

Ви повинні увійти в систему
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографії призначені тільки для інформаційних цілей. Подивитися специфікацію продукту
please use latin characters
Axial fan, ball bearing | service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor plastic |
Connection | 2 wires with pressure clamps 2.5mm², length 100mm |
Casing (filter fan and exit filter) | plastic according to UL94 V-0, light grey |
Mounting frame | with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); a template for the enclosure cut-out is included in the delivery of the filter fans |
Filter mat | G4 acc. to DIN EN 779, filtering degree 94% |
Filter material | synthetic fibre with progressive construction, temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming |
Operating/Storage temperature | - 45°C - +70°C |
Protection class | IP54* /1 (z przewodem ochronnym) |
Special features
|
![]() |
Wentylatory z fltrem montuje się I podłącza od zewnątrz w prosty sposób.
Filter fans are easily installed by one person from outside the cabinet.
1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included in the delivery of the filter fan.
2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. (For size 176mm and up we recommend additional screw fixing.)
3.) Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws.
4.) Insert the filter mat in the hood. Clip on. Finished.
Changing the filter mat or fan is quickly done by one person. To change the filter mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2).
Art. No. | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
Approvals |
---|---|---|---|---|---|---|---|---|---|---|
01800.0-00 |
AC 230 V, 50 Hz | 21 m3/h | 16 m3/h | 80 mA | 13W | 31 dB (A) | 45 mm | 97x97 mm +0,4 | 0,60 kg | VDE+UL File No. E234324 |
01801.0-00 |
AC 230 V, 50 Hz | 55 m3/h | 42 m3/h | 100 mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+0,4 | 1,00 kg | VDE+UL File No. E234324 |
01802.0-00 |
AC 230 V, 50 Hz | 102 m3/h | 68 m3/h | 100 mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+0,4 | 1,30 kg | VDE+UL File No. E234324 |
01800.0-01 |
AC120V, 60Hz* | 21 m3/h | 16 m3/h | 160 mA | 13W | 31 dB (A) | 45 mm | 97x97 mm +0,4 | 0,60 kg | UL File No. E234324 |
01801.0-01 |
AC120V, 60Hz* | 55 m3/h | 42 m3/h | 180 mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+0,4 | 1,00 kg | UL File No. E234324 |
01802.0-01 |
AC120V, 60Hz* | 102 m3/h | 68 m3/h | 180 mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+0,4 | 1,30 kg | UL File No. E234324 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Art. No | Depth in enclosure | Enclosure cut-out | Weight (approx.) | Filter mat | Protection type |
---|---|---|---|---|---|
11800.0-00 |
16 mm | 97 x 97 mm + 0,4 | 0,30 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
11801.0-00 |
16 mm | 125x125 mm+ 0,4 | 0,40 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
11802.0-00 |
16 mm | 176x176 mm+ 0,4 | 0,60 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
Filter mat | 89 x 89 mm | 118x118mm | 168 x 168 mm |
---|---|---|---|
G4 (1 packaging unit = 3 pcs.) | Art. No. 08600.0-00 | Art. No. 08601.0-00 | Art. No. 08602.0-00 |
F5 (1 packaging unit = 3 pcs.) | Art. No. 08603.0-00 | Art. No. 08604.0-00 | Art. No. 08605.0-00 |
Air flow sensor built into the grille protects the toes fan FLTR, eg. Art. No. 21800.0-00 | ![]() |
Art. No. | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption. |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
---|---|---|---|---|---|---|---|---|---|
21800.0-00 |
AC 230 V, 50 Hz | 21 m³/h | 16m³/h | 80 mA | 13W | 31 dB (A) | 45 mm | 97 x 97 mm + 0,4 | 0,60 kg |
21801.0-00 |
AC 230 V, 50 Hz | 55 m³/h | 42 m³/h | 100mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+ 0,4 | 1,00 kg |
21802.0-00 |
AC 230 V, 50 Hz | 102m³/h | 68 mv/h | 100mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+ 0,4 | 1,30 kg |
21800.0-01 |
AC120V, 60 Hz | 21 m³/h | 16m³/h | 160mA | 13W | 31 dB (A) | 45 mm | 97 x 97 mm + 0,4 | 0,60 kg |
21801.0-01 |
AC120V, 60 Hz | 55 m³/h | 42 m³/h | 180mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+ 0,4 | 1,00 kg |
21802.0-01 |
AC120V, 60 Hz | 102 m³/h | 68 m³/h | 180mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+ 0,4 | 1,30 kg |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
Axial fan, ball bearing | service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor plastic |
Connection | 2 wires with pressure clamps 2.5mm², length 100mm |
Casing (filter fan and exit filter) | plastic according to UL94 V-0, light grey |
Mounting frame | with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); a template for the enclosure cut-out is included in the delivery of the filter fans |
Filter mat | G4 acc. to DIN EN 779, filtering degree 94% |
Filter material | synthetic fibre with progressive construction, temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH, reusable - cleaning by washing or vacuuming |
Operating/Storage temperature | - 45°C - +70°C |
Protection class | IP54* /1 (z przewodem ochronnym) |
Special features
|
![]() |
Wentylatory z fltrem montuje się I podłącza od zewnątrz w prosty sposób.
