Морате бити пријављени да
Category
Фотографије су само у информативне сврхе. Погледајте спецификацију производа
please use latin characters
Application
Multi-stage control of the temperature of liquid or gaseous media, e.g., for activating two-stage burners or heating registers.
The SW-200-12 protecting coil is to be used for temperature control of non-aggressive gases in ducts; for temperature control in non-aggressive fluids, use the TH immersion sleeve, and in aggressive fluids, the NTH immersion sleeve.
Technical data
Housing colour: | grey (lower part like RAL 7016, upper part like RAL 7035) |
Sensor material: | Cu |
Capillary length: | 1.5 m |
Ambient temperature: | −15…+55 °C |
Max. sensor temperature | top scale value +15% |
Permissible atmospheric humidity: | Max. 95% rel. humidity, non-condensing |
Operating voltage: | none |
Max. switching current: | 15 (8) A |
Min. switching current: | 150 mA |
Max. switching voltage: | 230 VAC, 50 Hz |
Min. switching voltage: | 24 VAC, 50 Hz |
Switching element: | microswitch |
Switching contact: | 2 x togglers, potential-free |
Control function: | 2-stage heating, 2-stage cooling, heating or cooling with neutral zone |
Hysteresis between the stages: | approx. 1…7 K, adjustable |
Electrical connection: | screw-type terminals |
Mounting/attachment: | wall mounting |
Protection rating: | IP 65 |
Protection class: | I |
Safety and EMC: | according to DIN EN 60730 |
Sensor: | liquid-filled capillary |
General features: | Scale: degrees Celsius |
Type | Item no. | Control range | Hysteresis in thestage (approx.): | Sensor a x l (mm) | Features | PG |
---|---|---|---|---|---|---|
JMT-206 X | E6060340 | 20…80 °C | 1 K | 9.6 x 122 mm | External setting, TR | II |
TR = Temperature controller
Да ли вас занима овај производ? Да ли су вам потребне додатне информације или појединачне цене?
морате бити пријављени
Application
Multi-stage control of the temperature of liquid or gaseous media, e.g., for activating two-stage burners or heating registers.
The SW-200-12 protecting coil is to be used for temperature control of non-aggressive gases in ducts; for temperature control in non-aggressive fluids, use the TH immersion sleeve, and in aggressive fluids, the NTH immersion sleeve.
Technical data
Housing colour: | grey (lower part like RAL 7016, upper part like RAL 7035) |
Sensor material: | Cu |
Capillary length: | 1.5 m |
Ambient temperature: | −15…+55 °C |
Max. sensor temperature | top scale value +15% |
Permissible atmospheric humidity: | Max. 95% rel. humidity, non-condensing |
Operating voltage: | none |
Max. switching current: | 15 (8) A |
Min. switching current: | 150 mA |
Max. switching voltage: | 230 VAC, 50 Hz |
Min. switching voltage: | 24 VAC, 50 Hz |
Switching element: | microswitch |
Switching contact: | 2 x togglers, potential-free |
Control function: | 2-stage heating, 2-stage cooling, heating or cooling with neutral zone |
Hysteresis between the stages: | approx. 1…7 K, adjustable |
Electrical connection: | screw-type terminals |
Mounting/attachment: | wall mounting |
Protection rating: | IP 65 |
Protection class: | I |
Safety and EMC: | according to DIN EN 60730 |
Sensor: | liquid-filled capillary |
General features: | Scale: degrees Celsius |
Type | Item no. | Control range | Hysteresis in thestage (approx.): | Sensor a x l (mm) | Features | PG |
---|---|---|---|---|---|---|
JMT-206 X | E6060340 | 20…80 °C | 1 K | 9.6 x 122 mm | External setting, TR | II |
TR = Temperature controller