The Multichannel earth leakage relays COMBI 6 have been designed for the monitoring and protection of up to 6 independent systems. A single instrument of 3 DIN modules size allows a considerable optimization of the overall dimensions and of the wiring connection procedures, thanks also to the presence of withdrawable terminals blocks for the connections. The 4 front keys allow immediate programming, further simplified by the copy/paste function available in the setting menu. A push button dedicated to the Scroll of the channels allows the selection of the input to be displayed, while in case of trip intervention, the display will automatically show the last tripped channel, and the relative LED will be ON.
Technical data
Main features
Technical data
Display | Color, backlit LCD |
Resolution | 3 digits |
Decimal point position | Automatic |
Bargraph | 10 levels |
Measurement type | Type AC, A, F, B - TRMS |
Display refresh rate | Every 500ms (average value for the period) |
Bandwidth | DC; 2.5Hz – 3kHz |
Accuracy | ±0.5% |
Voltage flicker filter | Compliant with IEC 62423, VDE 0664-T-100 Fire protection 300mA |
Third harmonic filter | Attenuation of 80% at 150Hz |
Setting range for current IΔN | 0.03 ÷ 30 A; TDA… - TDC… 30 ÷ 500mA; 500mA ÷ 1.5A (TC) TDB…3CM 300mA ÷ 5A; 5A ÷ 15AQ (TC) TDB…003 |
Setting range for operating current IΔNO | 80% - 98% IΔN |
Contact configuration | 6x SPST (COM, NO1, NO2, NO3, NO4, NO5, NO6) |
Setting range for DC operating current IΔN | 5% - 100% IΔN DC(min. 6mAdc) |
Time-current characteristic settings (current-dependent times) | Instantaneous: IΔN = 30mA Selective 60ms: IΔN > 30mA Delayed 20ms – 30s: IΔN > 30mA |
Time-current characteristic settings (current-independent times) | Delayed 20ms: IΔN = 30mA Delayed 20ms – 30s: IΔN > 30mA |
Contact | SPDT (COM, NO, NC) |
Rated load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Protection | Standard (ND) or increased (NE) |
Isolation levels | In accordance with IEC 61010-1, IEC 60947-1 |
Operating temperature | 0…+50˚C |
Storage temperature | -30˚C…+70˚C |
Self-extinguishing housing (material) | UL 94-V0 |
Protection level for built-in applications | IP52 |
Protection level for terminal applications | IP20 |
Compliant with | EN 60947-2 |
Additional technical data
Automatic connection test | Secondary voltage impulse |
Alarm (optional) | SPDT (COM, NO, NC) |
Alarm settings | Disabled, 5-100% IΔN |
Special function | Reclose; 2nd Trip and IΔnDC |
Relay rated load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
PhotoMOS Transistor Connector rated load | 100mA, 250VAC/DC (CAT II) – 150VAC/DC (CAT III) 350VPK-PK (with overload) |
Protection | Standard (ND) or increased (NE) |
Test-Reset Input (optional) | Signal > 2s |
Modbus RTU (optional) | Isolated RS485, A+, B-, GND (option) |
Data transfer rate | 9600, 19200, 38400, 57600 bit/s |
Programmable parameters | Parity bit and STOP |
Programmable addresses | 1 – 247 |
Oscilloscope function | 120 samples (12-bit), with time and amplitude base settings |
Real-time clock (optional) | RTC with backup battery power |
Event logging | Last 10 events with time stamps |
Type designation | X _ _ D B 3 | _ _ _ | X52U_____ | _ _ _ | _ | _ | |
Input Type | Type B | 6 inputs Type B | X52UB64DC | ||||
Type A-F | 6 inputs Type A-F | X52UL6030 | |||||
Mixed | 1 input Type B | 5 inputs Type A-F | X52UX6C15 | ||||
2 inputs Type B | 4 inputs Type A-F | X52UX6C24 | |||||
3 inputs Type B | 3 inputs Type A-F | X52UX6C33 | |||||
4 inputs Type B | 2 inputs Type A-F | X52UX6C42 | |||||
5 inputs Type B | 1 input Type A-F | X52UX6C51 | |||||
Options | No options | X60 | |||||
Alarm + input reset | R61 | ||||||
Modbus RTU | M60 | ||||||
Power supply | 20 – 60VAC/DC <4VA/2.5W | L | |||||
80 – 260V AC/DC <6.5VA/2.5W | H | ||||||
Real-time clock | No | - | |||||
Yes | C |
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The Multichannel earth leakage relays COMBI 6 have been designed for the monitoring and protection of up to 6 independent systems. A single instrument of 3 DIN modules size allows a considerable optimization of the overall dimensions and of the wiring connection procedures, thanks also to the presence of withdrawable terminals blocks for the connections. The 4 front keys allow immediate programming, further simplified by the copy/paste function available in the setting menu. A push button dedicated to the Scroll of the channels allows the selection of the input to be displayed, while in case of trip intervention, the display will automatically show the last tripped channel, and the relative LED will be ON.
