EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or AC current. These meters measure the true RMS value and their indications are highly independent of the measured value curve shape.
EA16, EA17, EA19 and EA12 meters are designed for mounting into panels. EB16 meters are adapted for a fast assembly rail mounting (35 mm rail) in compliance with EN 60715 standards.
EA16, EA17 and EA19 meters are designed to interchangeable dials.
Accuracy class | 1.5 |
Measured value frequency | 40...45...65...72 Hz |
Execution of ammeters | normal scale version or version with 100% overload. Other overcurrent scale, on request after agreement. |
Self-consumption | see table 1 |
Matching the measurement range of the meter to transformer ranges | by exchange of the dial. The dial is put forward the slot in upper case side. Note: EA12 (144 x 144) meters are not provided for interchangeable dials |
Additional errors according to the standard |
PN-EN 60051-2 |
CATEGORIES OF METER CLIMATIC VERSIONS
If it is not written otherwise in the order, these meters are intended to use in moderate climatic conditions. Then, we do not place any symbol on the scale. On customers’ request, meters can be adapted to use in conditions of a dry or wet tropical climat. Then, they are marked with the T III symbol.
EA17 and EA19 meters (ammeters and voltmeters) destined to be used in ambient temperature up to 75°C or higher, are only available after a previous agreement with the manufacturer.
Requirements concerning safety acc.EN 61010-1 standard:
For EA16 and EB16 meters and meters with rectifiers: | |
- maximal phase-earth working voltage | 600V |
- installation category | 2 |
- pollution degree | 2 |
- maximal phase-earth working voltage | 600 V |
- installation category | III |
- pollution degree | 2 |
- in standard option | IP 50 for EA16, EA17, EA19, EA12 meters | |
IP 54 (only for EA12 meter) | ||
IP 52 (only for EB16 meter) | ||
- with IP 65 front protection grade (on request): | for EA16, EA17, EA19 meters | |
-IP 20 terminal protection (with a terminal protective cover) |
Case material | thermoplastic material |
Meter glass material | glass |
Additional setting pointer | On customers’ request EA17 and EA19 meters can be equiped with an additional setting red pointer fixed in the glass. |
ACCESSORIES | |
We deliver with the meter: | |
- screw holders (for IP50 or IP54 option) | 2 pcs |
- screw holders (for IP65 option) | 4 pcs |
- spring holders (only for EA16) | 2 pcs |
- terminal protection cover | 1 pc |
We can also deliver on request, current and voltage transformers |
Frontal frame dimensions [mm] | 48 x 48*) | 72 x 72 | 96 x 96 | 144 x 144 |
---|---|---|---|---|
Scale length [mm] | 42 | 61 | 95 | 160 |
Weight [kg] | 15 | 2 | 25 | 4 |
Type | EA16, EB16 | EA17 | EA19 | EA12 |
Measuring range | Self-consumption ± 10% | |||
100 mA | 0.43 VA | 0.20 VA | 0.20 VA | 0.48 VA |
150 mA | 0.46 VA | 0.37 VA | 0.37 VA | 0.46 VA |
250 mA | 0.44 VA | 0.31 VA | 0.31 VA | 0.38 VA |
400 mA | 0.43 VA | 0.40 VA | 0.40 VA | 0.48 VA |
600 mA | 0.42 VA | 0.38 VA | 0.38 VA | 0.46 VA |
1 A | 0.45 VA | 0.31 VA | 0.31 VA | 0.38 VA |
1,5 A | 0.47 VA | 0.37 VA | 0.37 VA | 0.45 VA |
2,5 A | 0.44 VA | 0.33 VA | 0.33 VA | 0.40 VA |
4 A | 0.45 VA | 0.30 VA | 0.30 VA | 0.36 VA |
6 A | 0.58 VA | 0.44 VA | 0.44 VA | 0.56 VA |
10 A | 0.55 VA | 0.44 VA | 0.44 VA | 0.55 VA |
