• Continuous operating temperatures: -60 °C to +150 °C. • All colours including two-coloured. • UL approval as per standard UL 758 - File no.: E101965. • Cabling for household electrical heating appliances, rotating machines, lighting. • Other nominal cross-sections: contact us |
![]() 1 • Bare copper, tin-plated, nickel-plated or silver-plated core. |
Style | 3099 | 3132 | 3123 | 3133 | 3134 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
105 °C -300 V(cUL 600V) | 105 °C - 300 V | 105 °C -600 V | 105 °C -600 V | 105 °C -600 V | |||||||
Nominal cross-section | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | [mm] | [mm] | |||||
26 | 0.13 | – | – | 0.38 | 1.2 | 0.76 | 2.0 | 0.76 | 2.0 | – | – |
24 | 0.22 | – | – | 0.38 | 1.4 | 0.76 | 2.1 | 0.76 | 2.1 | – | – |
22 | 0.34 | – | – | 0.38 | 1.55 | 0.76 | 2.35 | 0.76 | 2.35 | – | – |
– | 0.5 | – | – | 0.38 | 1.7 | 0.76 | 2.5 | 0.76 | 2.5 | – | – |
20 | 0.6 | 0.76 | 2.5 | 0.38 | 1.75 | 0.76 | 2.5 | 0.76 | 2.5 | – | – |
– | 0.75 | 0.76 | 2.7 | 0.38 | 1.9 | 0.76 | 2.7 | 0.76 | 2.7 | – | – |
18 | 0.93 | 0.76 | 2.8 | 0.38 | 2.0 | 0.76 | 2.8 | 0.76 | 2.7 | 0,76 | 2,7 |
– | 1 | 0.76 | 2.9 | 0.38 | 2.1 | 0.76 | 2.8 | 0.76 | 2.8 | 0,76 | 2,9 |
16 | 1.34 | 0.76 | 3.1 | 0.38 | 2.3 | 0.76 | 3.0 | 0.76 | 3.1 | 0,76 | 3,1 |
– | 1.5 | 0.76 | 3.2 | 0.38 | 2.4 | 0.76 | 3.2 | 0.76 | 3.2 | 0,76 | 3,2 |
14 | – | – | – | 0.38 | 2.65 | – | – | – | – | 0,76 | 3,6 |
– | 2.5 | – | – | 0.38 | 2.8 | – | – | – | – | 0,76 | 3,6 |
12 | – | – | – | 0.38 | 3.2 | – | – | – | – | 0,76 | 4 |
– | 4 | – | – | 0.38 | 3.4 | – | – | – | – | 0,76 | 4,2 |
10 | – | – | – | 0.38 | 3.8 | – | – | – | – | – | – |
– | 6 | – | – | 0.38 | 3.9 | – | – | – | – | – | – |
8 | – | – | – | 0.38 | 4.6 | – | – | – | – | – | – |
– | 10 | – | – | 0.38 | 5.2 | – | – | – | – | – | – |
6 | – | – | – | 0.38 | 5.9 | – | – | – | – | – | – |
– | 16 | – | – | 0.38 | 6.3 | – | – | – | – | – | – |
4 | – | – | – | 0.38 | 7.3 | – | – | – | – | – | – |
– | 25 | – | – | 0.38 | 7.8 | – | – | – | – | – | – |
2 | 35 | – | – | 0.38 | 8.9 | – | – | – | – | – | – |
1 | – | – | – | 0.38 | 10.1 | – | – | – | – | – | – |
– | 50 | – | – | 0.38 | 10.5 | – | – | – | – | – | – |
1/0 | – | – | – | 0.38 | 1 1.2 | – | – | – | – | – | – |
2/0 | 70 | – | – | 0.38 | 12.3 | – | – | – | – | – | – |
3/0 | – | – | – | 0.38 | 13.9 | – | – | – | – | – | – |
– | 95 | – | – | 0.38 | 14.1 | – | – | – | – | – | – |
4/0 | – | – | – | 0.38 | 15.5 | – | – | – | – | – | – |
– | 120 | v | – | 0.38 | 15.8 | – | – | – | – | – | – |
