The cast resin outdoor current transformer is capable to withstanding the outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The primary current is connected with an internal bus bar. The secondary windings are used for measurement and / or protection purposes, or optional with test winding
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ASCI C 57.13; BS 1675 |
Class of insulation | B |
Ith | 100 x IN (max.100kA) |
Idyn: | 2,5 x ITh (max. 125kA) |
Frequency : | 50Hz, 60Hz other frequency on request |
Rated insulation voltage | complying with the standard |
Secondary current | 1A; 5A; other current on request |
Burde / Class: | depending from number of cores accu-racy limit factors and the rated output |
Secondary terminal box: | with degree of protection IP64 Base |
Special model: | Secondary switch-over |
Type |
IGHF 12B 300 |
IGHF 24B 300 |
IGHF 36B 300 |
---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn[A] | 3000 | 3000 | 3000 |
Creepage distance [mm] | 409 | 480 | 1124 |
Max. number of cores | 4 | 5 | 5 |
Number of rips | 3 | 4 | 10 |
Weight [kg] | 46 | 48 | 56 |
Type | A | B | C | D | Sec. Terminals | Rippen |
---|---|---|---|---|---|---|
IGHF 12 |
300 | 300 | 350 | 500 | 8 | 3 |
IGHF 24 |
300 | 300 | 395 | 545 | 10 | 4 |
IGHF 36 |
300 | 300 | 542 | 692 | 10 | 10 |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
The cast resin outdoor current transformer is capable to withstanding the outdoor environmental condition. The current transformer is maintenance-free and only mountable in vertical situation. The primary current is connected with an internal bus bar. The secondary windings are used for measurement and / or protection purposes, or optional with test winding
Design | Cast-resin insulated |
---|---|
Colour | brown |
In accordance to | VDE 0414; IEC 60044; ASCI C 57.13; BS 1675 |
Class of insulation | B |
Ith | 100 x IN (max.100kA) |
Idyn: | 2,5 x ITh (max. 125kA) |
Frequency : | 50Hz, 60Hz other frequency on request |
Rated insulation voltage | complying with the standard |
Secondary current | 1A; 5A; other current on request |
Burde / Class: | depending from number of cores accu-racy limit factors and the rated output |
Secondary terminal box: | with degree of protection IP64 Base |
Special model: | Secondary switch-over |
Type |
IGHF 12B 300 |
IGHF 24B 300 |
IGHF 36B 300 |
---|---|---|---|
Insulation voltage [kV] | 12/28/75 | 24/50/125 | 36/70/170 |
Max. Ipn[A] | 3000 | 3000 | 3000 |
Creepage distance [mm] | 409 | 480 | 1124 |
Max. number of cores | 4 | 5 | 5 |
Number of rips | 3 | 4 | 10 |
Weight [kg] | 46 | 48 | 56 |
Type | A | B | C | D | Sec. Terminals | Rippen |
---|---|---|---|---|---|---|
IGHF 12 |
300 | 300 | 350 | 500 | 8 | 3 |
IGHF 24 |
300 | 300 | 395 | 545 | 10 | 4 |
IGHF 36 |
300 | 300 | 542 | 692 | 10 | 10 |