Filter fans are easily installed by one person from outside the cabinet.
1.) Make cut-out in the cabinet wall. The cut edge of the cabinet opening should be free of dirt, filings and grease. A template for the enclosure cut-out is included in the delivery of the filter fan.
2.) Remove protective film from the sealing strips on the mounting frame. Press mounting frame into the cabinet opening. The frame stays permanently in the cabinet. (For size 176mm and up we recommend additional screw fixing.)
3.) Electrically connect the axial fan using the clip connectors. Push the unit into the mounting frame. Fix using screws.
4.) Insert the filter mat in the hood. Clip on. Finished.
Changing the filter mat or fan is quickly done by one person. To change the filter mat simply remove the filter hood, insert the new mat and snap the hood back again. No tools required. Maintenance of the fan can easily be done without removing the mounting frame (2).
Art. No. | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
Approvals |
---|---|---|---|---|---|---|---|---|---|---|
01800.0-00 |
AC 230 V, 50 Hz | 21 m3/h | 16 m3/h | 80 mA | 13W | 31 dB (A) | 45 mm | 97x97 mm +0,4 | 0,60 kg | VDE+UL File No. E234324 |
01801.0-00 |
AC 230 V, 50 Hz | 55 m3/h | 42 m3/h | 100 mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+0,4 | 1,00 kg | VDE+UL File No. E234324 |
01802.0-00 |
AC 230 V, 50 Hz | 102 m3/h | 68 m3/h | 100 mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+0,4 | 1,30 kg | VDE+UL File No. E234324 |
01800.0-01 |
AC120V, 60Hz* | 21 m3/h | 16 m3/h | 160 mA | 13W | 31 dB (A) | 45 mm | 97x97 mm +0,4 | 0,60 kg | UL File No. E234324 |
01801.0-01 |
AC120V, 60Hz* | 55 m3/h | 42 m3/h | 180 mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+0,4 | 1,00 kg | UL File No. E234324 |
01802.0-01 |
AC120V, 60Hz* | 102 m3/h | 68 m3/h | 180 mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+0,4 | 1,30 kg | UL File No. E234324 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Art. No | Depth in enclosure | Enclosure cut-out | Weight (approx.) | Filter mat | Protection type |
---|---|---|---|---|---|
11800.0-00 |
16 mm | 97 x 97 mm + 0,4 | 0,30 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
11801.0-00 |
16 mm | 125x125 mm+ 0,4 | 0,40 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
11802.0-00 |
16 mm | 176x176 mm+ 0,4 | 0,60 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
Filter mat | 89 x 89 mm | 118x118mm | 168 x 168 mm |
---|---|---|---|
G4 (1 packaging unit = 3 pcs.) | Art. No. 08600.0-00 | Art. No. 08601.0-00 | Art. No. 08602.0-00 |
F5 (1 packaging unit = 3 pcs.) | Art. No. 08603.0-00 | Art. No. 08604.0-00 | Art. No. 08605.0-00 |
Air flow sensor built into the grille protects the toes fan FLTR, eg. Art. No. 21800.0-00 | ![]() |
Art. No. | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption. |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
---|---|---|---|---|---|---|---|---|---|
21800.0-00 |
AC 230 V, 50 Hz | 21 m³/h | 16m³/h | 80 mA | 13W | 31 dB (A) | 45 mm | 97 x 97 mm + 0,4 | 0,60 kg |
21801.0-00 |
AC 230 V, 50 Hz | 55 m³/h | 42 m³/h | 100mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+ 0,4 | 1,00 kg |
21802.0-00 |
AC 230 V, 50 Hz | 102m³/h | 68 mv/h | 100mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+ 0,4 | 1,30 kg |
21800.0-01 |
AC120V, 60 Hz | 21 m³/h | 16m³/h | 160mA | 13W | 31 dB (A) | 45 mm | 97 x 97 mm + 0,4 | 0,60 kg |
21801.0-01 |
AC120V, 60 Hz | 55 m³/h | 42 m³/h | 180mA | 15W | 40 dB (A) | 58 mm | 125x125 mm+ 0,4 | 1,00 kg |
21802.0-01 |
AC120V, 60 Hz | 102 m³/h | 68 m³/h | 180mA | 15W | 39 dB (A) | 86 mm | 176x176 mm+ 0,4 | 1,30 kg |
Вашу оцінку відгуку не було надіслано
Поскаржитись на відгук
Скаргу надіслано
Ваш відгук не надіслано
Написати свій відгук
Відгук надіслано
Ваш відгук не надіслано