The X...DL3 series earth leakage relays are designed to measure the leakage or unbalan-ced currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to the defective system. Thanks to their distinctive feature (the displaying of the leakage current) it is possible to continuously monitor the insulation state and to program the preventive maintenance in order to avoid unexpected power breaks
Main function:
Display | multicolor backlight LCD |
---|---|
Maximun indication | 3 digits |
Dot point position | automatic |
Histogram | 10 levels |
Residual curent measure | Type AC, A, F - TRMS |
Display refresh | 500ms (average value) |
Measurement bandwidth | 2,5Hz – 2,5kHz |
Base precision | ±0,5% |
Selectable antifibrillation LPF | IEC 62423, VDE 0664-T-100 |
Selectable 3rd harmonic LPF | attenuation 80% @ 150Hz |
Residual operating current setting IΔN | 30mA – 30A |
Residual not operating current setting IΔNO | 80% - 98% IΔN |
Limiting no-actuating time setting ΔtNO | Istantaneous 20ms – 30s |
Selectable inverse time-current characteristic |
Istantaneous: IΔN = 30mA Selective 60ms: IΔN > 30mA delayed 20ms – 30s: IΔN > 30mA |
Selectable constant time-current characteristic |
delayed 20ms: IΔN = 30mA delayed 20ms – 30s: IΔN > 30mA |
Trip contact | SPDT (COM, NO, NC) |
Nominal load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Safety | Standardowa (ND) lub zwiększona (NE) |
Insulation and safety | IEC 61010-1, IEC 60947-1 |
Operating temperature | 0…+50˚C |
Storage temperature | -30˚C…+70˚C |
Self estinguishing thermoplastic material | UL 94-V0 |
Protection degree for housing | IP20 (X35DL3); IP52 (X48DL3 – X72DL3) |
Protection degree for terminals | IP20 |
According to | EN 60947-2, EN62423 |
Automatic sensor connection test | Iniezione corrente sul secondario secondary current injection |
---|---|
Alarm (option) | SPST (COM, NO) |
Alarm setting | OFF, 5-100% IΔN |
Activation delay | 20ms-30s |
Release delay | LATCH - 20ms – 30s |
Relay nominal load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Photo-mos nominal load | 100mA, 250VAC/DC (CAT II) – 150VAC/DC (CAT III) 350VPK-PK (including overvoltage) |
Safety | Standard (ND) or positive (NE) |
Test-Reste input | Command > 2s |
Contact closing voltage presence, HV option | 50 - 275VAC/DC (to be specifed) |
Modbus RTU (option) | RS485 insulated, A+, B-, GND (optional) |
Baud Rate | 9600, 19200, 38400, 57600 bit/s |
Programmable parameters | Paity and stop bits |
Address programmable | 1 – 247 |
Scope function | 120 samples (12bits), with amplitude and time scales |
Real time clock (option) | RTC with Battery backup |
Archive event store | lat 10 events, with Timestamp |
Type | X _ _ D L 3 | _ _ _ | _ _ _ | _ | _ | |
---|---|---|---|---|---|---|
Size | DIN | X 3 5 D L 3 | ||||
48x48mm | X 4 8 D L 3 | |||||
Current range | 30mA – 30A fN = 50 – 60Hz | 0 3 0 | ||||
300mA – 300A fN = 50 – 60Hz | 3 0 0 | |||||
30mA – 30A fN = 400Hz | Q 3 0 | |||||
300mA – 300A fN = 400Hz | Q 3 C | |||||
Options | Test reste input | R 1 0 | ||||
Test reset input + photo-mos alarm | R 1 L | |||||
RS485 Modbus RTU + Photo-mos alarm | M 1 L | |||||
RS485 Modbus RTU + Test reset input | B 1 0 | |||||
Hv test reset input + Rele alarm | H 1 1 | |||||
Aux, supply | 230VAC, ±10%; 3VA | 2 | ||||
20 – 60VAC/DC <4VA/2,5W | L | |||||
80 – 260VAC/DC <6,5VA/2,5W | H | |||||
Real time clock | no | |||||
yes | C | |||||
type | X 7 2 D L 3 | _ _ _ | _ _ _ | _ | _ | |
Current range | 30mA – 30A fN = 50 – 60Hz | 0 3 0 | ||||
300mA – 300A fN = 50 – 60Hz | 3 0 0 | |||||
30mA – 30A fN = 400Hz | Q 3 0 | |||||
300mA – 300A fN = 400Hz | Q 3 C | |||||
Options | Test reset input | R 1 1 | ||||
HV Test reset input | R 1 L | |||||
RS485 Modbus RTU + Test reset input | B 1 1 | |||||
RS485 Modbus RTU + HV Test reset input | A 1 1 | |||||
Aux, supply | 230VAC, ±10%; 3VA | 2 | ||||
20 – 60VAC/DC <4VA/2,5W | L | |||||
80 – 260VAC/DC <6,5VA/2,5W | H | |||||
Real timeclock | no | |||||
yes | C |
X35DL3 |
X48DL3 |
![]() |
![]() |
X72DL3 |
4C7296XK |
![]() |
![]() |
Wiring diagrams X35DL3 – X48DL3 |
