The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.
Environmental conditionss | |
This product is designed to be safe under the following conditions: | |
Location | Indoor use |
---|---|
Ambient temperature: | -5°C .. +40°C |
Relative humidity: | 5% .. 85%, non condensing |
Protection degree: | IP20 |
Suitable for: | Cables, bus-bar |
Application conditions | |
Standard: | IEC 60044-1 |
Rated short-time thermal current (lth): | 60 x In/1s |
Continuous thermal current (lth): | 100% |
Rated insulation level: | 0,72/3/-kv |
Rated frequency: | 50/60Hz |
Class of insulation: | E |
Primary current | 30-1000A |
Primary window dimensions: | Ø 60mm |
Secondary terminal: | Screw terminals (max. 2Nm) Wire diameter max. 6mm² solid max 4mm² stranded |
Radio | Class | Burden | Atricle number |
---|---|---|---|
600-250/1/1 | 0.2/10P10 | 5VA | 106530 |
400-150/1/1 | 0.2/5P10 | 5VA | 106531 |
Wiring diagram
Вы заинтересованы в этом продукте? Вам нужна дополнительная информация или индивидуальные расценки?
Вы должны быть зарегистрированы
The SVA150 is specially designed for application in medium voltage installations as Ring Main Units. This cast measuring
transformer is cost effective and very reliable. Multi-core and multi ratio types are available in measuring and protection classes.
Environmental conditionss | |
This product is designed to be safe under the following conditions: | |
Location | Indoor use |
---|---|
Ambient temperature: | -5°C .. +40°C |
Relative humidity: | 5% .. 85%, non condensing |
Protection degree: | IP20 |
Suitable for: | Cables, bus-bar |
Application conditions | |
Standard: | IEC 60044-1 |
Rated short-time thermal current (lth): | 60 x In/1s |
Continuous thermal current (lth): | 100% |
Rated insulation level: | 0,72/3/-kv |
Rated frequency: | 50/60Hz |
Class of insulation: | E |
Primary current | 30-1000A |
Primary window dimensions: | Ø 60mm |
Secondary terminal: | Screw terminals (max. 2Nm) Wire diameter max. 6mm² solid max 4mm² stranded |
Radio | Class | Burden | Atricle number |
---|---|---|---|
600-250/1/1 | 0.2/10P10 | 5VA | 106530 |
400-150/1/1 | 0.2/5P10 | 5VA | 106531 |
Wiring diagram