Conducting metal | BCD | BCDEFG | BCDEFG | BCDEFG | BCDEG |
Style | 3137 | 3138 | 3529 | 3536 | 3580 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
105 °C -600 V | 105 °C - 600 V | 105 °C -600 V | 105 °C -600 V | 105 °C -600 V(cUL 600V) | |||||||
Nominal cross-section | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | [mm] | [mm] | |||||
26 | 0.13 | 1.14 | 2.8 | – | – | 0.76 | 2.0 | – | – | 1.14 | 2.8 |
24 | 0.22 | 1.14 | 2.9 | – | – | 0.76 | 2.1 | – | – | 1.14 | 2.9 |
22 | 0.34 | 1.14 | 3.05 | – | – | 0.76 | 2.35 | – | – | 1.14 | 3.05 |
– | 0.5 | 1.14 | 3.2 | – | – | 0.76 | 2.5 | 0.76 | 2.5 | 1.14 | 3.2 |
20 | 0.6 | 1.14 | 3.4 | – | – | 0.76 | 2.5 | 0.76 | 2.5 | 1.14 | 3.4 |
– | 0.75 | – | – | – | – | 0.76 | 2.7 | 0.76 | 2.7 | 1.14 | 3.5 |
18 | 0.93 | – | – | 1.14 | 3.6 | 0.76 | 2.8 | 0.76 | 2.8 | 1.14 | 3.6 |
– | 1 | – | – | 1.14 | 3.7 | 0.76 | 2.9 | 0.76 | 2.9 | 1.14 | 3.7 |
16 | 1.34 | – | – | 1.14 | 3.8 | 0.76 | 3.1 | 0.76 | 3.1 | 1.14 | 3.8 |
– | 1.5 | – | – | 1.14 | 4.0 | 0.76 | 3.2 | 0.76 | 3.2 | 1.14 | 4.0 |
14 | – | – | – | 1.14 | 4.3 | 0.76 | 3.5 | 0.76 | 3.5 | 1.14 | 4.3 |
– | 2.5 | – | – | 1.14 | 4.4 | 0.76 | 3.6 | 0.76 | 3.6 | 1.14 | 4.4 |
12 | – | – | – | 1.14 | 4.6 | 0.76 | 4.0 | 0.76 | 4.0 | 1.14 | 4.6 |
– | 4 | – | – | 1.14 | 4.9 | 0.76 | 4.2 | 0.76 | 4.2 | 1.14 | 4.9 |
10 | – | – | – | 1.14 | 5.3 | 1.14 | 5.3 | 1.14 | 5.3 | 1.14 | 5.3 |
– | 6 | – | – | 1.14 | 5.6 | 1.14 | 5.6 | 1.14 | 5.5 | 1.14 | 5.6 |
8 | – | – | – | – | – | 1.52 | 6.8 | 1.52 | 6.8 | 1.52 | 6.8 |
– | 10 | – | – | – | – | 1.52 | 7.5 | 1.52 | 7.6 | 1.52 | 7.4 |
6 | – | – | – | – | – | 1.52 | 8.4 | 1.52 | 8.4 | 1.52 | 8.4 |
– | 16 | – | – | – | – | 1.52 | 9.0 | 1.52 | 9.0 | 1.52 | 9.0 |
4 | – | – | – | – | – | 1.52 | 10.2 | 1.52 | 10.2 | 1.52 | 10.2 |
– | 25 | – | – | – | – | 1.52 | 10.6 | 1.52 | 10.6 | 1.52 | 10.6 |
2 | 35 | – | – | – | – | 1.52 | 11.4 | 1.52 | 11.4 | 1.52 | 11.4 |
1 | – | – | – | – | – | 2.03 | 13.9 | 2.03 | 13.9 | 2.03 | 13.9 |
– | 50 | – | – | – | – | 2.03 | 14.6 | 2.03 | 14.6 | 2.03 | 14.6 |
1/0 | – | – | – | – | – | 2.03 | 15.0 | 2.03 | 15.0 | 2.03 | 15.0 |
2/0 | 70 | – | – | – | – | 2.03 | 15.9 | 2.03 | 15.9 | 2.03 | 15.9 |
3/0 | – | – | – | – | – | 2.03 | 17.6 | 2.03 | 17.6 | 2.03 | 17.6 |
– | 95 | – | – | – | – | 2.03 | 17.8 | 2.03 | 17.8 | 2.03 | 17.8 |
4/0 | – | – | – | – | – | 2.03 | 19.1 | 2.41 | 19.9 | 2.03 | 19.1 |
– | 120 | – | – | – | – | 2.03 | 19.5 | 2.41 | 20.3 | 2.03 | 19.5 |
