True RMS Clamp/DMM with infrared thermometer and Bluetooth METERLiNK®
This meter is supplied in the METERLiNK® kit and includes a Bluetooth module designed for use with FLIR infrared cameras. The combination of a clamp meter and an infrared (IR) camera is used for electrical power measurement, analysis, and documentation..
The FLIR CM78 measurement functions include AC/DC voltage , AC/DC current, resistance, capacitance, frequency , diode test, continuity , type k thermocouple temperature plus non-contact IR temperature
Proper use and care of this meter will provide many years of reliable service.
Key features
Meter parts
Front view
Technical specifications
General specifications
Display | 4000-count with bar |
---|---|
Controls | • 8-position rotary switch • Dedicated IR button • 8 dedicated function buttons: flashlight, IR, maximum/minimum, Bluetooth, hold, range, mode, peak |
Backlight | White LED |
Work light | White LED array |
Measurement ranges | See section Electrical range specifications |
Sample rate | 20 per second, nominal |
Input impedance | 10 MΩ (VDC an VAC) |
AC voltage bandwidth | 45–400 Hz |
Power supply | 6 xi AAA (LR03) batteries |
Battery lifte | 100 hours, using alkaline batteries |
Auto power off (APO) | After 25 minutes (nominal) inactivity; reset when the rotary switch is set to OFF, then set to any posistion again |
APO quiescent current | 50 µA maximum |
Over-current protection fuse | No fuse |
Measurement type | True RMS, crest factor ≤ 3 at full scale up to 500 V, decreasing linearly to ≤ 1,5 at 1000 V |
Continuity test | Visual and audible.Threshold is 30 Ω |
Other indications | Low battery, over-range, IR, memory |
Operating temperature | -10 do 50℃ (14 do 122℉) |
Storage temperature | -25 do 60℃ (-14 do 140℉) |
Operating humidity | Maximum 90% up to 35℃ (95℉) decreasing linearly to 60% at 45℃ (113℉) |
Storage humidity | 90% maximum |
Dimensions | 257 mm × 110 mm × 50 mm (10.1″ × 4.3″ × 2.0″) |
Weight | 0,63 kg |
Bluetooth range | 10m (32ft) maximum |
Safety Category Rating | CAT IV-600V, CAT III-1000V |
Electrical range specifications
Valid for ambient temperature conditions 18 to 28 ℃
Function | Range | Resolution | Accuracy (of reading) |
---|---|---|---|
AC current | 400,0 A | 0,1 A | ± (2,5% + 8 digits) |
1000 A | ± (2,8% + 5 digits) | ||
DC current | 400,0 A | 0,1 A | ± (2,5% + 5 digits) |
1000 A | ± (2,8% + 5 digits) | ||
AC voltage | 400,0 mV | 0,1 mV | ± (1,5% + 10 digits) |
4,000 V | 0,001 V | ± (1,5% + 5 digits) | |
40,00 V | 0,01 V | ||
400,0 V | 0,1 V | ||
1000 V | 1 V | ± (2,0% + 5 digits) | |
NOTE |
|||
DC voltage | 400,0 mV | 0,1 mV | ± (1,5%+10 digits) |
4,000 V | 0,001 V | ± (1,5% + 2 digits) | |
40,00 V | 0,01 V | ||
400,0 V | 0,1 V | ||
1000 V | 1 V | ± (2,0% + 2 digits) | |
Resistance | 400,0 Ω | 0,1 Ω | ± (1,0% + 4 digits) |
4,000 kΩ | 0,001 kΩ | ± (1,5% + 2 digits) | |
40,00 kΩ | 0,01 kΩ | ||
400,0 kΩ | 0,1 kΩ | ||
4,000 MΩ | 0,001 MΩ | ± (2,5% + 3 digits) | |
40,00 MΩ | 0,01 MΩ | ± (3,5% + 5 digits) | |
Capacitance | 4,000 nF | 0,001 nF | ± (5,0% + 30 digits) |
40,00 nF | 0,01 nF | ± (5,0% + 20 digits) | |
400,0 nF | 0,1 nF | ± (3,0% + 5 digits) | |
4,000 μF | 0,001 μF | ||
40,00 μF | 0,01 μF | ||
400,0 μF | 0,1 μF | ± (4,0% + 10 digits) | |
4,000 mF | 0,001 mF | ± (10% + 10 digits) | |
40,00 mF | 0,01 mF | Unspecified | |
Frequency | 4,000 kHz | 0,001 kHz | ± (1,5% + 2 digits) |
Sensitivity:: 100 V (< 50 Hz); 50 V (50–400 Hz); 5 V (401–4000 Hz) |
Thermal range specifications
Function | Thermocouple range |
IR range | Accuracy (of reading) |
---|---|---|---|
IR temperature (8:1 ratio) |
-29 do -20℃(-20 do -4℉) | ± 5℃ | |
Od -20 do 270℃ | ±2.0% reading or ±2℃ (±4℉) (whichever is greater) |
||
Type K inputs (excluding probe) |
Od -20 do+120℃ | ±(3% rdg + 5℃) (±(3% rdg + 9℉) |
Maximumu input specifications
Function | Maximum input |
---|---|
AC voltage, DC voltage | 1000 V DC/AC |
Thermocouple | 1000 V DC/AC |
Resistance, capacitance, frequency, diode test | 1000 V DC/AC |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
True RMS Clamp/DMM with infrared thermometer and Bluetooth METERLiNK®
This meter is supplied in the METERLiNK® kit and includes a Bluetooth module designed for use with FLIR infrared cameras. The combination of a clamp meter and an infrared (IR) camera is used for electrical power measurement, analysis, and documentation..