Wiring diagrams X72DL3 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The X...DL3 series earth leakage relays are designed to measure the leakage or unbalan-ced currents caused by conductors or appliances insulation losses and to react, in case the set limits are exceeded, switching off the power supply to the defective system. Thanks to their distinctive feature (the displaying of the leakage current) it is possible to continuously monitor the insulation state and to program the preventive maintenance in order to avoid unexpected power breaks
Main function:
Display | multicolor backlight LCD |
---|---|
Maximun indication | 3 digits |
Dot point position | automatic |
Histogram | 10 levels |
Residual curent measure | Type AC, A, F - TRMS |
Display refresh | 500ms (average value) |
Measurement bandwidth | 2,5Hz – 2,5kHz |
Base precision | ±0,5% |
Selectable antifibrillation LPF | IEC 62423, VDE 0664-T-100 |
Selectable 3rd harmonic LPF | attenuation 80% @ 150Hz |
Residual operating current setting IΔN | 30mA – 30A |
Residual not operating current setting IΔNO | 80% - 98% IΔN |
Limiting no-actuating time setting ΔtNO | Istantaneous 20ms – 30s |
Selectable inverse time-current characteristic |
Istantaneous: IΔN = 30mA Selective 60ms: IΔN > 30mA delayed 20ms – 30s: IΔN > 30mA |
Selectable constant time-current characteristic |
delayed 20ms: IΔN = 30mA delayed 20ms – 30s: IΔN > 30mA |
Trip contact | SPDT (COM, NO, NC) |
Nominal load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Safety | Standardowa (ND) lub zwiększona (NE) |
Insulation and safety | IEC 61010-1, IEC 60947-1 |
Operating temperature | 0…+50˚C |
Storage temperature | -30˚C…+70˚C |
Self estinguishing thermoplastic material | UL 94-V0 |
Protection degree for housing | IP20 (X35DL3); IP52 (X48DL3 – X72DL3) |
Protection degree for terminals | IP20 |
According to | EN 60947-2, EN62423 |
Automatic sensor connection test | Iniezione corrente sul secondario secondary current injection |
---|---|
Alarm (option) | SPST (COM, NO) |
Alarm setting | OFF, 5-100% IΔN |
Activation delay | 20ms-30s |
Release delay | LATCH - 20ms – 30s |
Relay nominal load | 6A, 250VAC AC1; 6A, 24VDC DC1 3A, 250VAC AC15; 2A, 24VDC DC13 (IEC60947-5-1) |
Photo-mos nominal load | 100mA, 250VAC/DC (CAT II) – 150VAC/DC (CAT III) 350VPK-PK (including overvoltage) |
Safety | Standard (ND) or positive (NE) |
Test-Reste input | Command > 2s |
Contact closing voltage presence, HV option | 50 - 275VAC/DC (to be specifed) |
Modbus RTU (option) | RS485 insulated, A+, B-, GND (optional) |
Baud Rate | 9600, 19200, 38400, 57600 bit/s |
Programmable parameters | Paity and stop bits |
Address programmable | 1 – 247 |
Scope function | 120 samples (12bits), with amplitude and time scales |
Real time clock (option) | RTC with Battery backup |
Archive event store | lat 10 events, with Timestamp |
Type | X _ _ D L 3 | _ _ _ | _ _ _ | _ | _ | |
---|---|---|---|---|---|---|
Size | DIN | X 3 5 D L 3 | ||||
48x48mm | X 4 8 D L 3 | |||||
Current range | 30mA – 30A fN = 50 – 60Hz | 0 3 0 | ||||
300mA – 300A fN = 50 – 60Hz | 3 0 0 | |||||
30mA – 30A fN = 400Hz | Q 3 0 | |||||
300mA – 300A fN = 400Hz | Q 3 C | |||||
Options | Test reste input | R 1 0 | ||||
Test reset input + photo-mos alarm | R 1 L | |||||
RS485 Modbus RTU + Photo-mos alarm | M 1 L | |||||
RS485 Modbus RTU + Test reset input | B 1 0 | |||||
Hv test reset input + Rele alarm | H 1 1 | |||||
Aux, supply | 230VAC, ±10%; 3VA | 2 | ||||
20 – 60VAC/DC <4VA/2,5W | L | |||||
80 – 260VAC/DC <6,5VA/2,5W | H | |||||
Real time clock | no | |||||
yes | C | |||||
type | X 7 2 D L 3 | _ _ _ | _ _ _ | _ | _ | |
Current range | 30mA – 30A fN = 50 – 60Hz | 0 3 0 | ||||
300mA – 300A fN = 50 – 60Hz | 3 0 0 | |||||
30mA – 30A fN = 400Hz | Q 3 0 | |||||
300mA – 300A fN = 400Hz | Q 3 C | |||||
Options | Test reset input | R 1 1 | ||||
HV Test reset input | R 1 L | |||||
RS485 Modbus RTU + Test reset input | B 1 1 | |||||
RS485 Modbus RTU + HV Test reset input | A 1 1 | |||||
Aux, supply | 230VAC, ±10%; 3VA | 2 | ||||
20 – 60VAC/DC <4VA/2,5W | L | |||||
80 – 260VAC/DC <6,5VA/2,5W | H | |||||
Real timeclock | no | |||||
yes | C |
X35DL3 |
X48DL3 |
![]() |
![]() |
X72DL3 |
4C7296XK |
![]() |
![]() |