250MCM | – | – | – | – | – | 2.41 | 20.1 | 2.41 | 20.1 | 2.41 | 20.1 |
– | 150 | – | – | – | – | 2.41 | 20.8 | 2.41 | 20.8 | 2.41 | 20.8 |
300MCM | – | – | – | – | – | 2.41 | 23.0 | 2.41 | 23.0 | 2.41 | 23.0 |
350MCM | 185 | – | – | – | – | 2.41 | 24.0 | 2.41 | 24.0 | 2.41 | 24.0 |
400MCM | – | – | – | – | – | 2.41 | 25.0 | 2.41 | 25.0 | 2.41 | 25.0 |
– | 240 | – | – | – | – | 2.41 | 26.3 | 2.41 | 26.3 | 2.41 | 26.3 |
500MCM | – | – | – | – | – | 2.41 | 27.6 | – | – | 2.41 | 27.6 |
– | 300 | – | – | – | – | 2.79 | 30.1 | – | – | – | – |
600MCM | – | – | – | – | – | 2.79 | 30.7 | – | – | – | – |
700MCM | – | – | – | – | – | 2.79 | 32.6 | – | – | – | – |
750MCM | 400 | – | – | – | – | 2.79 | 33.6 | – | – | – | – |
Conducting metal | BCDEF | BCDEF | BCDEFG | BCDEFG | BCDEFG |
* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.
KEY
Conducting metal
B Tin-plated coppe
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
• Continuous operating temperatures: -60 °C to +150 °C. • All colours including two-coloured. • UL approval as per standard UL 758 - File no.: E101965. • Cabling for household electrical heating appliances, rotating machines, lighting. • Other nominal cross-sections: contact us |
![]() 1 • Bare copper, tin-plated, nickel-plated or silver-plated core. |
Style | 3099 | 3132 | 3123 | 3133 | 3134 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
105 °C -300 V(cUL 600V) | 105 °C - 300 V | 105 °C -600 V | 105 °C -600 V | 105 °C -600 V | |||||||
Nominal cross-section | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | [mm] | [mm] | |||||
26 | 0.13 | – | – | 0.38 | 1.2 | 0.76 | 2.0 | 0.76 | 2.0 | – | – |
24 | 0.22 | – | – | 0.38 | 1.4 | 0.76 | 2.1 | 0.76 | 2.1 | – | – |
22 | 0.34 | – | – | 0.38 | 1.55 | 0.76 | 2.35 | 0.76 | 2.35 | – | – |
– | 0.5 | – | – | 0.38 | 1.7 | 0.76 | 2.5 | 0.76 | 2.5 | – | – |
20 | 0.6 | 0.76 | 2.5 | 0.38 | 1.75 | 0.76 | 2.5 | 0.76 | 2.5 | – | – |
– | 0.75 | 0.76 | 2.7 | 0.38 | 1.9 | 0.76 | 2.7 | 0.76 | 2.7 | – | – |
18 | 0.93 | 0.76 | 2.8 | 0.38 | 2.0 | 0.76 | 2.8 | 0.76 | 2.7 | 0,76 | 2,7 |
– | 1 | 0.76 | 2.9 | 0.38 | 2.1 | 0.76 | 2.8 | 0.76 | 2.8 | 0,76 | 2,9 |
16 | 1.34 | 0.76 | 3.1 | 0.38 | 2.3 | 0.76 | 3.0 | 0.76 | 3.1 | 0,76 | 3,1 |
– | 1.5 | 0.76 | 3.2 | 0.38 | 2.4 | 0.76 | 3.2 | 0.76 | 3.2 | 0,76 | 3,2 |
14 | – | – | – | 0.38 | 2.65 | – | – | – | – | 0,76 | 3,6 |
– | 2.5 | – | – | 0.38 | 2.8 | – | – | – | – | 0,76 | 3,6 |
12 | – | – | – | 0.38 | 3.2 | – | – | – | – | 0,76 | 4 |
– | 4 | – | – | 0.38 | 3.4 | – | – | – | – | 0,76 | 4,2 |