15 A | 0.65 VA | 0.60 VA | 0.60 VA | 0.65 VA |
25 A | 0.58 VA | 0.60 VA | 0.60 VA | 0.70 VA |
40 A | – | 0.85 VA | 0.85 VA | 0.85 VA |
60 A | – | 1.20 VA | 1.20 VA | 1.20 VA |
100 A | – | 1.90 VA | 1.90 VA | 1.90 VA |
For a transformer. Measuring ranges acc. table 2 | ||||
... x/1 A | 0.45 VA | 0.31 VA | 0.31 VA | 0.38VA |
... x/5 A | 0.48VA | 0.36 VA | 0.36 VA> | 0.44 VA |
6 V | 2.1 VA | 1.40 VA | 1.40 VA | 1.30 VA |
10 V | 2.2 VA | 1.60 VA | 1.60 VA | 1.50 VA |
15 V | 2.0 VA | 1.80 VA | 1.80 VA | 1.70 VA |
25 V | 2.3 VA | 2.00 VA | 2.00 VA | 1.90 VA |
40 V | 2.3 VA | 1.70 VA | 1.70 VA | 1.60 VA |
60 V | 2.4 VA | 2.10 VA | 2.10 VA | 2.00 VA |
100 V | 2.6 VA | 2.20 VA | 2.20 VA | 2.10 VA |
150 V | 2.5 VA | 2.20 VA | 2.20 VA | 2.10 VA |
250 V | 2.1 VA | 2.40 VA | 2.40 VA | 2.20 VA |
400 V | 2.2 VA | 2.40 VA | 2.40 VA | 2.30 VA |
500 V | 2.8 VA | 2.90 VA | 2.90 VA | 2.80 VA |
600 V | 3.0 VA | 2.30 VA | 2.30 VA | 2.20 VA |
800 V | – | 1.90 VA | 1.90 VA | 1.80 VA |
1000 V | – | 2.40 VA | 2.40 VA | 2.30 VA |
For a transformer. Measuring ranges acc. table 2 | ||||
.../100 V | 2.20 VA | 2.20 VA | 2.10 VA | |
.../110 V | 2.40 VA | 2.40 VA | 2.30 VA |
MEASURING RANGES WITH MEASURING TRANSFORMERSH
Ammeters | Voltmeters | |||
---|---|---|---|---|
Measuring range | Transformer | Measuring range | Transformer | |
1 A | – | 1/1 | 4 kV | 3000/100 V |
5 A | 5/5 | 5/1 | 6 kV | 6000/100 V |
6 A | 6/5 | 6/1 | 10 kV | 10 000/100 V |
6 A | 5/5 | – | 15 kV | 15 000/100 V |
10 A | 10/5 | 10/1 | 20 kV | 20 000/100 V |
15 A | 15/5 | 15/1 | 40 kV | 30 000/100 V |
20 A | 20/5 | 20/1 | 60 kV | 60 000/100 V |
30 A | 30/5 | 30/1 | 150 kV | 150 000/100 V |
40 A | 40/5 | 40/1 | 250 kV | 250 000/100 V |
50 A | 50/5 | 50/1 | 400 kV | 400 000/100 V |
60 A | 60/5 | 60/1 | ||
80 A | 75/5 | – | 4 kV | 4000/100 V |
100 A | 100/5 | 100/1 | 8 kV | 6000/100 V |
150 A | 150/5 | 150/1 | 20 kV | 15 000/100 V |
200 A | 200/5 | 200/1 | 150 kV | 110 000/100 V |
300 A | 300/5 | 300/1 | 250 kV | 220 000/100 V |
400 A | 400/5 | 400/1 | ||
500 A | 500/5 | 500/1 | ||
600 A | 600/5 | 600/1 | ||
800 A | 800/5 | – | ||
1 kA | 1000/5 | 1000/1 | ||
1,2 kA | 1200/5 | 1200/1 | ||
1,5 kA | 1500/5 | 1500/1 | ||
2 kA | 2000/5 | 2000/1 | ||
3 kA | 3000/5 | 3000/1 | ||
4 kA | 4000/5 | 4000/1 | ||
5 kA | 5000/5 | 5000/1 | ||
6 kA | 6000/5 | 6000/1 | ||
8 kA | 8000/5 | 8000/1 | ||
10 kA | 10 000/5 | 10000/1 |
External dimensions
Fig.1. External dimensions of EB16 meters.
Fig.2. External dimensions of EA16 meters
a) with screw holders,
b) with spring holders
Type | a | b | c | d | e | f | g | k |
---|---|---|---|---|---|---|---|---|
mm | ||||||||
EA17 | 72 | 4 | 68-0.3 | 5 | 45 | 10... 20 | 20.5 | 68+0.7 |
EA19 | 96 | 4 | 92-0.3 | 5 | 45 | 10... 20 | 32.5 | 92+0.8 |
EA12 | 144 | 4.5 | 137.3-0.5 | 6 | 48 | 10... 20 | 55.5 | 138+1.0 |
Fig.3. External dimensions of EA17, EA19, EA12 meters
![]() |
![]() |
|||||||||||||||
|
Fig.4. External dimensions of meters with IP65 protection grade
Code | Working position |
---|---|
0 | c3 α = 90° |
A | c1 α = 0° |
B | c2, α = 15° |
C | c2, α = 30° |
D | c2, α = 45° |
E | c2, α = 60° |
F | c2, α = 75° |
H | c4, α = 105° |
I | c4, α = 120° |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or AC current. These meters measure the true RMS value and their indications are highly independent of the measured value curve shape.