Technical data
Main features
Technical data
Display | Color, backlit LCD |
Resolution | 3 digits |
Decimal point position | Automatic |
Bargraph | 10 levels |
Measurement type | Type AC, A, F, B - TRMS |
Display refresh rate | Every 500ms (average value for the period) |
Bandwidth | DC; 2.5Hz – 3kHz |
Accuracy | ±0.5% |
Voltage flicker filter | Compliant with IEC 62423, VDE 0664-T-100 Fire protection 300mA |
Third harmonic filter | Attenuation of 80% at 150Hz |
Setting range for current IΔN | 0.03 ÷ 30 A; TDA… - TDC… 30 ÷ 500mA; 500mA ÷ 1.5A (TC) TDB…3CM 300mA ÷ 5A; 5A ÷ 15AQ (TC) TDB…003 |
Setting range for operating current IΔNO | 80% - 98% IΔN |
Contact configuration | 6x SPST (COM, NO1, NO2, NO3, NO4, NO5, NO6) |
Setting range for DC operating current IΔN | 5% - 100% IΔN DC(min. 6mAdc) |
Time-current characteristic settings (current-dependent times) | Instantaneous: IΔN = 30mA Selective 60ms: IΔN > 30mA Delayed 20ms – 30s: IΔN > 30mA |
Time-current characteristic settings (current-independent times) | Delayed 20ms: IΔN = 30mA Delayed 20ms – 30s: IΔN > 30mA |
Contact | SPDT (COM, NO, NC) |
Rated load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Protection | Standard (ND) or increased (NE) |
Isolation levels | In accordance with IEC 61010-1, IEC 60947-1 |
Operating temperature | 0…+50˚C |
Storage temperature | -30˚C…+70˚C |
Self-extinguishing housing (material) | UL 94-V0 |
Protection level for built-in applications | IP52 |
Protection level for terminal applications | IP20 |
Compliant with | EN 60947-2 |
Additional technical data
Automatic connection test | Secondary voltage impulse |
Alarm (optional) | SPDT (COM, NO, NC) |
Alarm settings | Disabled, 5-100% IΔN |
Special function | Reclose; 2nd Trip and IΔnDC |
Relay rated load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
PhotoMOS Transistor Connector rated load | 100mA, 250VAC/DC (CAT II) – 150VAC/DC (CAT III) 350VPK-PK (with overload) |
Protection | Standard (ND) or increased (NE) |
Test-Reset Input (optional) | Signal > 2s |
Modbus RTU (optional) | Isolated RS485, A+, B-, GND (option) |
Data transfer rate | 9600, 19200, 38400, 57600 bit/s |
Programmable parameters | Parity bit and STOP |
Programmable addresses | 1 – 247 |
Oscilloscope function | 120 samples (12-bit), with time and amplitude base settings |
Real-time clock (optional) | RTC with backup battery power |
Event logging | Last 10 events with time stamps |
Type designation | X _ _ D B 3 | _ _ _ | X52U_____ | _ _ _ | _ | _ | |
Input Type | Type B | 6 inputs Type B | X52UB64DC | ||||
Type A-F | 6 inputs Type A-F | X52UL6030 | |||||
Mixed | 1 input Type B | 5 inputs Type A-F | X52UX6C15 | ||||
2 inputs Type B | 4 inputs Type A-F | X52UX6C24 | |||||
3 inputs Type B | 3 inputs Type A-F | X52UX6C33 | |||||
4 inputs Type B | 2 inputs Type A-F | X52UX6C42 | |||||
5 inputs Type B | 1 input Type A-F | X52UX6C51 | |||||
Options | No options | X60 | |||||
Alarm + input reset | R61 | ||||||
Modbus RTU | M60 | ||||||
Power supply | 20 – 60VAC/DC <4VA/2.5W | L | |||||
80 – 260V AC/DC <6.5VA/2.5W | H | ||||||
Real-time clock | No | - | |||||
Yes | C |