10 | – | – | – | 0.38 | 3.8 | – | – | – | – | – | – |
– | 6 | – | – | 0.38 | 3.9 | – | – | – | – | – | – |
8 | – | – | – | 0.38 | 4.6 | – | – | – | – | – | – |
– | 10 | – | – | 0.38 | 5.2 | – | – | – | – | – | – |
6 | – | – | – | 0.38 | 5.9 | – | – | – | – | – | – |
– | 16 | – | – | 0.38 | 6.3 | – | – | – | – | – | – |
4 | – | – | – | 0.38 | 7.3 | – | – | – | – | – | – |
– | 25 | – | – | 0.38 | 7.8 | – | – | – | – | – | – |
2 | 35 | – | – | 0.38 | 8.9 | – | – | – | – | – | – |
1 | – | – | – | 0.38 | 10.1 | – | – | – | – | – | – |
– | 50 | – | – | 0.38 | 10.5 | – | – | – | – | – | – |
1/0 | – | – | – | 0.38 | 1 1.2 | – | – | – | – | – | – |
2/0 | 70 | – | – | 0.38 | 12.3 | – | – | – | – | – | – |
3/0 | – | – | – | 0.38 | 13.9 | – | – | – | – | – | – |
– | 95 | – | – | 0.38 | 14.1 | – | – | – | – | – | – |
4/0 | – | – | – | 0.38 | 15.5 | – | – | – | – | – | – |
– | 120 | v | – | 0.38 | 15.8 | – | – | – | – | – | – |
Conducting metal | BCD | BCDEFG | BCDEFG | BCDEFG | BCDEG |
Style | 3137 | 3138 | 3529 | 3536 | 3580 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
105 °C -600 V | 105 °C - 600 V | 105 °C -600 V | 105 °C -600 V | 105 °C -600 V(cUL 600V) | |||||||
Nominal cross-section | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | Average thickness of insulation | Nominal diameter* | |
AWG | [mm2] | [mm] | [mm] | [mm] | [mm] | [mm] | |||||
26 | 0.13 | 1.14 | 2.8 | – | – | 0.76 | 2.0 | – | – | 1.14 | 2.8 |
24 | 0.22 | 1.14 | 2.9 | – | – | 0.76 | 2.1 | – | – | 1.14 | 2.9 |
22 | 0.34 | 1.14 | 3.05 | – | – | 0.76 | 2.35 | – | – | 1.14 | 3.05 |
– | 0.5 | 1.14 | 3.2 | – | – | 0.76 | 2.5 | 0.76 | 2.5 | 1.14 | 3.2 |
20 | 0.6 | 1.14 | 3.4 | – | – | 0.76 | 2.5 | 0.76 | 2.5 | 1.14 | 3.4 |
– | 0.75 | – | – | – | – | 0.76 | 2.7 | 0.76 | 2.7 | 1.14 | 3.5 |
18 | 0.93 | – | – | 1.14 | 3.6 | 0.76 | 2.8 | 0.76 | 2.8 | 1.14 | 3.6 |
– | 1 | – | – | 1.14 | 3.7 | 0.76 | 2.9 | 0.76 | 2.9 | 1.14 | 3.7 |
16 | 1.34 | – | – | 1.14 | 3.8 | 0.76 | 3.1 | 0.76 | 3.1 | 1.14 | 3.8 |
– | 1.5 | – | – | 1.14 | 4.0 | 0.76 | 3.2 | 0.76 | 3.2 | 1.14 | 4.0 |
14 | – | – | – | 1.14 | 4.3 | 0.76 | 3.5 | 0.76 | 3.5 | 1.14 | 4.3 |
– | 2.5 | – | – | 1.14 | 4.4 | 0.76 | 3.6 | 0.76 | 3.6 | 1.14 | 4.4 |
12 | – | – | – | 1.14 | 4.6 | 0.76 | 4.0 | 0.76 | 4.0 | 1.14 | 4.6 |
– | 4 | – | – | 1.14 | 4.9 | 0.76 | 4.2 | 0.76 | 4.2 | 1.14 | 4.9 |
10 | – | – | – | 1.14 | 5.3 | 1.14 | 5.3 | 1.14 | 5.3 | 1.14 | 5.3 |
– | 6 | – | – | 1.14 | 5.6 | 1.14 | 5.6 | 1.14 | 5.5 | 1.14 | 5.6 |
