Детектори дима

We're offering a wide choice of smoke sensors and detectors for use in automation and industry.

Optical duct smoke detector with service alarm and built-in control unit for duct installation, 24V

Uniguard has been developed to detect smoke in ventilation...

We're offering a wide choice of smoke sensors and detectors for use in automation and industry.

Optical...

Опширније
Прикажи филтере
Сакриј филтереФилтрацијаПрикажи филтере X
Manufacturers
more... less
Напон
more... less
Додатне Информације
more... less
Радна температура
more... less
Капацитет пребацивања
more... less
Filter
Информације close
Products that are marked "On Order" in the "Available Quantity" column are usually not in stock. Such products are available for purchase, however, due to their limited customer base, they usually have higher minimum quantities. DACPOL offers products that are not in stock for the following reasons: DACPOL currently has a large number of electronic components in stock and adds new products every day, however, tens of thousands of additional components and their various variants are available from our suppliers. Even though it is unreasonable to have all these products in stock due to the limited sales, we believe that it is in the best interest of our customers to make them available. Our goal is to inform customers about the maximum number of products available and enable them to make decisions based on specifications, prices, availability, required minimums and our technical advice. Please note that selecting the "In Stock" checkbox may limit the display to only products available for delivery straight from the shelf.
ПДФ Слика
Произвођач
Назив производа
Погледајте производ Не. Произвођач
Количина доступна
Напон
Додатне Информације
Радна температура
Капацитет пребацивања
picture_as_pdf УГ-3-А40 Унигуард Суперфлов Calectro УГ-3-А40 Унигуард Суперфлов ВИДИ ГА -- On Order -- -- -- --
-- УГ-3-А40 Цханнел сензор дима са ал. служба Calectro УГ-3-А40 Цханнел сензор дима са ал. служба ВИДИ ГА UG-3-A40 2 24 V AC / DC +/- 10% bez rurki Venturiego -20 °C ... +50 °C 10 (4) A
-- ВР-0,6М Вентури Тубе 0.6м Calectro ВР-0,6М Вентури Тубе 0.6м ВИДИ ГА VR-0,6M 2 -- dł. 0,6 m -- --
-- ВР-1.5М ВЕНТУРИ ТУБЕ 1.5 М + ХФУ204 гума Calectro ВР-1.5М ВЕНТУРИ ТУБЕ 1.5 М + ХФУ204 гума ВИДИ ГА VR-1,5M 10 -- długość 1,5 m -- --
-- УГ-поклопац заштитни поклопац за УГ-3 Calectro УГ-поклопац заштитни поклопац за УГ-3 ВИДИ ГА UG-COVER 2 -- stal ocynkowana -- --
picture_as_pdf ЕВЦ-ПИ-ДА / и детектор дима у УГ-3-А4О Calectro ЕВЦ-ПИ-ДА / и детектор дима у УГ-3-А4О ВИДИ ГА EVC-PY-DA/I 2 24 V AC / DC +/- 10% Wymienny detektor do UG-3-A4O -20 °C ... +50 °C 10 (4) A
picture_as_pdf Sample tube ST5 Calectro Sample tube ST5 ВИДИ ГА ST5 9 -- -- -- --
picture_as_pdf Sample tube ST9 Calectro Sample tube ST9 ВИДИ ГА ST9 1 -- -- -- --
picture_as_pdf UG-5-AFR-24V Каналски аутономни детектор дима Uniguard Superflow Calectro UG-5-AFR-24V Каналски аутономни детектор дима Uniguard Superflow ВИДИ ГА -- 1 -- -- -- --
Резултати по страни:

We're offering a wide choice of smoke sensors and detectors for use in automation and industry.

Optical duct smoke detector with service alarm and built-in control unit for duct installation, 24V

Uniguard has been developed to detect smoke in ventilation ducts and combines a smoke detector and an adaptor system where both tube and housing are specially designed for optimum airflow through the smoke detector. There is a built-in alarm relay to control fire-safety dampers, stop ventilation fans, or activate acoustic and optical alarms, etc. There is a built-in service alarm relay to let you know when maintenance is needed before a false alarm occurs. 

A smoke sensor/detector is a key device in all houses, apartments, workshops, and factories, in which there's a risk of uncontrolled smoke occurrence. 

Smoke detector - the principle of operation

The smoke sensor monitors air conditioning. In case of detecting danger, that is, a moment in which the norms of a given gas concentration are exceeded, the sensor signals the risk with a sound alarm. 

Smoke detectors should be managed in places where tee smoke can be quickly detected, thus should be placed on the ceiling, in the highest room point. They are not installed in well-ventilated rooms, and also outside the buildings.

Smoke detectors - types

  • Optical smoke sensor - sensor with high sensitivity, works immediately after detecting smoke. For work in closed rooms, where smoke, dust or steam does not normally occur. Based on infrared radiation.
  • Linear smoke detector -  in big surface rooms. Works based on intaking light through the smoke. 
  • Carbon monoxide sensor - in rooms constantly occupied by people. 
  • Ionizing smoke sensor - contains electrodes, between which there's an uninterrupted ion flow. The smoke interrupts the flow and the sensor is activated. 

Applications and functions of smoke sensors and alarm systems:

  • alarming about the fie, information about need for evacuation;
  • turning on sprinklers, turning off air conditioning, cutting off power;
  • informing the fire department.

Benefits of fire sensors: short reaction time, additional function in smoke detection systems.

Disadvantages: false alarms.