EA16, EA17, EA19 and EA12 meters are designed for mounting into panels. EB16 meters are adapted for a fast assembly rail mounting (35 mm rail) in compliance with EN 60715 standards.
EA16, EA17 and EA19 meters are designed to interchangeable dials.
Accuracy class | 1.5 |
Measured value frequency | 40...45...65...72 Hz |
Execution of ammeters | normal scale version or version with 100% overload. Other overcurrent scale, on request after agreement. |
Self-consumption | see table 1 |
Matching the measurement range of the meter to transformer ranges | by exchange of the dial. The dial is put forward the slot in upper case side. Note: EA12 (144 x 144) meters are not provided for interchangeable dials |
Additional errors according to the standard |
PN-EN 60051-2 |
CATEGORIES OF METER CLIMATIC VERSIONS
If it is not written otherwise in the order, these meters are intended to use in moderate climatic conditions. Then, we do not place any symbol on the scale. On customers’ request, meters can be adapted to use in conditions of a dry or wet tropical climat. Then, they are marked with the T III symbol.
EA17 and EA19 meters (ammeters and voltmeters) destined to be used in ambient temperature up to 75°C or higher, are only available after a previous agreement with the manufacturer.
Requirements concerning safety acc.EN 61010-1 standard:
For EA16 and EB16 meters and meters with rectifiers: | |
- maximal phase-earth working voltage | 600V |
- installation category | 2 |
- pollution degree | 2 |
- maximal phase-earth working voltage | 600 V |
- installation category | III |
- pollution degree | 2 |
- in standard option | IP 50 for EA16, EA17, EA19, EA12 meters | |
IP 54 (only for EA12 meter) | ||
IP 52 (only for EB16 meter) | ||
- with IP 65 front protection grade (on request): | for EA16, EA17, EA19 meters | |
-IP 20 terminal protection (with a terminal protective cover) |
Case material | thermoplastic material |
Meter glass material | glass |
Additional setting pointer | On customers’ request EA17 and EA19 meters can be equiped with an additional setting red pointer fixed in the glass. |
ACCESSORIES | |
We deliver with the meter: | |
- screw holders (for IP50 or IP54 option) | 2 pcs |
- screw holders (for IP65 option) | 4 pcs |
- spring holders (only for EA16) | 2 pcs |
- terminal protection cover | 1 pc |
We can also deliver on request, current and voltage transformers |
Frontal frame dimensions [mm] | 48 x 48*) | 72 x 72 | 96 x 96 | 144 x 144 |
---|---|---|---|---|
Scale length [mm] | 42 | 61 | 95 | 160 |
Weight [kg] | 15 | 2 | 25 | 4 |
Type | EA16, EB16 | EA17 | EA19 | EA12 |
Measuring range | Self-consumption ± 10% | |||
100 mA | 0.43 VA | 0.20 VA | 0.20 VA | 0.48 VA |
150 mA | 0.46 VA | 0.37 VA | 0.37 VA | 0.46 VA |
250 mA | 0.44 VA | 0.31 VA | 0.31 VA | 0.38 VA |
400 mA | 0.43 VA | 0.40 VA | 0.40 VA | 0.48 VA |
600 mA | 0.42 VA | 0.38 VA | 0.38 VA | 0.46 VA |
1 A | 0.45 VA | 0.31 VA | 0.31 VA | 0.38 VA |
1,5 A | 0.47 VA | 0.37 VA | 0.37 VA | 0.45 VA |
2,5 A | 0.44 VA | 0.33 VA | 0.33 VA | 0.40 VA |
4 A | 0.45 VA | 0.30 VA | 0.30 VA | 0.36 VA |
6 A | 0.58 VA | 0.44 VA | 0.44 VA | 0.56 VA |
10 A | 0.55 VA | 0.44 VA | 0.44 VA | 0.55 VA |