8 | – | – | – | – | – | 1.52 | 6.8 | 1.52 | 6.8 | 1.52 | 6.8 |
– | 10 | – | – | – | – | 1.52 | 7.5 | 1.52 | 7.6 | 1.52 | 7.4 |
6 | – | – | – | – | – | 1.52 | 8.4 | 1.52 | 8.4 | 1.52 | 8.4 |
– | 16 | – | – | – | – | 1.52 | 9.0 | 1.52 | 9.0 | 1.52 | 9.0 |
4 | – | – | – | – | – | 1.52 | 10.2 | 1.52 | 10.2 | 1.52 | 10.2 |
– | 25 | – | – | – | – | 1.52 | 10.6 | 1.52 | 10.6 | 1.52 | 10.6 |
2 | 35 | – | – | – | – | 1.52 | 11.4 | 1.52 | 11.4 | 1.52 | 11.4 |
1 | – | – | – | – | – | 2.03 | 13.9 | 2.03 | 13.9 | 2.03 | 13.9 |
– | 50 | – | – | – | – | 2.03 | 14.6 | 2.03 | 14.6 | 2.03 | 14.6 |
1/0 | – | – | – | – | – | 2.03 | 15.0 | 2.03 | 15.0 | 2.03 | 15.0 |
2/0 | 70 | – | – | – | – | 2.03 | 15.9 | 2.03 | 15.9 | 2.03 | 15.9 |
3/0 | – | – | – | – | – | 2.03 | 17.6 | 2.03 | 17.6 | 2.03 | 17.6 |
– | 95 | – | – | – | – | 2.03 | 17.8 | 2.03 | 17.8 | 2.03 | 17.8 |
4/0 | – | – | – | – | – | 2.03 | 19.1 | 2.41 | 19.9 | 2.03 | 19.1 |
– | 120 | – | – | – | – | 2.03 | 19.5 | 2.41 | 20.3 | 2.03 | 19.5 |
250MCM | – | – | – | – | – | 2.41 | 20.1 | 2.41 | 20.1 | 2.41 | 20.1 |
– | 150 | – | – | – | – | 2.41 | 20.8 | 2.41 | 20.8 | 2.41 | 20.8 |
300MCM | – | – | – | – | – | 2.41 | 23.0 | 2.41 | 23.0 | 2.41 | 23.0 |
350MCM | 185 | – | – | – | – | 2.41 | 24.0 | 2.41 | 24.0 | 2.41 | 24.0 |
400MCM | – | – | – | – | – | 2.41 | 25.0 | 2.41 | 25.0 | 2.41 | 25.0 |
– | 240 | – | – | – | – | 2.41 | 26.3 | 2.41 | 26.3 | 2.41 | 26.3 |
500MCM | – | – | – | – | – | 2.41 | 27.6 | – | – | 2.41 | 27.6 |
– | 300 | – | – | – | – | 2.79 | 30.1 | – | – | – | – |
600MCM | – | – | – | – | – | 2.79 | 30.7 | – | – | – | – |
700MCM | – | – | – | – | – | 2.79 | 32.6 | – | – | – | – |
750MCM | 400 | – | – | – | – | 2.79 | 33.6 | – | – | – | – |
Conducting metal | BCDEF | BCDEF | BCDEFG | BCDEFG | BCDEFG |
* The diameter is provided for information purposes as it may vary depending on the stranding of the core. Only the average thickness of insulation should be taken into account.
KEY
Conducting metal
B Tin-plated coppe
B* Tin-plated copper (Ø > 0.38 mm)
C Nickel-plated copper
D Silver-plated copper
E Nickel
F Bare copper
F* Bare copper (Ø > 0.38 mm)
G Nickel-plated copper 27 %
AWM I A Internal wiring, not subject to mechanical abuse
AWM I A/B Internal wiring
AWM II A/B External or Internal wiring
NS Not Specified
VNS Voltage Not Specified
Не удаётся отправить вашу оценку отзыва
Пожаловаться на комментарий
Жалоба отправлена
Не удаётся отправить вашу жалобу
Оставьте свой отзыв
Отзыв отправлен
Не удаётся отправить отзыв