The FLIR CM78 measurement functions include AC/DC voltage , AC/DC current, resistance, capacitance, frequency , diode test, continuity , type k thermocouple temperature plus non-contact IR temperature
Proper use and care of this meter will provide many years of reliable service.
Key features
Meter parts
Front view
Technical specifications
General specifications
Display | 4000-count with bar |
---|---|
Controls | • 8-position rotary switch • Dedicated IR button • 8 dedicated function buttons: flashlight, IR, maximum/minimum, Bluetooth, hold, range, mode, peak |
Backlight | White LED |
Work light | White LED array |
Measurement ranges | See section Electrical range specifications |
Sample rate | 20 per second, nominal |
Input impedance | 10 MΩ (VDC an VAC) |
AC voltage bandwidth | 45–400 Hz |
Power supply | 6 xi AAA (LR03) batteries |
Battery lifte | 100 hours, using alkaline batteries |
Auto power off (APO) | After 25 minutes (nominal) inactivity; reset when the rotary switch is set to OFF, then set to any posistion again |
APO quiescent current | 50 µA maximum |
Over-current protection fuse | No fuse |
Measurement type | True RMS, crest factor ≤ 3 at full scale up to 500 V, decreasing linearly to ≤ 1,5 at 1000 V |
Continuity test | Visual and audible.Threshold is 30 Ω |
Other indications | Low battery, over-range, IR, memory |
Operating temperature | -10 do 50℃ (14 do 122℉) |
Storage temperature | -25 do 60℃ (-14 do 140℉) |
Operating humidity | Maximum 90% up to 35℃ (95℉) decreasing linearly to 60% at 45℃ (113℉) |
Storage humidity | 90% maximum |
Dimensions | 257 mm × 110 mm × 50 mm (10.1″ × 4.3″ × 2.0″) |
Weight | 0,63 kg |
Bluetooth range | 10m (32ft) maximum |
Safety Category Rating | CAT IV-600V, CAT III-1000V |
Electrical range specifications
Valid for ambient temperature conditions 18 to 28 ℃
Function | Range | Resolution | Accuracy (of reading) |
---|---|---|---|
AC current | 400,0 A | 0,1 A | ± (2,5% + 8 digits) |
1000 A | ± (2,8% + 5 digits) | ||
DC current | 400,0 A | 0,1 A | ± (2,5% + 5 digits) |
1000 A | ± (2,8% + 5 digits) | ||
AC voltage | 400,0 mV | 0,1 mV | ± (1,5% + 10 digits) |
4,000 V | 0,001 V | ± (1,5% + 5 digits) | |
40,00 V | 0,01 V | ||
400,0 V | 0,1 V | ||
1000 V | 1 V | ± (2,0% + 5 digits) | |
NOTE |
|||
DC voltage | 400,0 mV | 0,1 mV | ± (1,5%+10 digits) |
4,000 V | 0,001 V | ± (1,5% + 2 digits) | |
40,00 V | 0,01 V | ||
400,0 V | 0,1 V | ||
1000 V | 1 V | ± (2,0% + 2 digits) | |
Resistance | 400,0 Ω | 0,1 Ω | ± (1,0% + 4 digits) |
4,000 kΩ | 0,001 kΩ | ± (1,5% + 2 digits) | |
40,00 kΩ | 0,01 kΩ | ||
400,0 kΩ | 0,1 kΩ | ||
4,000 MΩ | 0,001 MΩ | ± (2,5% + 3 digits) | |
40,00 MΩ | 0,01 MΩ | ± (3,5% + 5 digits) | |
Capacitance | 4,000 nF | 0,001 nF | ± (5,0% + 30 digits) |
40,00 nF | 0,01 nF | ± (5,0% + 20 digits) | |
400,0 nF | 0,1 nF | ± (3,0% + 5 digits) | |
4,000 μF | 0,001 μF | ||
40,00 μF | 0,01 μF | ||
400,0 μF | 0,1 μF | ± (4,0% + 10 digits) | |
4,000 mF | 0,001 mF | ± (10% + 10 digits) | |
40,00 mF | 0,01 mF | Unspecified | |
Frequency | 4,000 kHz | 0,001 kHz | ± (1,5% + 2 digits) |
Sensitivity:: 100 V (< 50 Hz); 50 V (50–400 Hz); 5 V (401–4000 Hz) |
Thermal range specifications
Function | Thermocouple range |
IR range | Accuracy (of reading) |
---|---|---|---|
IR temperature (8:1 ratio) |
-29 do -20℃(-20 do -4℉) | ± 5℃ | |
Od -20 do 270℃ | ±2.0% reading or ±2℃ (±4℉) (whichever is greater) |
||
Type K inputs (excluding probe) |
Od -20 do+120℃ | ±(3% rdg + 5℃) (±(3% rdg + 9℉) |
Maximumu input specifications
Function | Maximum input |
---|---|
AC voltage, DC voltage | 1000 V DC/AC |
Thermocouple | 1000 V DC/AC |
Resistance, capacitance, frequency, diode test | 1000 V DC/AC |
Вашу оцінку відгуку не було надіслано