15 A | 0.65 VA | 0.60 VA | 0.60 VA | 0.65 VA |
25 A | 0.58 VA | 0.60 VA | 0.60 VA | 0.70 VA |
40 A | – | 0.85 VA | 0.85 VA | 0.85 VA |
60 A | – | 1.20 VA | 1.20 VA | 1.20 VA |
100 A | – | 1.90 VA | 1.90 VA | 1.90 VA |
For a transformer. Measuring ranges acc. table 2 | ||||
... x/1 A | 0.45 VA | 0.31 VA | 0.31 VA | 0.38VA |
... x/5 A | 0.48VA | 0.36 VA | 0.36 VA> | 0.44 VA |
6 V | 2.1 VA | 1.40 VA | 1.40 VA | 1.30 VA |
10 V | 2.2 VA | 1.60 VA | 1.60 VA | 1.50 VA |
15 V | 2.0 VA | 1.80 VA | 1.80 VA | 1.70 VA |
25 V | 2.3 VA | 2.00 VA | 2.00 VA | 1.90 VA |
40 V | 2.3 VA | 1.70 VA | 1.70 VA | 1.60 VA |
60 V | 2.4 VA | 2.10 VA | 2.10 VA | 2.00 VA |
100 V | 2.6 VA | 2.20 VA | 2.20 VA | 2.10 VA |
150 V | 2.5 VA | 2.20 VA | 2.20 VA | 2.10 VA |
250 V | 2.1 VA | 2.40 VA | 2.40 VA | 2.20 VA |
400 V | 2.2 VA | 2.40 VA | 2.40 VA | 2.30 VA |
500 V | 2.8 VA | 2.90 VA | 2.90 VA | 2.80 VA |
600 V | 3.0 VA | 2.30 VA | 2.30 VA | 2.20 VA |
800 V | – | 1.90 VA | 1.90 VA | 1.80 VA |
1000 V | – | 2.40 VA | 2.40 VA | 2.30 VA |
For a transformer. Measuring ranges acc. table 2 | ||||
.../100 V | 2.20 VA | 2.20 VA | 2.10 VA | |
.../110 V | 2.40 VA | 2.40 VA | 2.30 VA |
MEASURING RANGES WITH MEASURING TRANSFORMERSH
Ammeters | Voltmeters | |||
---|---|---|---|---|
Measuring range | Transformer | Measuring range | Transformer | |
1 A | – | 1/1 | 4 kV | 3000/100 V |
5 A | 5/5 | 5/1 | 6 kV | 6000/100 V |
6 A | 6/5 | 6/1 | 10 kV | 10 000/100 V |
6 A | 5/5 | – | 15 kV | 15 000/100 V |
10 A | 10/5 | 10/1 | 20 kV | 20 000/100 V |
15 A | 15/5 | 15/1 | 40 kV | 30 000/100 V |
20 A | 20/5 | 20/1 | 60 kV | 60 000/100 V |
30 A | 30/5 | 30/1 | 150 kV | 150 000/100 V |
40 A | 40/5 | 40/1 | 250 kV | 250 000/100 V |
50 A | 50/5 | 50/1 | 400 kV | 400 000/100 V |
60 A | 60/5 | 60/1 | ||
80 A | 75/5 | – | 4 kV | 4000/100 V |
100 A | 100/5 | 100/1 | 8 kV | 6000/100 V |
150 A | 150/5 | 150/1 | 20 kV | 15 000/100 V |
200 A | 200/5 | 200/1 | 150 kV | 110 000/100 V |
300 A | 300/5 | 300/1 | 250 kV | 220 000/100 V |
400 A | 400/5 | 400/1 | ||
500 A | 500/5 | 500/1 | ||
600 A | 600/5 | 600/1 | ||
800 A | 800/5 | – | ||
1 kA | 1000/5 | 1000/1 | ||
1,2 kA | 1200/5 | 1200/1 | ||
1,5 kA | 1500/5 | 1500/1 | ||
2 kA | 2000/5 | 2000/1 | ||
3 kA | 3000/5 | 3000/1 | ||
4 kA | 4000/5 | 4000/1 | ||
5 kA | 5000/5 | 5000/1 | ||
6 kA | 6000/5 | 6000/1 | ||
8 kA | 8000/5 | 8000/1 | ||
10 kA | 10 000/5 | 10000/1 |
External dimensions
Fig.1. External dimensions of EB16 meters.
Fig.2. External dimensions of EA16 meters
a) with screw holders,
b) with spring holders
Type | a | b | c | d | e | f | g | k |
---|---|---|---|---|---|---|---|---|
mm | ||||||||
EA17 | 72 | 4 | 68-0.3 | 5 | 45 | 10... 20 | 20.5 | 68+0.7 |
EA19 | 96 | 4 | 92-0.3 | 5 | 45 | 10... 20 | 32.5 | 92+0.8 |
EA12 | 144 | 4.5 | 137.3-0.5 | 6 | 48 | 10... 20 | 55.5 | 138+1.0 |
Fig.3. External dimensions of EA17, EA19, EA12 meters
![]() |
![]() |
|||||||||||||||
|
Fig.4. External dimensions of meters with IP65 protection grade
Code | Working position |
---|---|
0 | c3 α = 90° |
A | c1 α = 0° |
B | c2, α = 15° |
C | c2, α = 30° |
D | c2, α = 45° |
E | c2, α = 60° |
F | c2, α = 75° |
H | c4, α = 105° |
I | c4, α = 120° |