCoF | 100mHz/s-2Hz/s |
PShift | 1-15° |
Digital inputs | |
Terminals | I1 i ⊥, I2 i ⊥, I3 i ⊥, I4/I5 i ⊥ |
Type of contact | potential free |
Min. switching voltage/current | 24V/5mA |
Output circuit | |
Terminals | 11-12-14; 21-22-24; 31-32-34; |
Number of contacts | 3 changeover |
Contact material | AgNi |
Rated current | 5A/250V AC |
Electrical endurance | 100x103switching cycles (AC-1) |
Mechanical endurance | 15x106switching cycles |
Accuracy | |
Base accuracy (voltage) | <0,5% @ 25°C |
Temperature influence | <0,01%/°C |
Resolution | 10mV |
Base accuracy (frequency) | <0,01 Hz dla 25°C |
Temperature influence | <0,00002Hz/°C |
Resolution | 1mHz |
Isolation data | |
Rated insulation voltage | 400V |
Supply circuit/measuring circuit | protective separation |
Supply circuit/output circuit | protective separation |
Supply circuit/digital inputs | protective separation |
Output circuit/measuring circuit | protective separation |
Output circuit/digital inputs | protective separation |
Environmental conditions | |
Ambient temperature operation | -25…55°C |
Ambient temperature storage | -40…70°C |
Ambient temperature display | -15…55°C |
Relative humidity | 5…95% (non-condensing) |
Weight | 300g |
Electrical connection | |
Wire size | max. 2,5mm2 |
Stripping length | max. 8mm |
Electrical strength | max. 450V/16A (digital inputs, relay outputs) max. 750V/16A (measuring inputs) |
Torque | max. 0,5Nm |
Screw | M3, slotted recess for screw driver 0,6 x 3,5mm |
Sealing wire | dMAX = 0,8mm |
In order to ensure the proper function during power failures, an external UPS has to be used.
Не удаётся отправить вашу оценку отзыва
Пожаловаться на комментарий
Жалоба отправлена
Не удаётся отправить вашу жалобу
Оставьте свой отзыв
Отзыв отправлен
Не удаётся отправить отзыв