Ви повинні увійти в систему
Category
Фотографії призначені тільки для інформаційних цілей. Подивитися специфікацію продукту
please use latin characters
Technical data
Display | backlit LCD |
---|---|
Max .indcation | digits (9999) |
Decimal point position | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5 sec |
Basic accuracy | +/- 0,2% |
Nominal input voltage Un | 600V |
Nominal input current In | 60mV |
Input range | 10-120% Un, 5-120% In |
Continuous overload | 2xIn; 1,2xUn |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption I | < 0.5VA |
Voltage circuits consumption U | < 0.5VA |
Power supply | 80-260V ac/dc |
Power consumption | 6VA |
Operating temperature | 0 …+23… +50°C |
Storage temperature | -30…+70°C |
Thermoplastic material | UL 94V0 |
Protection for housing | IP52 |
Protection for terminals | IP20 |
Galvanic insulation | aux.supply/inputs/out |
Test voltage | 2kV, 50Hz, 60sec. |
TYPE | Q72C33LX60M.. |
---|
Comunication protocols | Standard | Option |
---|---|---|
ModBus RTU | + | |
Ethernet-ModBus TCP/Webserver | + | |
Johnson Controls N2 OPEN | + | |
Profibus DP v0 | + |
DESCRIPTION
Compact multifunction analyzer for use in DC systems (measures and functions as per the table on page 3) The voltage input is directly wired to the line, while the input proportional to the current, is derived from shunt. Through a simple programming menu is possible to set the value of the primary current, and its insertion on the positive or negative polarity. The wide range of FRER shunt is available in the general catalog (from pag.11.93 to 11.95) and on the web at the www.frer.it site.
ORDERING CODE
Wiring diagrams
![]() |
![]() |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
Technical data
Display | backlit LCD |
---|---|
Max .indcation | digits (9999) |
Decimal point position | Automatic |
Adjustable backlight | 5 levels |
Readings update | <0.5 sec |
Basic accuracy | +/- 0,2% |
Nominal input voltage Un | 600V |
Nominal input current In | 60mV |
Input range | 10-120% Un, 5-120% In |
Continuous overload | 2xIn; 1,2xUn |
Short-term overload | 20 x In; 2 x Un (300 msec.) |
Current circuits consumption I | < 0.5VA |
Voltage circuits consumption U | < 0.5VA |
Power supply | 80-260V ac/dc |
Power consumption | 6VA |
Operating temperature | 0 …+23… +50°C |
Storage temperature | -30…+70°C |
Thermoplastic material | UL 94V0 |
Protection for housing | IP52 |
Protection for terminals | IP20 |
Galvanic insulation | aux.supply/inputs/out |
Test voltage | 2kV, 50Hz, 60sec. |
TYPE | Q72C33LX60M.. |
---|
Comunication protocols | Standard | Option |
---|---|---|
ModBus RTU | + | |
Ethernet-ModBus TCP/Webserver | + | |
Johnson Controls N2 OPEN | + | |
Profibus DP v0 | + |
DESCRIPTION
Compact multifunction analyzer for use in DC systems (measures and functions as per the table on page 3) The voltage input is directly wired to the line, while the input proportional to the current, is derived from shunt. Through a simple programming menu is possible to set the value of the primary current, and its insertion on the positive or negative polarity. The wide range of FRER shunt is available in the general catalog (from pag.11.93 to 11.95) and on the web at the www.frer.it site.
ORDERING CODE
Wiring diagrams
![]() |
![]() |