

Морате бити пријављени да
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографије су само у информативне сврхе. Погледајте спецификацију производа
please use latin characters
Han-Power® S | ||||
---|---|---|---|---|
Power supply | 1 x Q 4/2 | 1 x Q 4/2 | 2 x Q 4/2 | 1 x Q 8/0 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
25 A 500 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | 10 A 250 V 4 kV | 10 A 250 V 4 kV | - |
Wire gauge | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 4 ... 6 mm2 | 2,5 ... 4 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-7 |
Part number | 09 12 008 4804 | 09 12 008 4806 | 09 12 008 4807 | 09 12 008 4801 |
Power supply | 1 x Q 8/0 | 2 x Q 8/0 | 1 x Q 4/2 | 1 x Q 4/2 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
25 A 500 V 6 kV 3 |
25 A 500 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | - | - | 10 A 250 V 4 kV | 10 A 250 V 4 kV |
Wire gauge | 4 ... 6 mm2 | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 10 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-5 |
Part number | 09 12 008 4811 | 09 12 008 4802 | 09 12 008 4901 | 09 12 008 4951 |
Han-Power®S Akcesoria | ||||||
---|---|---|---|---|---|---|
Identification | Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Zaślepka wkręcana |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Cable diameter | 7 - 10 mm | 10 - 13 mm | 13 - 16 mm | 16 - 19 mm | 19 - 22 mm | |
Bestell-Nummer | 09 12 000 9969 | 09 12 000 9970 | 09 12 000 9971 | 09 12 000 9972 | 09 12 000 9973 | 09 12 000 9974 |
Han-Power® T | |||
---|---|---|---|
Power supply | 3 x Q 4/2 | 3 x Q 5/0 | 3 x Q 3/4 |
Power supply | Crimp terminal | Crimp terminal | Crimp terminal |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
16 A 230/400 V 4 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | - | 16 A 400 V 6 kV |
Wire gauge | 4 ... 6 mm2 | 0,14 ... 2,5 mm2 | 2,5 ... 6 mm2 |
Identification of contacts | 04-sty | 05-sty | 07-sty |
Part number | 09 12 008 4720 | 09 12 008 4751 | 09 12 008 4760 |
Да ли вас занима овај производ? Да ли су вам потребне додатне информације или појединачне цене?
морате бити пријављени
Han-Power® S | ||||
---|---|---|---|---|
Power supply | 1 x Q 4/2 | 1 x Q 4/2 | 2 x Q 4/2 | 1 x Q 8/0 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
25 A 500 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | 10 A 250 V 4 kV | 10 A 250 V 4 kV | - |
Wire gauge | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 4 ... 6 mm2 | 2,5 ... 4 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-7 |
Part number | 09 12 008 4804 | 09 12 008 4806 | 09 12 008 4807 | 09 12 008 4801 |
Power supply | 1 x Q 8/0 | 2 x Q 8/0 | 1 x Q 4/2 | 1 x Q 4/2 |
Power supply | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal | IDC Insulation displacement terminal |
![]() |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
25 A 500 V 6 kV 3 |
25 A 500 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | - | - | 10 A 250 V 4 kV | 10 A 250 V 4 kV |
Wire gauge | 4 ... 6 mm2 | 2,5 ... 4 mm2 | 4 ... 6 mm2 | 10 mm2 |
Identification of contacts | 1-7 | 1-7 | 1-7 | 1-5 |
Part number | 09 12 008 4811 | 09 12 008 4802 | 09 12 008 4901 | 09 12 008 4951 |
Han-Power®S Akcesoria | ||||||
---|---|---|---|---|---|---|
Identification | Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Uszczelnienie przelotu przez panel |
Zaślepka wkręcana |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Cable diameter | 7 - 10 mm | 10 - 13 mm | 13 - 16 mm | 16 - 19 mm | 19 - 22 mm | |
Bestell-Nummer | 09 12 000 9969 | 09 12 000 9970 | 09 12 000 9971 | 09 12 000 9972 | 09 12 000 9973 | 09 12 000 9974 |
Han-Power® T | |||
---|---|---|---|
Power supply | 3 x Q 4/2 | 3 x Q 5/0 | 3 x Q 3/4 |
Power supply | Crimp terminal | Crimp terminal | Crimp terminal |
![]() |
![]() |
![]() |
|
Electrical data acc. to EN 61 984 Power contacts |
40 A 400/690 V 6 kV 3 |
16 A 230/400 V 4 kV 3 |
40 A 400/690 V 6 kV 3 |
Signal contacts | 10 A 250 V 4 kV | - | 16 A 400 V 6 kV |
Wire gauge | 4 ... 6 mm2 | 0,14 ... 2,5 mm2 | 2,5 ... 6 mm2 |
Identification of contacts | 04-sty | 05-sty | 07-sty |
Part number | 09 12 008 4720 | 09 12 008 4751 | 09 12 008 4760 |
Vaša zahvalnost na komentar ne može biti registrovana
Prijavite nepristojan komentar
Prija nepristojnog komentara registrovana
Vaša prijava nepristojnog komentara ne može biti registrovana
Napišite vaš komentar
Komentar poslat
Vaš komentar ne može biti registrovan