Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографии предназначены только для информационных целей. Посмотреть спецификацию продукта
please use latin characters
The low power switchgear current transformers in SVA100 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU). This solid, cast resin transformer is cost effective and very reliable. For many years ELEQ develops and produces these protection transformers for the switchgear market. The transformers are specially designed for dynamic loads and applicable for the so called self powered relays like Woodward SEG, WIC1 and others.
Rated data
Location | Indoor use |
---|---|
Protection degree | IP20 |
Rated frequency | 50/60Hz |
Insulation class | E (120°C) |
Primary windows suitable to calbe | Ø50mm |
Material | PU i PA6.6 |
Secondart terminals | 4mm2/6mm2 screw connection |
Test winding | 0.288A |
Burden | Contact manufacturer for details |
Current range | Class | Cable diameter | Number |
---|---|---|---|
8-32A | 5P80 | 45mm |
4G2401 |
16-56A | 10P80 | 50mm |
4G2201N |
32-112A | 5P80 | 50mm |
4G2202N |
64-224A | 5P80 | 50mm |
4G2203N |
128-448A | 5P80 | 50mm |
4G2204N |
16-56A | 5P80 | 50mm |
4G2205N |
256-896A | 5P80 | 50mm |
62200 |
Connection diagram
Dimensions
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The low power switchgear current transformers in SVA100 housing is specially designed for application in medium voltage installations as Ring Main Units (RMU). This solid, cast resin transformer is cost effective and very reliable. For many years ELEQ develops and produces these protection transformers for the switchgear market. The transformers are specially designed for dynamic loads and applicable for the so called self powered relays like Woodward SEG, WIC1 and others.
Rated data
Location | Indoor use |
---|---|
Protection degree | IP20 |
Rated frequency | 50/60Hz |
Insulation class | E (120°C) |
Primary windows suitable to calbe | Ø50mm |
Material | PU i PA6.6 |
Secondart terminals | 4mm2/6mm2 screw connection |
Test winding | 0.288A |
Burden | Contact manufacturer for details |
Current range | Class | Cable diameter | Number |
---|---|---|---|
8-32A | 5P80 | 45mm |
4G2401 |
16-56A | 10P80 | 50mm |
4G2201N |
32-112A | 5P80 | 50mm |
4G2202N |
64-224A | 5P80 | 50mm |
4G2203N |
128-448A | 5P80 | 50mm |
4G2204N |
16-56A | 5P80 | 50mm |
4G2205N |
256-896A | 5P80 | 50mm |
62200 |
Connection diagram
Dimensions
Не удаётся отправить вашу оценку отзыва
Пожаловаться на комментарий
Жалоба отправлена
Не удаётся отправить вашу жалобу
Оставьте свой отзыв
Отзыв отправлен
Не удаётся отправить отзыв