

Ви повинні увійти в систему
Category
Montaż urządzeń
Modernizacja induktorów
Urządzenia indukcyjne
asd
Фотографії призначені тільки для інформаційних цілей. Подивитися специфікацію продукту
please use latin characters
Contact Load: | 15 (8)A 24-250V~, min. 150mA for 24V~ |
---|---|
Contact Type: | 1 microswitch as a potential-free contact |
Ambient Temperature: | -15…80°C |
Degree of Protection: | IP40 |
Protection Class: | I |
Sensor: | Filled with liquid, made of copper, active along its entire length |
Max. Sensor Temperature: | 200°C |
Color: | Gray |
Specially adapted as a minimum or maximum value thermostat for air inlet control or fan control in ventilation and air conditioning systems. It can also be used as an overheat thermostat in electric heating systems and gas or oil-fired heaters.
Type | Range | Hysteresis | Type* | Capillary Length | Equipment** |
---|---|---|---|---|---|
JTU-50 | -25…+65°C | 1.5 K | TW | 350 mm | |
JTU-1 | 20…100°C | 8…30 K | TW | 350 mm | Sparkproof / Cold Protection |
JTU-3 | 20…100°C | External Reset | STB | 350 mm | Sparkproof / Cold Protection |
JTU-20 | 20…100°C | External Reset | STB | 1,250 mm | Sparkproof / Cold Protection |
JTU-5 | 60…140°C | 8…30 K, adjustable | TW | 350 mm | |
JTU-6 | 60…140°C | External Reset | TB | 350 mm |
(*) TW = Temperature Monitor, STB = Temperature Safety Limiter, TB = Temperature Limiter
(**) Sparkproof / Cold Protection: The devices are resistant to damage, specifically, the burner is shut off if the sensor-filling medium leaks, for example, in the case of sensor damage. Since negative temperatures reduce the filling medium's volume, leading to a similar effect as sensor damage, the devices are adjusted using a "cold screw" so that the burner is turned off at temperatures below -15°C. They can be reset above approximately -5°C by pressing the reset button.
The device provides protection against uncontrolled overheating, which can be caused by the accumulation or gradual loss of the filling medium in the capillary tube due to invisible damage to the tube, etc. The sensor fuse blows when the temperature reaches 220°C, resulting in the deactivation of the device due to the loss of the filling medium in the capillary tube. After such an event, the burner cannot be reactivated, and the device is no longer suitable for use. It can only serve as a signal that the temperature has reached 220°C.
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
Contact Load: | 15 (8)A 24-250V~, min. 150mA for 24V~ |
---|---|
Contact Type: | 1 microswitch as a potential-free contact |
Ambient Temperature: | -15…80°C |
Degree of Protection: | IP40 |
Protection Class: | I |
Sensor: | Filled with liquid, made of copper, active along its entire length |
Max. Sensor Temperature: | 200°C |
Color: | Gray |
Specially adapted as a minimum or maximum value thermostat for air inlet control or fan control in ventilation and air conditioning systems. It can also be used as an overheat thermostat in electric heating systems and gas or oil-fired heaters.
Type | Range | Hysteresis | Type* | Capillary Length | Equipment** |
---|---|---|---|---|---|
JTU-50 | -25…+65°C | 1.5 K | TW | 350 mm | |
JTU-1 | 20…100°C | 8…30 K | TW | 350 mm | Sparkproof / Cold Protection |
JTU-3 | 20…100°C | External Reset | STB | 350 mm | Sparkproof / Cold Protection |
JTU-20 | 20…100°C | External Reset | STB | 1,250 mm | Sparkproof / Cold Protection |
JTU-5 | 60…140°C | 8…30 K, adjustable | TW | 350 mm | |
JTU-6 | 60…140°C | External Reset | TB | 350 mm |
(*) TW = Temperature Monitor, STB = Temperature Safety Limiter, TB = Temperature Limiter
(**) Sparkproof / Cold Protection: The devices are resistant to damage, specifically, the burner is shut off if the sensor-filling medium leaks, for example, in the case of sensor damage. Since negative temperatures reduce the filling medium's volume, leading to a similar effect as sensor damage, the devices are adjusted using a "cold screw" so that the burner is turned off at temperatures below -15°C. They can be reset above approximately -5°C by pressing the reset button.
The device provides protection against uncontrolled overheating, which can be caused by the accumulation or gradual loss of the filling medium in the capillary tube due to invisible damage to the tube, etc. The sensor fuse blows when the temperature reaches 220°C, resulting in the deactivation of the device due to the loss of the filling medium in the capillary tube. After such an event, the burner cannot be reactivated, and the device is no longer suitable for use. It can only serve as a signal that the temperature has reached 220°C.
Вашу оцінку відгуку не було надіслано
Поскаржитись на відгук
Скаргу надіслано
Ваш відгук не надіслано
Написати свій відгук
Відгук надіслано
Ваш відгук не надіслано