Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. These filter fans are intended for indoor use. The plastic used for the hood is highly UV light resistant.
Axial fan, ball bearing |
service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor metal |
Connection |
3-pole clamp for 2.5mm², clamping torque 0.8Nm max. |
Casing (filter fan and exit filter) | plastic according to UL94 V-0, light grey |
Mounting frame | with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); a template for the enclosure cut-out is included in the delivery of the filter fans |
Filter mat | G4 acc. to DIN EN 779, filtering degree 94% |
Filter material |
synthetic fibre with progressive construction, temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH, |
Operating/Storage temperature | - 45°C - +70°C |
Protection type | IP54* /1 (with protective conductor) |
Air flow sensor built into the grille that protects the toes fan fltrem. np. art.nr 21804.0-00 |
![]() |
Art. No. | Operating voltage | Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
approvals |
---|---|---|---|---|---|---|---|---|---|---|
01804.0-00 |
AC230V, 50 Hz | 200 m³/h | 125m³/h | 320 mA | 45 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg | UL File No. E234324 |
01804.0-01 |
AC120V, 60 Hz* | 200 m³/h | 125m³/h | 470 mA | 39 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg | UL File No. E234324 |
Art. No | Depth in enclosure | Enclosure cut-out | Weight (approx.) | Filter mat | Protection type |
---|---|---|---|---|---|
11802.0-00 |
16 mm | 176x176 mm+ 0,4 | 0,60 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
The filter cartridge 168x168 mm | |
---|---|
G4 (1 packing unit = 3 pcs.) | Nr. art. 08602.0-00 |
F5 (1 packaging unit = 3 pcs.) | Nr. art. 08605.0-00 |
Art. No | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out | Weight (approx.) |
---|---|---|---|---|---|---|---|---|---|
21804.0-00 |
AC230V, 50 Hz | 200 m³/h | 125m³/h | 320 mA | 45 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg |
21804.0-01 |
AC120V, 60Hz* | 200 m³/h | 125m³/h | 470 mA | 39 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg |
Ви зацікавлені у цьому продукті? Вам потрібна додаткова інформація або індивідуальні розцінки?
Ви повинні увійти в систему
|
![]() |
Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. These filter fans are intended for indoor use. The plastic used for the hood is highly UV light resistant.
Axial fan, ball bearing |
service life 50,000h at +25°C (+77°F), 65% RH fan body aluminium, rotor metal |
Connection |
3-pole clamp for 2.5mm², clamping torque 0.8Nm max. |
Casing (filter fan and exit filter) | plastic according to UL94 V-0, light grey |
Mounting frame | with double-sided industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); a template for the enclosure cut-out is included in the delivery of the filter fans |
Filter mat | G4 acc. to DIN EN 779, filtering degree 94% |
Filter material |
synthetic fibre with progressive construction, temperature resistant to +100°C, self-extinguishing class F1, moisture resistant to 100% RH, |
Operating/Storage temperature | - 45°C - +70°C |
Protection type | IP54* /1 (with protective conductor) |
Air flow sensor built into the grille that protects the toes fan fltrem. np. art.nr 21804.0-00 |
![]() |
Art. No. | Operating voltage | Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out |
Weight (approx.) |
approvals |
---|---|---|---|---|---|---|---|---|---|---|
01804.0-00 |
AC230V, 50 Hz | 200 m³/h | 125m³/h | 320 mA | 45 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg | UL File No. E234324 |
01804.0-01 |
AC120V, 60 Hz* | 200 m³/h | 125m³/h | 470 mA | 39 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg | UL File No. E234324 |
Art. No | Depth in enclosure | Enclosure cut-out | Weight (approx.) | Filter mat | Protection type |
---|---|---|---|---|---|
11802.0-00 |
16 mm | 176x176 mm+ 0,4 | 0,60 kg | G4 acc. to DIN EN 779, filtering degree 94% | IP54* |
The filter cartridge 168x168 mm | |
---|---|
G4 (1 packing unit = 3 pcs.) | Nr. art. 08602.0-00 |
F5 (1 packaging unit = 3 pcs.) | Nr. art. 08605.0-00 |
Art. No | Operating voltage |
Air volume, free flow |
Air volume with exit filter |
Current consumption |
Power consumption |
Average noise level (DIN EN ISO 4871) |
Depth in enclosure |
Enclosure cut-out | Weight (approx.) |
---|---|---|---|---|---|---|---|---|---|
21804.0-00 |
AC230V, 50 Hz | 200 m³/h | 125m³/h | 320 mA | 45 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg |
21804.0-01 |
AC120V, 60Hz* | 200 m³/h | 125m³/h | 470 mA | 39 W | 52 dB (A) | 95 mm | 176x176 mm+ 0,4 | 1,70 kg |